• Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Most stable temperature controllers available
  • Resolution as high as 0.00018°C
  • RS-232 interface included for automating applications

  • Accredited radiometric calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.

  • Highly accurate thermo hygrometer and humidity monitor.
  • Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
  • Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
  • Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
  • Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
  • Scan up to 10 channels per second, great for high-speed applications.
  • Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
  • Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

  • Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
  • Display eight user-selected data fields from any channel.
  • Log up to 8,000 readings with date and time stamps for data tracking.

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend