Fluke 725Ex Series Process Calibrator
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
Fluke P3000 Pneumatic Deadweight Testers
- 0.015% of reading accuracy standard (0.008% optional)
- 1-30 inHg vacuum (0.03-1 bar vacuum)
- 3-500 psi (0.2-35 bar) pressure
- inH2O and mbar ranges available
- Series 3 non-magnetic stainless steel weights
- Units can be trimmed to local gravity FOC
Fluke 721Ex Precision Pressure Calibrator
- Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
- Ideal for gas flow calibration (custody transfer) applications
- Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
- Pt100 RTD input for temperature measurement, (probe optional)
Additel ADT762 Automated Hydraulic Pressure Calibrator
- Automated pressure generation and control to 15,000 psi (1035 Bar)
- Accuracy to 0.01%FS
- Dual-range calibration
- Control stability ≤ 0.005%FS
- Data logging and task management
- Patented electric pump technology
- ISO 17025-accredited calibration w/data included
Fluke P5514B Hydraulic Pressure Comparator
- Easily generate pressure to 10 000 psi (70 MPa)
- Vernier fine adjustment control
- Tool-free test connectors for easy, leak free connections
- Test port connectors include adaptors for common sizes of NPT and BSP
Fluke 718Ex Intrinsically Safe Pressure Calibrator
- ATEX II 1G Ex ia IIC T4 Compliant.
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
- Current measurement with 0.02% accuracy and 0.001 mA resolution.
Fluke 3130-G2M Portable Pressure Calibrator
- Measure/generate pressures from vacuum to 2 MPa (300 psi, 20 bar).
- Measure/generate 4 to 20 mA, measures 0 to 30 V DC
- Generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar).
- External gas supply up to 2 MPa (300 psi, 20 bar).
- Fine pressure adjustment.
- Measurement accuracy of ± (0.025 % reading + 0.01 % FS).
Fluke 725 Multifunction Process Calibrator
- Calibration of both temperature and pressure transmitters
- Measure/source/simulate mA loop parameters
- Measure and source mA, Volts DC, frequency, and resistance
- Built-in 24 V loop power supply
Fluke P3100 Hydraulic Deadweight Testers
- Pressure ranges to 60,000 psi (4000 bar)
- 0.015% of reading accuracy standard (0.008% optional)
- Single or dual piston format
- Built-in hand pumps standard
- Mounted spirit level with adjustable feet
- Units can be trimmed to local gravity FOC