Fluke 718 Pressure Calibrator

  • Pressure Source and mA Measurement to calibrate pressure devices
  • Built-in pump for sourcing pressure to 300 PSI
  • Easy-to-clean, field-serviceable, integrated pressure pump
  • Built-in switch test for calibrating pressure switches
  • Extend pressure capabilities by using Fluke 750P pressure modules

Fluke P5510-2700G & P5513-2700G Pressure Calibrators

  • 0.02% full scale accuracy per 2700G Gauge.
  • Adaptors for NPT, BSP, and metric fittings.
  • Expandable lower range with additional gauges.
  • Battery-operated gauges with line power capability.

, , ,

Fluke 725 Multifunction Process Calibrator

  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply

Fluke 6531 and 6532 E-DWT Electronic Deadweight Tester Kits

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty.

, , ,

Fluke 726 Precision Multifunction Calibrators

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply

Additel ADT760 Automatic Handheld Pressure Calibrator

  • Accuracy as low as 0.01%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • ISO 17025-accredited calibration w/data included

, , ,

Fluke 754 Documenting Process Calibrator-HART

  • Complete pressure, temperature, and mA loop calibrator
  • Troubleshoot and calibrate HART smart digital transmitters
  • Create calibration procedures and automatically document results

, , ,

Fluke 753 Documenting Process Calibrator

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

Fluke P3100 Hydraulic Deadweight Testers

  • Pressure ranges to 60,000 psi (4000 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston format
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC