Gossen METRAHIT PM TECH High-end TRMS Multimeter
- Universal use in all fields of electrical engineering!
- TRMS measurement up to 20 kHz with digital display (60,000 digits) and analog scale
- Measurement of voltage and current, DC, AC and AC+DC, dB, resistance, capacitance, temperature, frequency, continuity/diodes
- Clip function for current measurement with transformers and sensors
- Automatic measuring range selection and measured value storage
- Safety for the user and the instrument in measuring categories CAT IV up to 600 V and CAT III up to 1000 V.
- Description
- Additional information
- Specifications
Description
The Metrahit PM TECH is a high-performance digital multimeter from the Metrahit Professional Multimeter series by Gossen Metrawatt. It’s designed for a wide range of demanding electrical and electronic applications, offering a balance of accuracy, versatility, and user-friendliness.
Key Features:
- Universal use in all fields of electrical engineering!
- TRMS measurement up to 20 kHz with digital display (60,000 digits) and analog scale
- Measurement of voltage and current, DC, AC and AC+DC, dB, resistance, capacitance, temperature, frequency, continuity/diodes
- Clip function for current measurement with transformers and sensors
- Automatic measuring range selection and measured value storage
- Safety for the user and the instrument in measuring categories CAT IV up to 600 V and CAT III up to 1000 V.
- High Accuracy: Provides accurate measurements for various electrical parameters, including voltage, current, resistance, capacitance, frequency, and more.
- True RMS Measurements: Ensures accurate readings for both DC and AC signals, including non-sinusoidal waveforms.
- User-Friendly Interface: Features a clear display and intuitive controls for easy operation.
Benefits:
- Reliable Measurements: Delivers accurate and reliable results for a wide range of electrical measurements.
- Versatility: Suitable for a broad range of applications in electrical installation, maintenance, and troubleshooting.
- Durability: Built to withstand the rigors of daily use and provide long-lasting performance.
- Cost-Effective: Offers a good balance of performance and affordability for professional use.
The Metrahit PM TECH is a versatile and reliable digital multimeter that provides accurate measurements and essential features for a wide range of professional applications. It’s a solid choice for electricians, technicians, and anyone who needs a dependable and user-friendly multimeter for their daily work.
Additional information
Brand | Gossen Metrawatt |
---|
Characteristic Values
METRAHIT PM TECH | METRAHIT PM PRIME BT | METRAHIT PM XTRA | METRAHIT PM TUNE | METRAHIT PM PRIME | |
Item number | M253A | M248B | M250A | M250T | M248A |
Display | |||||
Indication | Analogue/digital | Digital | Analogue/digital | Analogue/digital | Digital |
Indication digits | 60000 | 310000 | 60000 | 60000 | 310000 |
Multiple display | x | x | |||
Measuring range selection | Manual/automatic | Manual/automatic | Manual/automatic | Manual/automatic | Manual/automatic |
Basic data | |||||
Type of measurement | TRMS | TRMS | TRMS | TRMS | TRMS |
True RMS measurement | x | x | x | x | x |
Basic accuracy | 0.05Percentage | 0.02Percentage | 0.05Percentage | 0.05Percentage | 0.02Percentage |
Measuring circuit category | CAT IV | CAT IV | CAT IV | CAT IV | CAT IV |
Max. voltage measuring circuit category | 600Volt | 300Volt | 600Volt | 600Volt | 300Volt |
Relative value measurement | x | x | x | x | x |
Min. value storage | x | x | x | x | x |
Max. value storage | x | x | x | x | x |
Peak value memory | |||||
Data hold | x | x | x | x | x |
Special functions | |||||
Explosion-tested version | |||||
Power and energy measurement | |||||
Harmonics analysis/power quality | |||||
Crest factor measurement | |||||
Rotational speed measuring | |||||
Duty cycle measurements | x | x | x | x | |
Pulse freqency measurement MHz @ 5V TTL | x | x | x | x | |
Inductance measurement | |||||
Interturn short-circuit high-voltage test | |||||
Automatic circuit breaker | |||||
Voltage measurement | |||||
Voltage measurement types | DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC AC+DC Fil |
DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC |
DC AC AC Fil AC+DC AC+DC Fil |
With decibel measurement (dB) | x | x | x | x | x |
Voltage measuring range DC | 0,00001Volt – 1000Volt | 0,000001Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 0,000001Volt – 600Volt |
Voltage measuring ranges DC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, DC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution, DC voltage | 0.01 mV | 0.001 mV | 0.01 mV | 0.01 mV | 0.001 mV |
Internal resistance volt DC | 9 | 10 | 9 | 9 | 10 |
Voltage measuring range AC | 0,00001Volt – 1000Volt | 1Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 1Volt – 600Volt |
Voltage measuring ranges AC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, AC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution, AC voltage | 0.01 mV | 0.01 mV | 0.01 mV | 0.01 mV | 0.01 mV |
Frequency range volt AC | 15Hertz – 20000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz | 15Hertz – 100000Hertz |
Internal resistance volt AC | 9 1 |
5 | 9 1 |
9 1 |
5 |
Low-pass filter AC voltage (fc) | 1kiloHertz | 1kiloHertz | 1kiloHertz | 1kiloHertz | 1kiloHertz |
Voltage measuring range AC+DC | 0,00001Volt – 1000Volt | 1Volt – 600Volt | 0,00001Volt – 1000Volt | 0,00001Volt – 1000Volt | 1Volt – 600Volt |
Voltage measuring ranges AC+DC | 600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
600 mV 6 V 60 V 600 V 1000 V |
600 mV 6 V 60 V 600 V 1000 V |
300 mV 3 V 30 V 300 V 600 V |
Max. voltage measuring range, AC+DC | 1000Volt | 600Volt | 1000Volt | 1000Volt | 600Volt |
Lowest resolution volt AC+DC | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt | 0.01Millivolt |
Internal resistance volt AC+DC | 9 | 5 | 9 | 9 | 5 |
Frequency range volt AC+DC | 20kiloHertz | 100kiloHertz | 100kiloHertz | 100kiloHertz | 100kiloHertz |
Level measurement voltage types | AC | AC AC+DC |
AC | AC | AC AC+DC |
Measuring range voltage level for U ref = 0.775 V | -48Decibel – 63Decibel | -42Decibel – 57Decibel | -48Decibel – 63Decibel | -48Decibel – 63Decibel | -42Decibel – 57Decibel |
Lowest resolution voltage level | 0.01Decibel | 0.01Decibel | 0.01Decibel | 0.01Decibel | 0.01Decibel |
Current measurement | |||||
Current measurement types | DC AC AC+DC |
AC AC+DC DC |
DC AC AC+DC |
DC AC AC+DC |
AC AC+DC DC |
Current measurement range DC | 0,000001Ampere – 10Ampere | 0,000000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,000000001Ampere – 10Ampere |
Current measuring ranges DC | 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range, DC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution, DC current | 1 µA | 0.001 µA | 0.01 µA | 0.01 µA | 0.001 µA |
Current measurement range AC | 0,000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere |
Current measuring ranges AC | 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6:00 AM 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range, AC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution, AC current | 1 µA | 0.01 µA | 0.01 µA | 0.01 µA | 0.01 µA |
Frequency range alternating current | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz | 15Hertz – 10000Hertz |
Current measurement range AC+DC | 0,000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere | 0,00000001Ampere – 10Ampere |
Current measuring ranges AC+DC | 60 mA 600 mA 6 A 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
600µA 6 mA 60 mA 600 mA 6 A 10:00 AM |
600µA 6 mA 60 mA 600 mA 6 A 10:00 AM |
0.3 mA 3 mA 30 mA 300 mA 3:00 AM 10:00 AM |
Max. current measuring range AC + DC | 10Ampere | 10Ampere | 10Ampere | 10Ampere | 10Ampere |
Lowest resolution amps AC+DC | 0.001Milliampere | 0,00001Milliampere | 0,00001Milliampere | 0,00001Milliampere | 0,00001Milliampere |
Frequency range amps AC+DC | 10kiloHertz | 10kiloHertz | 10kiloHertz | 10kiloHertz | 10kiloHertz |
Current sensor with clipping | x | x | x | x | x |
Current measuring range with current sensors | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 3000Ampere | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 6000Ampere | 0,00001Ampere – 3000Ampere |
Current transformer with clipping | x | x | x | x | x |
Current measuring range with current transformers | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 3000Ampere | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 6000Ampere | 0,000001Ampere – 3000Ampere |
Clip factors | 01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
01:01 01:10 0,111111111 0,736111111 |
Resistance measurement | |||||
Milliohm measurement with 4 wire technique (Kelvin connection) | |||||
Resistance test/diode test | x | x | x | x | x |
Continuity test | x | x | x | x | x |
With conductivity measurement | |||||
Resistance measurement range | 0.01Ohm – 60000000Ohm | 0.001Ohm – 30000000Ohm | 0.01Ohm – 60000000Ohm | 0.01Ohm – 60000000Ohm | 0.001Ohm – 30000000Ohm |
Resistance measurement ranges | 600 6 k 60 k 600 k 6 M 60 m |
300 3 k 30 k 300 k 3 M 30 m |
600 6 k 60 k 600 k 6 M 60 m |
600 6 k 60 k 600 k 6 M 60 m |
300 3 k 30 k 300 k 3 M 30 m |
Max. resistance measuring range | 60Mega-Ohm | 30Mega-Ohm | 60Mega-Ohm | 60Mega-Ohm | 30Mega-Ohm |
Lowest resolution, resistance | 0.01 Ohm | 0.001 Ohm | 0.01 Ohm | 0.01 Ohm | 0.001 Ohm |
Lowest resolution, milliohm measurement | 10Milli-Ohm | 1Milli-Ohm | 10Milli-Ohm | 10Milli-Ohm | 1Milli-Ohm |
Nominal test voltage 10 V | |||||
Nominal test voltage 50 V | |||||
Nominal test voltage 100 V | |||||
Nominal test voltage 250 V | |||||
Nominal test voltage 500 V | |||||
Nominal test voltage 1000 V | |||||
Capacitance measurement | |||||
Capacitance measurement | x | x | x | x | x |
Capacitance measuring range | 0,00001Mikro-Farad – 600Mikro-Farad | 0,000001Mikro-Farad – 300Mikro-Farad | 0,00001Mikro-Farad – 600Mikro-Farad | 0,00001Mikro-Farad – 600Mikro-Farad | 0,000001Mikro-Farad – 3000Mikro-Farad |
Capacitance measurement ranges | 60 nF 600 nF 6 �F 60 �F 600µF |
3 nF 30 nF 300 nF 3 µF 30 µF 300 µF 3 mF |
60 nF 600 nF 6 �F 60 �F 600µF |
60 nF 600 nF 6 �F 60 �F 600µF |
3 nF 30 nF 300 nF 3 µF 30 µF 300 µF 3 mF |
Max. capacitance measuring range | 600Mikro-Farad | 3000Mikro-Farad | 600Mikro-Farad | 600Mikro-Farad | 3000Mikro-Farad |
Lowest resolution, capacitance | 0.00001 µF | Other | 0.00001 µF | 0.00001 µF | Other |
Cable length measurement | |||||
Cable symmetry testing for two wire connections a-b-E | |||||
Frequency measurement | |||||
Frequency measurement | x | x | x | x | x |
Measuring range for frequency | 0,00001kiloHertz – 300kiloHertz | 0,000001kiloHertz – 1000kiloHertz | 0,00001kiloHertz – 1000kiloHertz | 0,00001kiloHertz – 1000kiloHertz | 0,000001kiloHertz – 1000kiloHertz |
Max. frequency measuring range | 300kiloHertz | 1000kiloHertz | 1000kiloHertz | 1000kiloHertz | 1000kiloHertz |
Lowest resolution, frequency | 0.01 Hz | 0.001 Hz | 0.01 Hz | 0.01 Hz | 0.001 Hz |
Temperature measurement | |||||
Temperature measurement | x | x | x | x | x |
Temperature measurement TC | x | x | x | x | x |
Temperature measuring range TC | -250Degrees celsius – 1372Degrees celsius | -270Degrees celsius – 1372Degrees celsius | -250Degrees celsius – 1372Degrees celsius | -250Degrees celsius – 1372Degrees celsius | -270Degrees celsius – 1372Degrees celsius |
Temperature measurement RTD | x | x | x | x | x |
Temperature measuring range RTD | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius | -200Degrees celsius – 850Degrees celsius |
Max. temperature measuring range | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius | 1372Degrees celsius |
Lowest resolution temperature | 0.1 °C | 0.1 °C | 0.1 °C | 0.1 °C | 0.1 °C |
Interface and memory | |||||
Interface | x | x | x | x | x |
Bluetooth interface | x | ||||
IR interface | x | x | x | x | x |
Measured value memory | x | x | x | x | |
Miscellaneous | |||||
Power supply unit socket | x | x | x | x | |
Memory capacity for measured values | 61000 | 61000 | 300000 |