- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
- Complete pressure, temperature, and mA loop calibrator
- Troubleshoot and calibrate HART smart digital transmitters
- Create calibration procedures and automatically document results
- Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
- Every ITS-90 fixed point available from argon to copper
- Plateaus last days (gallium for weeks and TPW for months).
- Accredited Cell Intercomaparisons available.
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
- Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
- Powerful, easy-to-use, high-accuracy temperature calibrator
- Test and calibrate temperature sensors and transmitters
- Measures 4 to 20 mA loops and can provide loop power
- Measures RTDs, thermocouples, ohms, and volts
- Source/simulates thermocouples, RTDs, volts, and ohms
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
- Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
- Scan up to 10 channels per second, great for high-speed applications.
- Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
- Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.