Fluke 725Ex Series Process Calibrator

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

Fluke P3000 Pneumatic Deadweight Testers

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

Fluke 721Ex Precision Pressure Calibrator

  • Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
  • Ideal for gas flow calibration (custody transfer) applications
  • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
  • Pt100 RTD input for temperature measurement, (probe optional)

Additel ADT762 Automated Hydraulic Pressure Calibrator

  • Automated pressure generation and control to 15,000 psi (1035 Bar)
  • Accuracy to 0.01%FS
  • Dual-range calibration
  • Control stability ≤ 0.005%FS
  • Data logging and task management
  • Patented electric pump technology
  • ISO 17025-accredited calibration w/data included

Fluke P5514B Hydraulic Pressure Comparator

  • Easily generate pressure to 10 000 psi (70 MPa)
  • Vernier fine adjustment control
  • Tool-free test connectors for easy, leak free connections
  • Test port connectors include adaptors for common sizes of NPT and BSP

Fluke 718Ex Intrinsically Safe Pressure Calibrator

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.

Fluke 3130-G2M Portable Pressure Calibrator

  • Measure/generate pressures from vacuum to 2 MPa (300 psi, 20 bar).
  • Measure/generate 4 to 20 mA, measures 0 to 30 V DC
  • Generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar).
  • External gas supply up to 2 MPa (300 psi, 20 bar).
  • Fine pressure adjustment.
  • Measurement accuracy of ± (0.025 % reading + 0.01 % FS).

, , ,

Fluke 725 Multifunction Process Calibrator

  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply

Fluke P3100 Hydraulic Deadweight Testers

  • Pressure ranges to 60,000 psi (4000 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston format
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC