Gossen METRAHIT PM TUNE High-end TRMS Multimeter
- 26 multimeter functions
- Resolution: ±60,000 digits, 4 6/7-place
- Basic accuracy: ±0.05% (VDC)
- Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, resistance, diode testing, continuity test, capacitance, current
- ACTRMS, current AC+DCTRMS, temperature with Pt 100/1000 sensors and type K thermocouples
- Auto-ranging current measurement from 10 nA to 10 A (16 A) via a single connector jack and a single fuse
- Clip function for TRMS current measurement with sensors and transformers
- Additional filter function and voltage measurement with reduced input impedance for limiting interference, e.g. for measurements at frequency converters
- Automatic and manual measuring range selection
- Zero adjustment
- Automatic storage of measured values: DATA / MIN / MAX
- 2 MB data memory for 61,600 measured values for long-term measurements with data logger function
- Infrared interface for communication with the PC
- Large, light-blue illuminated display with extra-large characters (15 mm) and an analog bar graph for dynamic processes
- Separate battery and fuse compartments
- Power pack connector socket for operation without batteries
- Patented automatic blocking sockets (ABS)
- Measuring category: 600 V CAT IV, 1000 V CAT III
- Rubber holster for protection against shocks and impacts
- Description
- Additional information
- Specifications
Description
The Metrahit PM TUNE is a high-end, professional digital multimeter from the Metrahit Professional Multimeter series by Gossen Metrawatt. It’s specifically designed for tuning and adjustment tasks in various electrical and electronic applications.
Key Features:
- The increased refresh-rate of the LCD reacts directly and without time delay to changed adjustments, e.g. of a potentiometer
- Universal use in all fields of electrical engineering!
- TRMS measurement up to 100 kHz with digital display (60,000 digits) and analog scale
- Measurement of voltage and current, DC, AC and AC/DC, dB, ΔREL, resistance, temperature, frequency, duty cycle, capacitance, continuity/diodes
- Automatic measuring range selection and measured value storage
- Safety for the user and the instrument in measuring categories CAT IV up to 600 V and CAT III up to 1000 V.
- High Accuracy & Resolution: Offers exceptional measurement accuracy and high resolution for precise readings.
- Fast Response Time: Features a fast response time, crucial for tuning and adjusting sensitive circuits.
Benefits:
- Enhanced Tuning Accuracy: Enables precise adjustments and calibrations in various electronic and electrical systems.
- Improved Efficiency: Fast response time and high accuracy streamline tuning and troubleshooting processes.
- Increased Productivity: Enables faster and more efficient work in applications requiring precise measurements.
- Enhanced Reliability: Robust construction ensures reliable performance in demanding environments.
Applications:
- Precise tuning and adjustment of electronic circuits
- Audio and video equipment servicing
- Industrial automation and control systems
- Research and development
- Any application where high accuracy and fast response times are critical
The Metrahit PM TUNE is a specialized multimeter designed for professionals who require the highest levels of accuracy and performance in their measurements. Its fast response time, high resolution, and rugged construction make it an ideal tool for demanding tuning and adjustment tasks.
Additional information
Brand | Gossen Metrawatt |
---|
Characteristic Values
METRAHIT PM TECH | METRAHIT PM PRIME BT | METRAHIT PM XTRA | METRAHIT PM TUNE | METRAHIT PM PRIME | |
Item number | M253A | M248B | M250A | M250T | M248A |
Display | |||||
Indication | Analogue/digital | Digital | Analogue/digital | Analogue/digital | Digital |
Indication digits | 60000 | 310000 | 60000 | 60000 | 310000 |
Multiple display | x | x | |||
Measuring range selection | Manual/automatic | Manual/automatic | Manual/automatic | Manual/automatic | Manual/automatic |
Basic data | |||||
Type of measurement | TRMS | TRMS | TRMS | TRMS | TRMS |
True RMS measurement | x | x | x | x | x |
Basic accuracy | 0.05Percentage | 0.02Percentage | 0.05Percentage | 0.05Percentage | 0.02Percentage |
Measuring circuit category | CAT IV | CAT IV | CAT IV | CAT IV | CAT IV |
Max. voltage measuring circuit category | 600Volt | 300Volt | 600Volt | 600Volt | 300Volt |
Relative value measurement | x | x | x | x | x |
Min. value storage | x | x | x | x | x |
Max. value storage | x | x | x | x | x |
Peak value memory | |||||
Data hold | x | x | x | x | x |
Special functions | |||||
Explosion-tested version | |||||
Power and energy measurement | |||||
Harmonics analysis/power quality | |||||
Crest factor measurement | |||||
Rotational speed measuring | |||||
Duty cycle measurements | x | x | x | x | |
Pulse freqency measurement MHz @ 5V TTL | x | x | x | x | |
Inductance measurement | |||||
Interturn short-circuit high-voltage test | |||||
Automatic circuit breaker | |||||
Voltage measurement | |||||
Voltage measurement types | DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC AC+DC Fil |
DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC AC+DC Fil |
With decibel measurement (dB) | x | x | x | x | x |
Voltage measuring range DC | 0,00001Volt – 1000Volt | 0,000001Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 0,000001Volt – 600Volt |
Voltage measuring ranges DC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, DC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution, DC voltage | 0.01 mV | 0.001 mV | 0.01 mV | 0.01 mV | 0.001 mV |
Internal resistance volt DC | 9 | 10 | 9 | 9 | 10 |
Voltage measuring range AC | 0,00001Volt – 1000Volt | 1Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 1Volt – 600Volt |
Voltage measuring ranges AC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, AC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution, AC voltage | 0.01 mV | 0.01 mV | 0.01 mV | 0.01 mV | 0.01 mV |
Frequency range volt AC | 15Hertz – 20000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz |
Internal resistance volt AC | 9 1 |
5 | 9 1 |
9 1 |
5 |
Low-pass filter AC voltage (fc) | 1kiloHertz | 1kiloHertz | 1kiloHertz | 1kiloHertz | 1kiloHertz |
Voltage measuring range AC+DC | 0,00001Volt – 1000Volt | 1Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 1Volt – 600Volt |
Voltage measuring ranges AC+DC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, AC+DC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution volt AC+DC | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt |
Internal resistance volt AC+DC | 9 | 5 | 9 | 9 | 5 |
Frequency range volt AC+DC | 20kiloHertz | 100kiloHertz | 100kiloHertz | 100kiloHertz | 100kiloHertz |
Level measurement voltage types | AC | AC AC+DC |
AC | AC | AC AC+DC |
Measuring range voltage level for U ref = 0.775 V | -48Decibel – 63Decibel | -42Decibel – 57Decibel | -48Decibel – 63Decibel | -48Decibel – 63Decibel | -42Decibel – 57Decibel |
Lowest resolution voltage level | 0.01Decibel | 0.01Decibel | 0.01Decibel | 0.01Decibel | 0.01Decibel |
Current measurement | |||||
Current measurement types | DC AC AC+DC |
AC AC+DC DC |
DC AC AC+DC |
DC AC AC+DC |
AC AC+DC DC |
Current measurement range DC | 0,000001Ampere – 10Ampere | 0,000000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,000000001Ampere – 10Ampere |
Current measuring ranges DC | 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range, DC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution, DC current | 1 µA | 0.001 µA | 0.01 µA | 0.01 µA | 0.001 µA |
Current measurement range AC | 0,000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere |
Current measuring ranges AC | 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range, AC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution, AC current | 1 µA | 0.01 µA | 0.01 µA | 0.01 µA | 0.01 µA |
Frequency range alternating current | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz |
Current measurement range AC+DC | 0,000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere |
Current measuring ranges AC+DC | 60 mA 600 mA 6 A 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6 A 10:00 AM |
600µA 6 mA 60 mA 600 mA 6 A 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range AC + DC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution amps AC+DC | 0.001Milliampere | 0,00001Milliampere | 0,00001Milliampere | 0,00001Milliampere | 0,00001Milliampere |
Frequency range amps AC+DC | 10kiloHertz | 10kiloHertz | 10kiloHertz | 10kiloHertz | 10kiloHertz |
Current sensor with clipping | x | x | x | x | x |
Current measuring range with current sensors | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 3000Ampere | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 3000Ampere |
Current transformer with clipping | x | x | x | x | x |
Current measuring range with current transformers | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 3000Ampere | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 3000Ampere |
Clip factors | 01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
Resistance measurement | |||||
Milliohm measurement with 4 wire technique (Kelvin connection) | |||||
Resistance test/diode test | x | x | x | x | x |
Continuity test | x | x | x | x | x |
With conductivity measurement | |||||
Resistance measurement range | 0.01Ohm – 60000000Ohm | 0.001Ohm – 30000000Ohm | 0.01Ohm – 60000000Ohm | 0.01Ohm – 60000000Ohm | 0.001Ohm – 30000000Ohm |
Resistance measurement ranges | 600 6 k 60 k 600 k 6 M 60 m |
300 3 k 30 k 300 k 3 M 30 m |
600 6 k 60 k 600 k 6 M 60 m |
600 6 k 60 k 600 k 6 M 60 m |
300 3 k 30 k 300 k 3 M 30 m |
Max. resistance measuring range | 60Mega-Ohm | 30Mega-Ohm | 60Mega-Ohm | 60Mega-Ohm | 30Mega-Ohm |
Lowest resolution, resistance | 0.01 Ohm | 0.001 Ohm | 0.01 Ohm | 0.01 Ohm | 0.001 Ohm |
Lowest resolution, milliohm measurement | 10Milli-Ohm | 1Milli-Ohm | 10Milli-Ohm | 10Milli-Ohm | 1Milli-Ohm |
Nominal test voltage 10 V | |||||
Nominal test voltage 50 V | |||||
Nominal test voltage 100 V | |||||
Nominal test voltage 250 V | |||||
Nominal test voltage 500 V | |||||
Nominal test voltage 1000 V | |||||
Capacitance measurement | |||||
Capacitance measurement | x | x | x | x | x |
Capacitance measuring range | 0,00001Mikro-Farad – 600Mikro-Farad | 0,000001Mikro-Farad – 300Mikro-Farad | 0,00001Mikro-Farad – 600Mikro-Farad | 0,00001Mikro-Farad – 600Mikro-Farad | 0,000001Mikro-Farad – 3000Mikro-Farad |
Capacitance measurement ranges | 60 nF 600 nF 6 �F 60 �F 600µF |
3 nF 30 nF 300 nF 3 µF 30 µF 300 µF 3 mF |
60 nF 600 nF 6 �F 60 �F 600µF |
60 nF 600 nF 6 �F 60 �F 600µF |
3 nF 30 nF 300 nF 3 µF 30 µF 300 µF 3 mF |
Max. capacitance measuring range | 600Mikro-Farad | 3000Mikro-Farad | 600Mikro-Farad | 600Mikro-Farad | 3000Mikro-Farad |
Lowest resolution, capacitance | 0.00001 µF | Other | 0.00001 µF | 0.00001 µF | Other |
Cable length measurement | |||||
Cable symmetry testing for two wire connections a-b-E | |||||
Frequency measurement | |||||
Frequency measurement | x | x | x | x | x |
Measuring range for frequency | 0,00001kiloHertz – 300kiloHertz | 0,000001kiloHertz – 1000kiloHertz | 0,00001kiloHertz – 1000kiloHertz | 0,00001kiloHertz – 1000kiloHertz | 0,000001kiloHertz – 1000kiloHertz |
Max. frequency measuring range | 300kiloHertz | 1000kiloHertz | 1000kiloHertz | 1000kiloHertz | 1000kiloHertz |
Lowest resolution, frequency | 0.01 Hz | 0.001 Hz | 0.01 Hz | 0.01 Hz | 0.001 Hz |
Temperature measurement | |||||
Temperature measurement | x | x | x | x | x |
Temperature measurement TC | x | x | x | x | x |
Temperature measuring range TC | -250Degrees celsius – 1372Degrees celsius | -270Degrees celsius – 1372Degrees celsius | -250Degrees celsius – 1372Degrees celsius | -250Degrees celsius – 1372Degrees celsius | -270Degrees celsius – 1372Degrees celsius |
Temperature measurement RTD | x | x | x | x | x |
Temperature measuring range RTD | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius |
Max. temperature measuring range | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius |
Lowest resolution temperature | 0.1 °C | 0.1 °C | 0.1 °C | 0.1 °C | 0.1 °C |
Interface and memory | |||||
Interface | x | x | x | x | x |
Bluetooth interface | x | ||||
IR interface | x | x | x | x | x |
Measured value memory | x | x | x | x | |
Miscellaneous | |||||
Power supply unit socket | x | x | x | x | |
Memory capacity for measured values | 61000 | 61000 | 300000 |