- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
- Dual-zone control
- Full HART field communicator
- Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
- Set point control by reference
- Self-calibration feature
- ISO 17025-accredited calibration w/data included
- 5608: –200 °C to 500 °C (80 mm minimum immersion)
- 5609: –200 °C to 670 °C (100 mm minimum immersion)
- ± 0.01 short-term stability
- Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
- Dry-well reference with 90 ° bend
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
- Portability: Remains compact and portable, allowing for on-site calibrations at various locations.
- Accuracy to ±0.25°C and comes with an RS-232 interface.
- The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
- The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
- Features designed with user convenience and productivity in mind.
- Highly accurate thermo hygrometer and humidity monitor.
- Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
- Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
- Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
- Temperature control from 100°C to 1210°C
- Two models to choose from: Reference (ADT878) and Standard (ADT875)
- Display Accuracy of ±1.5°C (ADT878)
- 4 on-board measurement channels (PC option)
- Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
- ISO 17025-accredited calibration w/data included
- Most stable temperature controllers available
- Resolution as high as 0.00018°C
- RS-232 interface included for automating applications