Gossen METRAHIT PM TUNE High-end TRMS Multimeter

  • 26 multimeter functions
  • Resolution: ±60,000 digits, 4 6/7-place
  • Basic accuracy: ±0.05% (VDC)
  • Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, level dB, relative value ΔREL, frequency (Hz, MHz), duty cycle, resistance, diode testing, continuity test, capacitance, current
  • ACTRMS, current AC+DCTRMS, temperature with Pt 100/1000 sensors and type K thermocouples
  • Auto-ranging current measurement from 10 nA to 10 A (16 A) via a single connector jack and a single fuse
  • Clip function for TRMS current measurement with sensors and transformers
  • Additional filter function and voltage measurement with reduced input impedance for limiting interference, e.g. for measurements at frequency converters
  • Automatic and manual measuring range selection
  • Zero adjustment
  • Automatic storage of measured values: DATA / MIN / MAX
  • 2 MB data memory for 61,600 measured values for long-term measurements with data logger function
  • Infrared interface for communication with the PC
  • Large, light-blue illuminated display with extra-large characters (15 mm) and an analog bar graph for dynamic processes
  • Separate battery and fuse compartments
  • Power pack connector socket for operation without batteries
  • Patented automatic blocking sockets (ABS)
  • Measuring category: 600 V CAT IV, 1000 V CAT III
  • Rubber holster for protection against shocks and impacts

Description

The Metrahit PM TUNE is a high-end, professional digital multimeter from the Metrahit Professional Multimeter series by Gossen Metrawatt. It’s specifically designed for tuning and adjustment tasks in various electrical and electronic applications.

Key Features:

  • The increased refresh-rate of the LCD reacts directly and without time delay to changed adjustments, e.g. of a potentiometer
  • Universal use in all fields of electrical engineering!
  • TRMS measurement up to 100 kHz with digital display (60,000 digits) and analog scale
  • Measurement of voltage and current, DC, AC and AC/DC, dB, ΔREL, resistance, temperature, frequency, duty cycle, capacitance, continuity/diodes
  • Automatic measuring range selection and measured value storage
  • Safety for the user and the instrument in measuring categories CAT IV up to 600 V and CAT III up to 1000 V.
  • High Accuracy & Resolution: Offers exceptional measurement accuracy and high resolution for precise readings.
  • Fast Response Time: Features a fast response time, crucial for tuning and adjusting sensitive circuits.

Benefits:

  • Enhanced Tuning Accuracy: Enables precise adjustments and calibrations in various electronic and electrical systems.
  • Improved Efficiency: Fast response time and high accuracy streamline tuning and troubleshooting processes.
  • Increased Productivity: Enables faster and more efficient work in applications requiring precise measurements.
  • Enhanced Reliability: Robust construction ensures reliable performance in demanding environments.

Applications:

  • Precise tuning and adjustment of electronic circuits
  • Audio and video equipment servicing
  • Industrial automation and control systems
  • Research and development
  • Any application where high accuracy and fast response times are critical

The Metrahit PM TUNE is a specialized multimeter designed for professionals who require the highest levels of accuracy and performance in their measurements. Its fast response time, high resolution, and rugged construction make it an ideal tool for demanding tuning and adjustment tasks.

Additional information

Brand

Gossen Metrawatt

Characteristic Values

METRAHIT PM TECH METRAHIT PM PRIME BT METRAHIT PM XTRA METRAHIT PM TUNE METRAHIT PM PRIME
Item number M253A M248B M250A M250T M248A
Display
Indication Analogue/digital Digital Analogue/digital Analogue/digital Digital
Indication digits 60000 310000 60000 60000 310000
Multiple display x x
Measuring range selection Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic
Basic data
Type of measurement TRMS TRMS TRMS TRMS TRMS
True RMS measurement x x x x x
Basic accuracy 0.05Percentage 0.02Percentage 0.05Percentage 0.05Percentage 0.02Percentage
Measuring circuit category CAT IV CAT IV CAT IV CAT IV CAT IV
Max. voltage measuring circuit category 600Volt 300Volt 600Volt 600Volt 300Volt
Relative value measurement x x x x x
Min. value storage x x x x x
Max. value storage x x x x x
Peak value memory
Data hold x x x x x
Special functions
Explosion-tested version
Power and energy measurement
Harmonics analysis/power quality
Crest factor measurement
Rotational speed measuring
Duty cycle measurements x x x x
Pulse freqency measurement MHz @ 5V TTL x x x x
Inductance measurement
Interturn short-circuit high-voltage test
Automatic circuit breaker
Voltage measurement
Voltage measurement types DC
AC
AC Fil
AC+DC
DC
AC
AC Fil
AC+DC
AC+DC Fil
DC
AC
AC Fil
AC+DC
DC
AC
AC Fil
AC+DC
DC
AC
AC Fil
AC+DC
AC+DC Fil
With decibel measurement (dB) x x x x x
Voltage measuring range DC 0,00001Volt – 1000Volt 0,000001Volt – 600Volt 0,00001Volt – 1000Volt 0,00001Volt – 1000Volt 0,000001Volt – 600Volt
Voltage measuring ranges DC 600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
Max. voltage measuring range, DC 1000Volt 600Volt 1000Volt 1000Volt 600Volt
Lowest resolution, DC voltage 0.01 mV 0.001 mV 0.01 mV 0.01 mV 0.001 mV
Internal resistance volt DC 9 10 9 9 10
Voltage measuring range AC 0,00001Volt – 1000Volt 1Volt – 600Volt 0,00001Volt – 1000Volt 0,00001Volt – 1000Volt 1Volt – 600Volt
Voltage measuring ranges AC 600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
Max. voltage measuring range, AC 1000Volt 600Volt 1000Volt 1000Volt 600Volt
Lowest resolution, AC voltage 0.01 mV 0.01 mV 0.01 mV 0.01 mV 0.01 mV
Frequency range volt AC 15Hertz – 20000Hertz 15Hertz – 100000Hertz 15Hertz – 100000Hertz 15Hertz – 100000Hertz 15Hertz – 100000Hertz
Internal resistance volt AC 9
1
5 9
1
9
1
5
Low-pass filter AC voltage (fc) 1kiloHertz 1kiloHertz 1kiloHertz 1kiloHertz 1kiloHertz
Voltage measuring range AC+DC 0,00001Volt – 1000Volt 1Volt – 600Volt 0,00001Volt – 1000Volt 0,00001Volt – 1000Volt 1Volt – 600Volt
Voltage measuring ranges AC+DC 600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
300 mV
3 V
30 V
300 V
600 V
Max. voltage measuring range, AC+DC 1000Volt 600Volt 1000Volt 1000Volt 600Volt
Lowest resolution volt AC+DC 0.01Millivolt 0.01Millivolt 0.01Millivolt 0.01Millivolt 0.01Millivolt
Internal resistance volt AC+DC 9 5 9 9 5
Frequency range volt AC+DC 20kiloHertz 100kiloHertz 100kiloHertz 100kiloHertz 100kiloHertz
Level measurement voltage types AC AC
AC+DC
AC AC AC
AC+DC
Measuring range voltage level for U ref = 0.775 V -48Decibel – 63Decibel -42Decibel – 57Decibel -48Decibel – 63Decibel -48Decibel – 63Decibel -42Decibel – 57Decibel
Lowest resolution voltage level 0.01Decibel 0.01Decibel 0.01Decibel 0.01Decibel 0.01Decibel
Current measurement
Current measurement types DC
AC
AC+DC
AC
AC+DC
DC
DC
AC
AC+DC
DC
AC
AC+DC
AC
AC+DC
DC
Current measurement range DC 0,000001Ampere – 10Ampere 0,000000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,000000001Ampere – 10Ampere
Current measuring ranges DC 60 mA
600 mA
6:00 AM
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
600µA
6 mA
60 mA
600 mA
6:00 AM
10:00 AM
600µA
6 mA
60 mA
600 mA
6:00 AM
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
Max. current measuring range, DC 10Ampere 10Ampere 10Ampere 10Ampere 10Ampere
Lowest resolution, DC current 1 µA 0.001 µA 0.01 µA 0.01 µA 0.001 µA
Current measurement range AC 0,000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere
Current measuring ranges AC 60 mA
600 mA
6:00 AM
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
600µA
6 mA
60 mA
600 mA
6:00 AM
10:00 AM
600µA
6 mA
60 mA
600 mA
6:00 AM
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
Max. current measuring range, AC 10Ampere 10Ampere 10Ampere 10Ampere 10Ampere
Lowest resolution, AC current 1 µA 0.01 µA 0.01 µA 0.01 µA 0.01 µA
Frequency range alternating current 15Hertz – 10000Hertz 15Hertz – 10000Hertz 15Hertz – 10000Hertz 15Hertz – 10000Hertz 15Hertz – 10000Hertz
Current measurement range AC+DC 0,000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere 0,00000001Ampere – 10Ampere
Current measuring ranges AC+DC 60 mA
600 mA
6 A
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
600µA
6 mA
60 mA
600 mA
6 A
10:00 AM
600µA
6 mA
60 mA
600 mA
6 A
10:00 AM
0.3 mA
3 mA
30 mA
300 mA
3:00 AM
10:00 AM
Max. current measuring range AC + DC 10Ampere 10Ampere 10Ampere 10Ampere 10Ampere
Lowest resolution amps AC+DC 0.001Milliampere 0,00001Milliampere 0,00001Milliampere 0,00001Milliampere 0,00001Milliampere
Frequency range amps AC+DC 10kiloHertz 10kiloHertz 10kiloHertz 10kiloHertz 10kiloHertz
Current sensor with clipping x x x x x
Current measuring range with current sensors 0,00001Ampere – 6000Ampere 0,00001Ampere – 3000Ampere 0,00001Ampere – 6000Ampere 0,00001Ampere – 6000Ampere 0,00001Ampere – 3000Ampere
Current transformer with clipping x x x x x
Current measuring range with current transformers 0,000001Ampere – 6000Ampere 0,000001Ampere – 3000Ampere 0,000001Ampere – 6000Ampere 0,000001Ampere – 6000Ampere 0,000001Ampere – 3000Ampere
Clip factors 01:01
01:10
0,111111111
0,736111111
01:01
01:10
0,111111111
0,736111111
01:01
01:10
0,111111111
0,736111111
01:01
01:10
0,111111111
0,736111111
01:01
01:10
0,111111111
0,736111111
Resistance measurement
Milliohm measurement with 4 wire technique (Kelvin connection)
Resistance test/diode test x x x x x
Continuity test x x x x x
With conductivity measurement
Resistance measurement range 0.01Ohm – 60000000Ohm 0.001Ohm – 30000000Ohm 0.01Ohm – 60000000Ohm 0.01Ohm – 60000000Ohm 0.001Ohm – 30000000Ohm
Resistance measurement ranges 600
6 k
60 k
600 k
6 M
60 m
300
3 k
30 k
300 k
3 M
30 m
600
6 k
60 k
600 k
6 M
60 m
600
6 k
60 k
600 k
6 M
60 m
300
3 k
30 k
300 k
3 M
30 m
Max. resistance measuring range 60Mega-Ohm 30Mega-Ohm 60Mega-Ohm 60Mega-Ohm 30Mega-Ohm
Lowest resolution, resistance 0.01 Ohm 0.001 Ohm 0.01 Ohm 0.01 Ohm 0.001 Ohm
Lowest resolution, milliohm measurement 10Milli-Ohm 1Milli-Ohm 10Milli-Ohm 10Milli-Ohm 1Milli-Ohm
Nominal test voltage 10 V
Nominal test voltage 50 V
Nominal test voltage 100 V
Nominal test voltage 250 V
Nominal test voltage 500 V
Nominal test voltage 1000 V
Capacitance measurement
Capacitance measurement x x x x x
Capacitance measuring range 0,00001Mikro-Farad – 600Mikro-Farad 0,000001Mikro-Farad – 300Mikro-Farad 0,00001Mikro-Farad – 600Mikro-Farad 0,00001Mikro-Farad – 600Mikro-Farad 0,000001Mikro-Farad – 3000Mikro-Farad
Capacitance measurement ranges 60 nF
600 nF
6 �F
60 �F
600µF
3 nF
30 nF
300 nF
3 µF
30 µF
300 µF
3 mF
60 nF
600 nF
6 �F
60 �F
600µF
60 nF
600 nF
6 �F
60 �F
600µF
3 nF
30 nF
300 nF
3 µF
30 µF
300 µF
3 mF
Max. capacitance measuring range 600Mikro-Farad 3000Mikro-Farad 600Mikro-Farad 600Mikro-Farad 3000Mikro-Farad
Lowest resolution, capacitance 0.00001 µF Other 0.00001 µF 0.00001 µF Other
Cable length measurement
Cable symmetry testing for two wire connections a-b-E
Frequency measurement
Frequency measurement x x x x x
Measuring range for frequency 0,00001kiloHertz – 300kiloHertz 0,000001kiloHertz – 1000kiloHertz 0,00001kiloHertz – 1000kiloHertz 0,00001kiloHertz – 1000kiloHertz 0,000001kiloHertz – 1000kiloHertz
Max. frequency measuring range 300kiloHertz 1000kiloHertz 1000kiloHertz 1000kiloHertz 1000kiloHertz
Lowest resolution, frequency 0.01 Hz 0.001 Hz 0.01 Hz 0.01 Hz 0.001 Hz
Temperature measurement
Temperature measurement x x x x x
Temperature measurement TC x x x x x
Temperature measuring range TC -250Degrees celsius – 1372Degrees celsius -270Degrees celsius – 1372Degrees celsius -250Degrees celsius – 1372Degrees celsius -250Degrees celsius – 1372Degrees celsius -270Degrees celsius – 1372Degrees celsius
Temperature measurement RTD x x x x x
Temperature measuring range RTD -200Degrees celsius – 850Degrees celsius -200Degrees celsius – 850Degrees celsius -200Degrees celsius – 850Degrees celsius -200Degrees celsius – 850Degrees celsius -200Degrees celsius – 850Degrees celsius
Max. temperature measuring range 1372Degrees celsius 1372Degrees celsius 1372Degrees celsius 1372Degrees celsius 1372Degrees celsius
Lowest resolution temperature 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C
Interface and memory
Interface x x x x x
Bluetooth interface x
IR interface x x x x x
Measured value memory x x x x
Miscellaneous
Power supply unit socket x x x x
Memory capacity for measured values 61000 61000 300000

 