Fluke 792A AC/DC Transfer Standard

  • Ultra-high accuracy AC/DC Thermal Transfer Standard with uncertainties as low as ±10 ppm (±5 ppm from NIST).
  • 2 mV to 1000V voltage range, 10 Hz to 1 MHz frequency range
  • Features a Fluke Calibration solid-state RMS sensor for temperature stability and fast settling time; measurements made in as short as 30 seconds.
  • The 792A consists of four units including a Transfer Unit, a Power Pack unit, a 1000V Range Resistor and a Transfer Switch, and is shipped from the factory traceable to national standards with a table of correction factors and uncertainties.

Description

The Fluke 792A is an ultra-high accuracy AC/DC Thermal Transfer Standard.

Key Features:

  • Ultra-high accuracy AC/DC Thermal Transfer Standard with uncertainties as low as ±10 ppm (±5 ppm from NIST).
  • 2 mV to 1000V voltage range, 10 Hz to 1 MHz frequency range
  • Features a Fluke Calibration solid-state RMS sensor for temperature stability and fast settling time; measurements made in as short as 30 seconds.
  • The 792A consists of four units including a Transfer Unit, a Power Pack unit, a 1000V Range Resistor and a Transfer Switch, and is shipped from the factory traceable to national standards with a table of correction factors and uncertainties.
  • Exceptional Accuracy: Achieves uncertainties as low as ±10 ppm (±5 ppm from NIST).
  • Solid-State Thermal RMS Sensor: Employs a patented Fluke Solid-State Thermal RMS sensor for temperature stability and fast settling time.
  • Wide Frequency Range: Covers a broad frequency range from 10 Hz to 1 MHz.
  • High Voltage Range: Measures voltages from 2 mV to 1000 V.
  • Fast Measurements: Enables measurements in as short as 30 seconds.

Applications:

  • Calibrating AC voltmeters
  • Calibrating oscilloscopes
  • Calibrating power analyzers
  • Research and development in metrology

In essence, the Fluke 792A is a cornerstone for establishing and maintaining the accuracy of AC voltage measurements in demanding metrology laboratories.

 

Additional information

Brand

Fluke Calibration

Specifications: 792A AC/DC Transfer Standard

General Specifications
AC-DC Difference Range: 2 mV to 1000V
10 Hz to 1 MHz
Best 1 Year Specification: ± 10ppm
Temperature Stabilization Allow 12 hours stabilization time in the environment of use
Warm up Time 15 minutes with power on, after stabilization time
Temperature Performance Operating: 11°C to 35°C;
Calibration: 18°C to 28°C;
Storage: -40°C to 50°C
Relative Humidity Operating: < 75% to 30°C, < 70% to 35°C;
Storage: < 95%, non-condensing
Altitude Operating: to 3,050 m (10,000 ft);
Non-operating: to 12,200 m (40,000 ft)
Input Low Isolation  20V to chassis
Guard Isolation 10V to input LO or chassis
EMI/RFI Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B; VDE 0875, Class K
Line Power MIL-STD-28800D, paragraph 3.13.3
Calibration Documentation Report of calibration with data included; 17025 accredited report or Z520.1 report optional
Size Transfer Unit: 17.8 cm H x 21.6 cm W x 30.5 cm D (7 in H x 8.5 in W x 12 in D)
Power Pack: 17.8 cm H x 21.6 cm W x 30.5 cm D (7 in H x 8.5 in W x 12 in D)
1000V Range Resistor: 7.6 cm H x 8.9 cm W x 14.0 cm D (3 in H x 3.5 in W x 5.5 in D)
Transfer Switch: 7.6 cm H x 8.9 cm W x 14.0 cm D (3 in H x 3.5 in W x 5.5 in D)
Weight Transfer Unit: 8.4 kg (18.5 lb)
Power Pack: 8.9 kg (19.5 lb)
1000V Range Resistor: 1.6 kg (3.5 lb)
Transfer Switch: 1.6 kg (3.5 lb)

 