Fluke 106 Palm-sized Digital Multimeter

  • Compact and Portable Design: Easy to carry and use.
  • True-RMS AC Voltage and Current Measurement: Ensures accurate measurements on complex waveforms.
  • Large, Backlit Display: Clear visibility in low-light conditions.
  • Auto and Manual Ranging: Flexible measurement settings.
  • Diode Test: Tests various types of diodes.
  • Continuity Test: Identifies continuity and open circuits.
  • Safety Rating: CAT III 600V safety rating.

Description

The Fluke 106 is a compact and reliable digital multimeter designed to fit in the palm of your hand and go with you wherever your work takes you. It’s perfect for everyday electrical testing tasks, offering essential features in a convenient package.

Key Features:

  • Compact and Portable: Its small size and lightweight design make it easy to carry and use in various settings.
  • True-RMS AC Voltage and Current: Ensures accurate measurements on complex waveforms, including non-sinusoidal signals.
  • Large, Backlit Display: Provides clear visibility of readings, even in low-light conditions.
  • Auto and Manual Ranging: Offers flexibility in measurement settings.
  • Diode Test: Tests various types of diodes.
  • Continuity Test: Identifies continuity and open circuits.
  • Safety Rating: CAT III 600V safety rating for safe operation in various electrical environments.

Applications:

  • Electrical Installation and Maintenance: Verifying voltage, current, and resistance in electrical systems.
  • HVAC Systems: Troubleshooting HVAC equipment, such as motors, compressors, and fans.
  • Automotive Diagnostics: Testing battery voltage, alternator output, and starter motor current.
  • Home and Building Inspections: Checking electrical outlets, switches, and wiring.

The Fluke 106 is a reliable and versatile multimeter that can handle a wide range of basic electrical testing tasks. Its compact size, user-friendly interface, and essential features make it a valuable tool for professionals and DIY enthusiasts alike.

Additional information

Brand

Fluke

Specifications: Fluke 106 Palm-sized Digital Multimeter

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications
Function Range Resolution Accuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance2 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency3 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle3 1 % to 99 % 0.1 % NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  3. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
50 Hz or 60 Hz
−
\AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz −
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

 

Models: Fluke 106 Palm-sized Digital Multimeter
Includes:

  • Fluke 106 Palm-sized Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • 2 AAA Batteries (Installed)
  • User’s Manual

Related Products