- Resolution: ±12,000 digits, 4½-place
- Basic accuracy: ±0.05% (VDC)
- Voltage ACTRMS, voltage AC+DCTRMS, voltage DC, frequency (Hz, kHz), resistance, diode test, continuity test, current ACTRMS, current AC+DCTRMS, temperature with type K thermocouples
- Measuring category: 600 V CAT IV, 1000 V CAT III
- Offers true-RMS AC voltage and current for measuring non-linear signals
- Captures intermittents as short as 250 µS
- Safety rated CAT III 1000 V, CAT IV 600 V
- Includes a built-in thermometer and temperature probe
- Frequency measurement up to 1 MHz.
- CAT IV / 1000 V overvoltage protection.
- Large bright 4 digits 9999 counts dual LCD display.
- Basic dc accuracy 0.5%
- CAT III 600 V safety rated
- Diode and continuity test with buzzer
- TRMS accurate readings on sinusoidal and non-sinusoidal signals.
- PI/DAR feature.
- CAT IV / 600 V and CAT III / 1000 V overvoltage protection.
- Free your hands with the optional TPAK magnetic hanger
- Auto and Manual ranging
- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
- VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
- Large backlit display
- CAT IV 600 V safety rated
- Resolution: ±60,000 digits, 4 6/7-place
- Basic accuracy: ±0.05% (VDC)
- Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, resistance, diode testing, continuity test, capacitance, current
- Measuring category: 600 V CAT IV, 1000 V CAT III
- Measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
- Crest (instantaneous peak) capture mode catches 5 ms long peaks.
- Safety: CAT III / 1000 V overvoltage protection.
- Features manual and automatic ranging
- Safety rates CAT III 600 V
- Fits into optional ToolPak™ magnetic hanger for hands-free operation
- TRMS accurate readings on sinusoidal and non-sinusoidal signals.
- CAT IV / 1000 V overvoltage protection.
- Large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.
- Resolution: ±310,000 digits, 5¾-place
- Basic accuracy: ±0.02% (VDC)
- Measuring category: 300 V CAT IV, 600 V CAT III
- Includes built-in thermometer
- Microamps to test flame sensors
- CAT III 600 V safety rated”” For HVAC technicians, building maintenance
- Measure up to 1000 V AC and DC
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 μF capacitance range
- Frequency to 200 kHz
- Resolution: ±310,000 digits, 5¾-place
- Basic accuracy: ±0.02% (VDC)
- Voltage DC, ACTRMS, AC+DC TRMS, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, current DC, ACTRMS, AC+DCTRMS, resistance, diode testing, continuity test, capacitance, temperature with Pt 100/1000 sensors and type K thermocouples
- Measuring category: 300 V CAT IV, 600 V CAT III
- Non-contact and probe-contact electric field detection.
- Protected against wrong connection and overvoltage (CAT III / 300 V and CAT II / 600 V).
- LCD display, 3-5/6 digits, 6000 counts
- Resolution: ±12,000 digits, 4½-place
- Basic accuracy: ±0.05% (VDC)
- Voltage ACTRMS, voltage AC+DCTRMS, voltage DC, frequency (Hz, kHz), resistance, diode test, continuity test, capacitance, current ACTRMS, current AC+DCTRMS, temperature with type K thermocouples
- Measuring category: 600 V CAT IV, 1000 V CAT III
- CAT III 600 V safety rating
- Current and voltage measurements
- Measures resistance and continuity to check for broken wires
- A completely sealed, IP67 rated case
- Withstands drops up to 10 ft or 3 m (with holster)
- Dustproof per IEC 60529 IP6x
- Waterproof per IEC 60529 IPx7
- CAT III 1000 V, CAT IV 600 V
- Resolution: ±60,000 digits, 4 6/7-place
- Basic accuracy: ±0.05% (VDC)
- VCTRMS, current AC+DCTRMS, temperature with Pt 100/1000 sensors and type K thermocouples
- Measure up to 1000 V AC and DC
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 μF capacitance range
- Frequency to 200 kHz
- Built-in thermometer to measure temperature without having to carry a separate instrument
- Accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
- Safety rated CAT III 1000 V, CAT IV 600 V
- Measure safely with CAT III 1500 V/CAT IV 1000 V safety rated multimeter
- Includes TL175-HV CAT III 1500 V/CAT IV 1000 V safety rated premium test leads
- User-defined limit gauge for quick go/no-go decisions
- True-RMS AC Voltage and Current Measurement
- Measures capacitance values.
- CAT III 1000V / CAT IV 600V safety rating for demanding environments.
- Safety rated CAT III 1000 V, CAT IV 600 V
- Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
- This electrical multimeter correctly measure pulse-width modulated motor drive signals
- True-RMS AC voltage and current for accurate measurements on complex signals or non-linear loads. AC bandwidth specified to 100 kHz.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
- Temperature function.
- AC and DC voltage measurement
- AC and DC current measurement
- Resistance measurement
- Capacitance measurement
- Features True RMS capabilities for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average to record signal fluctuations
- Non-contact and probe contact electric field detection.
- Test results can be downloaded to the computer via the optional PC software.
- CAT II / 1000 V, CAT III / 600 V and CAT IV / 300 V overvoltage protection.
- TRMS measurement up to 20 kHz with digital display (60,000 digits) and analog scale
- Measurement of voltage and current, DC, AC and AC+DC, dB, resistance, capacitance, temperature, frequency, continuity/diodes
- CAT IV up to 600 V and CAT III up to 1000 V.
- True-RMS AC voltage and current for accurate measurements on non-linear signals.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
- Peak capture to record transients as fast as 250 μs.
- Resolution: ± 12,000 digits, 4½-place
- 3 connector jacks with patented automatic blocking sockets (ABS)
- TRMS AC and AC / DC function
- Voltage measurement with a basic accuracy of ±0.05% (V DC)