Fluke 792A AC/DC Transfer Standard
- Ultra-high accuracy AC/DC Thermal Transfer Standard with uncertainties as low as ±10 ppm (±5 ppm from NIST).
- 2 mV to 1000V voltage range, 10 Hz to 1 MHz frequency range
- Features a Fluke Calibration solid-state RMS sensor for temperature stability and fast settling time; measurements made in as short as 30 seconds.
- The 792A consists of four units including a Transfer Unit, a Power Pack unit, a 1000V Range Resistor and a Transfer Switch, and is shipped from the factory traceable to national standards with a table of correction factors and uncertainties.
- Description
- Additional information
- Specifications
Description
The Fluke 792A is an ultra-high accuracy AC/DC Thermal Transfer Standard.
Key Features:
- Ultra-high accuracy AC/DC Thermal Transfer Standard with uncertainties as low as ±10 ppm (±5 ppm from NIST).
- 2 mV to 1000V voltage range, 10 Hz to 1 MHz frequency range
- Features a Fluke Calibration solid-state RMS sensor for temperature stability and fast settling time; measurements made in as short as 30 seconds.
- The 792A consists of four units including a Transfer Unit, a Power Pack unit, a 1000V Range Resistor and a Transfer Switch, and is shipped from the factory traceable to national standards with a table of correction factors and uncertainties.
- Exceptional Accuracy: Achieves uncertainties as low as ±10 ppm (±5 ppm from NIST).
- Solid-State Thermal RMS Sensor: Employs a patented Fluke Solid-State Thermal RMS sensor for temperature stability and fast settling time.
- Wide Frequency Range: Covers a broad frequency range from 10 Hz to 1 MHz.
- High Voltage Range: Measures voltages from 2 mV to 1000 V.
- Fast Measurements: Enables measurements in as short as 30 seconds.
Applications:
- Calibrating AC voltmeters
- Calibrating oscilloscopes
- Calibrating power analyzers
- Research and development in metrology
In essence, the Fluke 792A is a cornerstone for establishing and maintaining the accuracy of AC voltage measurements in demanding metrology laboratories.
Additional information
Brand | Fluke Calibration |
---|
Specifications: 792A AC/DC Transfer Standard
General Specifications | |
AC-DC Difference | Range: 2 mV to 1000V 10 Hz to 1 MHz Best 1 Year Specification: ± 10ppm |
Temperature Stabilization | Allow 12 hours stabilization time in the environment of use |
Warm up Time | 15 minutes with power on, after stabilization time |
Temperature Performance | Operating: 11°C to 35°C; Calibration: 18°C to 28°C; Storage: -40°C to 50°C |
Relative Humidity | Operating: < 75% to 30°C, < 70% to 35°C; Storage: < 95%, non-condensing |
Altitude | Operating: to 3,050 m (10,000 ft); Non-operating: to 12,200 m (40,000 ft) |
Input Low Isolation | 20V to chassis |
Guard Isolation | 10V to input LO or chassis |
EMI/RFI | Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B; VDE 0875, Class K |
Line Power | MIL-STD-28800D, paragraph 3.13.3 |
Calibration Documentation | Report of calibration with data included; 17025 accredited report or Z520.1 report optional |
Size | Transfer Unit: 17.8 cm H x 21.6 cm W x 30.5 cm D (7 in H x 8.5 in W x 12 in D) Power Pack: 17.8 cm H x 21.6 cm W x 30.5 cm D (7 in H x 8.5 in W x 12 in D) 1000V Range Resistor: 7.6 cm H x 8.9 cm W x 14.0 cm D (3 in H x 3.5 in W x 5.5 in D) Transfer Switch: 7.6 cm H x 8.9 cm W x 14.0 cm D (3 in H x 3.5 in W x 5.5 in D) |
Weight | Transfer Unit: 8.4 kg (18.5 lb) Power Pack: 8.9 kg (19.5 lb) 1000V Range Resistor: 1.6 kg (3.5 lb) Transfer Switch: 1.6 kg (3.5 lb) |