• Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months).
  • Accredited Cell Intercomaparisons available.

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.

  • World’s smallest portable calibration baths.
  • Calibrates sensors of any size or shape.
  • Stability to ±0.015 °C.
  • Ranges from –30 °C to 200 °C.

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Displays temperature in °C or °F

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

  • Wide temperature range: –95 °C to 140 °C.
  • Excellent accuracy
  • Accuracy using built-in reference thermometer readout: ± 0.05 °C full range.
  • Display accuracy: ± 0.2 °C full range.
  • Best-in-class stability: ± 0.015 °C full range