Fluke 5560A, 5550A and 5540A Multi-Product Calibrators

  • Intuitive calibration experience with 17.8 centimeter color touch screen
  • Better match your existing digital multimeter workload with optimized ranging
  • Easily calibrate meters that measure AC/DC voltage, resistance and capacitance
  • 30 A continuous current output extends AC/DC measurement ranges

Description

The Fluke 5560A, 5550A, and 5540A are high-performance multi-product calibrators designed to ensure the accuracy and reliability of a wide range of electrical test equipment. These advanced calibrators offer exceptional accuracy and precision, enabling them to calibrate a broad spectrum of electrical parameters, including AC/DC voltage, current, resistance, frequency, and more

Ensure the accuracy and reliability of your critical measurement equipment with the Fluke 5560A, 5550A, and 5540A series of high-performance multi-product calibrators. These cutting-edge instruments deliver exceptional accuracy and precision, covering a wide range of electrical parameters, including voltage, current, resistance, frequency, and more.

Key Benefits:

  • Unmatched Accuracy: Achieve the highest level of measurement accuracy and reliability.
  • Versatility: Calibrate a wide range of electrical test equipment with ease.
  • Enhanced Efficiency: Streamlined workflows and intuitive interfaces minimize downtime and maximize productivity.
  • Automation Ready: Integrate seamlessly with automated calibration systems for increased throughput.

Ideal for:

  • Calibration laboratories
  • Field service technicians
  • Research and development
  • Educational institutions

Experience the difference with Fluke 5560A, 5550A, and 5540A. Contact us today for a demonstration or to learn more.

Additional information

Brand

Fluke Calibration

Specifications: Fluke 5560A, 5550A and 5540A Multi-Product Calibrators

Function Range
Direct volts 0 V to ± 1020 V
Direct current 0 to ± 30.2 A
Alternating volts 1 mV to 1020 V
3 Hz to 500 kHz
Alternating current 10 μA to 30.2 A
3 Hz to 30 kHz
Volt/hertz 1000 V at 10 kHz/330 V at 100 kHz
Waveforms Sine wave, triangle wave and
truncated sine wave
Resistance variable 0 Ω to 1200 MΩ
Capacitance variable 200 pF to 120 Mf
Inductance variable 12 uH to 12 H
Power (dual output – phantom loads) 30.9 KW
Oscilloscope bandwidth 5560A: 2.1 GHz, 1.1 GHz, or 600 MHz
5550A: 1.1 GHz or 600 MHz
5540A: 600 MHz
Phase lock Yes
Phase control 0.01°
Frequency uncertainty <2.5 ppm
Temperature standard <=”” td=”” style=”box-sizing: inherit;”>
Resistance temperature detectors
(RTDs) output
Pt100 385, Pt100 395, Pt100 3916, Pt200 385,
Pt500 385, Pt1000 385, Ni120, Cu10
Compensation: off, 2-wire, 4-wire
External frequency reference 10 MHz Yes
Thermocouples (source and measure)
External or internal CJR
B,C,E,J,K,L,N,R,S,U, BP and XK
10 μV/°C
Scope calibrator SC600 – with levelled sine up to 600 MHz
SC1100 – with levelled sine up to 1100 MHz
SC2100 – with levelled sine up to 2100 MHz
Interfaces / Remote commands USB 2.0, Etherne Telnet, RS-232 and GPIB
52120A Amplifier current capability Current capability up to 120 A
Current capability up to 360 A with three
52120As (parallel)

 