Fluke 115 Field Technicians Digital Multimeter
- True RMS AC Voltage and Current Measurement: Ensures accurate readings for non-sinusoidal waveforms.
- High Resolution and Accuracy: 6000-count display for precise measurements.
- Rugged Construction: Durable design for tough environments.
- Safety Rating: CAT III 600V for safe operation.
- Auto Ranging: Automatic range selection for convenience.
- Backlit Display: Easy readability in low-light conditions.
- Min/Max Recording: Captures minimum and maximum readings.
- Hold Function: Freezes readings for analysis.
- Low-Pass Filter: Reduces noise and interference.
- Fast Continuity Check: Quick identification of open or short circuits.
- Diode Test: Measures forward voltage drop of diodes.
- Capacitance Measurement: Measures capacitance values.1
- Description
- Additional information
- Specifications
- Models
Description
The Fluke 115 is a robust and reliable digital multimeter, designed to handle the demands of professional electricians and DIY enthusiasts alike. It’s a versatile tool that combines accuracy, durability, and essential features to streamline troubleshooting and maintenance tasks.
Key Features:
- True RMS AC Voltage and Current Measurement: Ensures accurate readings even for complex, non-sinusoidal waveforms, making it ideal for modern electrical systems.
- High Resolution and Accuracy: The 6000-count display provides precise measurements, allowing for detailed analysis of electrical parameters.
- Rugged Construction: Built to withstand tough working conditions, including drops and shocks.
- Safety Rating: Meets stringent safety standards (CAT III 600V) for safe operation in demanding environments.
- Auto Ranging: Automatically selects the appropriate measurement range for optimal accuracy and convenience.
- Backlit Display: Ensures easy readability in low-light conditions.
- Min/Max Recording: Captures minimum and maximum readings for trend analysis.
- Hold Function: Freezes readings on the display for easy analysis.
- Low-Pass Filter: Reduces noise and interference for cleaner measurements.
- Fast Continuity Check: Quickly identifies open or short circuits.
- Diode Test: Measures forward voltage drop of diodes.
- Capacitance Measurement: Measures capacitance values.
The Fluke 115 is a versatile tool that can be used in a wide range of applications, including:
- Electrical Maintenance: Troubleshooting electrical panels, motor controls, and power distribution systems.
- HVAC Systems: Diagnosing and repairing HVAC equipment.
- Automotive and Aerospace: Testing electrical components and systems.
- General Electronics: Troubleshooting and repairing electronic devices.
With its combination of features, durability, and accuracy, the Fluke 115 is a trusted tool for professionals who demand reliable and precise measurements.
Additional information
Brand | Fluke |
---|
Specifications: Fluke 115 Field Technicians Digital Multimeter
Specifications | ||
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1Â True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts1Â True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500Hz) |
Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A overload for 30-seconds max |
|
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A overload for 30-seconds max |
|
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉. |
General Specifications | |
Maximum voltage between any terminal and earth ground | 600 V |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
Display | Digital: 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating temperature | -10℃ to + 50℃ |
Storage temperature | -40℃ to + 60℃ |
Battery type | 9 volt Alkaline, IEC 6LR61 |
Battery life | 400 hours typical, without backlight |
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight | 550 g |
Models: Fluke 115 Field Technicians Digital Multimeter
Includes:
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- User manual