• Resolution: ±12,000 digits, 4½-place
  • Basic accuracy: ±0.05% (VDC)
  • Voltage ACTRMS, voltage AC+DCTRMS, voltage DC, frequency (Hz, kHz), resistance, diode test, continuity test, current ACTRMS, current AC+DCTRMS, temperature with type K thermocouples
  • Measuring category: 600 V CAT IV, 1000 V CAT III

  • Offers true-RMS AC voltage and current for measuring non-linear signals
  • Captures intermittents as short as 250 µS
  • Safety rated CAT III 1000 V, CAT IV 600 V
  • Includes a built-in thermometer and temperature probe

  • Frequency measurement up to 1 MHz.
  • CAT IV / 1000 V overvoltage protection.
  • Large bright 4 digits 9999 counts dual LCD display.

  • Basic dc accuracy 0.5%
  • CAT III 600 V safety rated
  • Diode and continuity test with buzzer

  • TRMS accurate readings on sinusoidal and non-sinusoidal signals.
  • PI/DAR  feature.
  • CAT IV / 600 V and CAT III / 1000 V overvoltage protection.

  • Free your hands with the optional TPAK magnetic hanger
  • Auto and Manual ranging
  • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards

  • VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
  • Large backlit display
  • CAT IV 600 V safety rated

  • Resolution: ±60,000 digits, 4 6/7-place
  • Basic accuracy: ±0.05% (VDC)
  • Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, resistance, diode testing, continuity test, capacitance, current
  • Measuring category: 600 V CAT IV, 1000 V CAT III

  • Measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
  • Crest (instantaneous peak) capture mode catches 5 ms long peaks.
  • Safety: CAT III / 1000 V overvoltage protection.

  • Features manual and automatic ranging
  • Safety rates CAT III 600 V
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation

  • TRMS accurate readings on sinusoidal and non-sinusoidal signals.
  • CAT IV / 1000 V overvoltage protection.
  • Large bright 4 digits 500.000 counts dual LCD display with backlight for working in dark conditions.

  • Resolution: ±310,000 digits, 5¾-place
  • Basic accuracy: ±0.02% (VDC)
  • Measuring category: 300 V CAT IV, 600 V CAT III

  • Includes built-in thermometer
  • Microamps to test flame sensors
  • CAT III 600 V safety rated”” For HVAC technicians, building maintenance

  • Measure up to 1000 V AC and DC
  • Measure up to 10 A (20 A for 30 seconds)
  • 10,000 μF capacitance range
  • Frequency to 200 kHz

  • Resolution: ±310,000 digits, 5¾-place
  • Basic accuracy: ±0.02% (VDC)
  • Voltage DC, ACTRMS, AC+DC TRMS, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, current DC, ACTRMS, AC+DCTRMS, resistance, diode testing, continuity test, capacitance, temperature with Pt 100/1000 sensors and type K thermocouples
  • Measuring category: 300 V CAT IV, 600 V CAT III

  • Non-contact and probe-contact electric field detection.
  • Protected against wrong connection and overvoltage (CAT III / 300 V and CAT II / 600 V).
  • LCD display, 3-5/6 digits, 6000 counts

  • Resolution: ±12,000 digits, 4½-place
  • Basic accuracy: ±0.05% (VDC)
  • Voltage ACTRMS, voltage AC+DCTRMS, voltage DC, frequency (Hz, kHz), resistance, diode test, continuity test, capacitance, current ACTRMS, current AC+DCTRMS, temperature with type K thermocouples
  • Measuring category: 600 V CAT IV, 1000 V CAT III

  • CAT III 600 V safety rating
  • Current and voltage measurements
  • Measures resistance and continuity to check for broken wires

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 ft or 3 m (with holster)
  • Dustproof per IEC 60529 IP6x
  • Waterproof per IEC 60529 IPx7
  • CAT III 1000 V, CAT IV 600 V

  • Resolution: ±60,000 digits, 4 6/7-place
  • Basic accuracy: ±0.05% (VDC)
  • VCTRMS, current AC+DCTRMS, temperature with Pt 100/1000 sensors and type K thermocouples

  • Measure up to 1000 V AC and DC
  • Measure up to 10 A (20 A for 30 seconds)
  • 10,000 μF capacitance range
  • Frequency to 200 kHz

  • Built-in thermometer to measure temperature without having to carry a separate instrument
  • Accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
  • Safety rated CAT III 1000 V, CAT IV 600 V

  • Measure safely with CAT III 1500 V/CAT IV 1000 V safety rated multimeter
  • Includes TL175-HV CAT III 1500 V/CAT IV 1000 V safety rated premium test leads
  • User-defined limit gauge for quick go/no-go decisions

  • True-RMS AC Voltage and Current Measurement
  • Measures capacitance values.
  • CAT III 1000V / CAT IV 600V safety rating for demanding environments.

  • Safety rated CAT III 1000 V, CAT IV 600 V
  • Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
  • This electrical multimeter correctly measure pulse-width modulated motor drive signals

  • True-RMS AC voltage and current for accurate measurements on complex signals or non-linear loads. AC bandwidth specified to 100 kHz.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.
  • Temperature function.

  • AC and DC voltage measurement
  • AC and DC current measurement
  • Resistance measurement
  • Capacitance measurement

  • Features True RMS capabilities for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations

  • Non-contact and probe contact electric field detection.
  • Test results can be downloaded to the computer via the optional PC software.
  • CAT II / 1000 V, CAT III / 600 V and CAT IV / 300 V overvoltage protection.

  • TRMS measurement up to 20 kHz with digital display (60,000 digits) and analog scale
  • Measurement of voltage and current, DC, AC and AC+DC, dB, resistance, capacitance, temperature, frequency, continuity/diodes
  • CAT IV up to 600 V and CAT III up to 1000 V.

  • True-RMS AC voltage and current for accurate measurements on non-linear signals.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.
  • Peak capture to record transients as fast as 250 μs.

  • Resolution: ± 12,000 digits, 4½-place
  • 3 connector jacks with patented automatic blocking sockets (ABS)
  • TRMS AC and AC / DC function
  • Voltage measurement with a basic accuracy­ of ±0.05% (V DC)