Fluke 5080A High Compliance Multi-Product Calibrator
- Calibration solutions for both analog and digital workloads with high compliance and protection circuitry.
- Calibrate analog meters, 3.5 and 4.5 digits DMMs, panel meters, watt meters, clamp meters, oscilloscopes up to 200 MHz, and more.
- Equipped with versatile software applications for paperless results recording.
- Built-in protection circuitry to safeguard against damaging input voltages.
- Description
- Additional information
- Specifications
Description
The Fluke 5080A is a high-compliance multi-product calibrator designed for calibrating a wide range of electrical instruments, particularly those with higher current and voltage requirements.
Key Features:
- Calibration solutions for both analog and digital workloads with high compliance and protection circuitry.
- Calibrate analog meters, 3.5 and 4.5 digits DMMs, panel meters, watt meters, clamp meters, oscilloscopes up to 200 MHz, and more.
- Equipped with versatile software applications for paperless results recording.
- Built-in protection circuitry to safeguard against damaging input voltages.
- High Voltage and Current Compliance: Offers high voltage and current output capabilities, enabling calibration of instruments that demand significant drive.
- Versatile Functionality: Capable of generating various electrical signals, including AC/DC voltage, AC/DC current, and resistance.
- Multi-Product Calibration: Designed to calibrate a wide range of instruments, including:
- Analog meters
- Panel meters
- Digital multimeters (DMMs)
- Wattmeters
- Clamp meters
- Oscilloscopes (with optional accessories)
- User-Friendly Interface: Features an intuitive interface for easy operation and navigation.
- Built-in Protection: Includes built-in protection circuitry to safeguard the calibrator and the devices under test.
Applications:
- Calibrating a wide range of electrical instruments in various industries, including:
- Manufacturing
- Research and development
- Aerospace
- Defense
In essence, the Fluke 5080A is a versatile and powerful calibration tool that simplifies the process of calibrating instruments with higher current and voltage requirements, ensuring accurate and reliable measurements.
Additional information
| Brand | Fluke Calibration |
|---|
Specifications: 5080A High Compliance Multi-Product Calibrator
| Technical Specifications | |
| Voltage DC | Range: 0 to ±1020V Best 1 Year Specification: ±0.025% of setting |
| Current DC | Range: 0 to ±20.5A Best 1 Year Specification: ±0.025% of setting |
| Resistance | Range: 0 to 190 MO, 19 values in x1 and x1.9 Best 1 Year Specification: ±0.025% of setting |
| Voltage AC | Range: 1 mV to 1020V 45Hz to 1 kHz, Sine Best 1 Year Specification: ±0.25% of setting |
| Current AC | Range:29 mA to 20.5A 45 Hz to 1 kHz, Sine Best 1 Year Specification: ±0.25% of setting |
| DC Power | Range:10.9 mW to 20.5 kW Best 1 Year Specification: ±0.125% of setting |
| AC Power | Range: 10.9 mW to 20.5 kW 45-65 Hz, PF=1 Best 1 Year Specification: ±0.36% of setting |
| Phase | Range: 0 to ± 179.99° 45 Hz to 1 kHz Best 1 Year Specification: ±0.25° of setting |
| Frequency | Range: 45 Hz to 1 kHz Best 1 Year Specification: ±50 ppm of setting |
| General Specifications | |
| Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
| Settling Time | Less than 5 seconds for all functions and ranges except as noted |
| Standard Interfaces | RS-232 and Ethernet |
| Temperature Performance | Operating: 0°C to 50°C Calibration (tcal):15°C to 35°C Storage:-20°C to +70°C |
| Temperature Coefficient | Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C. |
| Relative Humidity | Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C Storage:<925%, non-condensing |
| Altitude | Operating: 2,000m (6,500 ft) maximum Non-operating: 12,200m (40,000 ft) maximum |
| Safety | Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004 |
| Analog Low Isolation | 20V |
| EMC | Meets EN613261:2006. |
| Line Power | Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: + 25% about line voltage setting |
| Power Consumption | 600 VA |
| Calibration Documentation | Report of calibration with data included; 17025 accredited report optional |
| Dimensions | Height:19.3 cm (7.6 in) Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles Depth:53.8 cm (21.2 in) |
| Weight (without options) | 22 kg (48 lbs.) |
| Absolute Uncertainty Definition | The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated. |
| Specification Confidence Interval | 99% |
Related Products
- Supply DC current up to 100 amps and AC current up to 120 amps, with accuracies to 140 ppm.
- Generate 3,000 or 6,000 amps using accessory coils, up to 360 amps with three 52120As are connected in parallel.
- Frequency: DC to 10 kHz, a burden voltage (compliance): 4.5 V @ 120 A, inductive drive capability: 1 mH load.
- Allows for parallel operation with 2 or 3 amplifiers up to 360 A in a single phase, or up to 10 amplifiers and 1200 A in standalone mode.
- Calibrates a wide range of equipment from Hipot testers to portable appliance testers.
- Many functions in one instrument. Variable high voltage resistance outputs, Active Loop Compensation, a 600 V source, 4-wire low resistance sources, and optional high voltage load resistors.
- Simulate RCD, display Ripple coefficient and THD measurements, with multiple models available.
- Automate with MET/CAL software for improved consistency.
- Intuitive calibration experience with 17.8 centimeter color touch screen
- Better match your existing digital multimeter workload with optimized ranging
- Easily calibrate meters that measure AC/DC voltage, resistance and capacitance
- 30 A continuous current output extends AC/DC measurement ranges
- Broadens AC voltage output capability, increasing frequency limits to 100 kHz at 750 V and 30 kHz at 1100 V.
- Provides enhanced load limits of up to 70 mA for frequencies above 5 kHz and up to 50 mA for frequencies less than 5 kHz.
- Boosts capacitive load limits to 1000 pF.
- Works in tandem with the 5700A Series Multifunction Calibrators, with control facilitated through an interface cable
- Calibrate up to long-scale 8.5 digit digital multimeters and RF voltmeters with wideband option.
- Improved AC voltage, AC current, and resistance specifications for increased test uncertainty ratios (TURs).
- 6.5-inch VGA touchscreen, a full-color interface, and Visual Connection Management™ output terminals
- Full Met/CAL® compatibility with 5700A and 5720A procedures
- High Accuracy: Both models offer exceptional accuracy for voltage, current, and power measurements, ensuring precise calibration results.
- Wide Signal Generation:
- Can be configured for various applications, such as power meter, energy meter, and power analyzer calibration.
- Versatile, precise benchtop tool to source and measure DC voltage, current, resistance, RTDs and thermocouples.
- Comprehensive calibration solution for temperature and pressure process instrumentation like RTD and thermocouple readouts, pressure gauges, temperature transmitters, digital process simulators, data loggers, and multimeters.
- Enhanced calibration range: 24 V DC transmitter loop power supply and measures 4-20 mA loop current.
- Fully automated, upgradeable calibration tool, offering hands-free, accurate oscilloscope calibration at a cost-effective price and performance level.
- Ultimate leveled sine performance up to 6.0 GHz with pulse edges of only 70 ps.
- Active Head Technology™ enables adjustable output amplitude between 4.44 mV and 3.1V.
- Controlled waveshape filtering ensures accurate energy distribution regardless of chosen amplitude.
- Simultaneous output on 5 channels,no need for lead changing and complex signal multiplexers or impedance matching network.
- Unparalleled Accuracy: Delivers exceptional accuracy and precision, ensuring reliable calibration results for even the most demanding high-speed oscilloscopes.
- Multi-Channel Calibration: Unique capability to calibrate multiple oscilloscope channels simultaneously, significantly increasing efficiency and reducing test time.
- Active Head Technology: Innovative technology that delivers signals directly at the oscilloscope’s input, minimizing signal degradation and ensuring accurate measurements.
- Full Automation: Automates the entire calibration process, reducing manual intervention and minimizing the risk of human error.