Fluke 283 FC CAT III 1500V Digital Multimeter
- Safety Rating: CAT III 1500 V/CAT IV 1000 V, ensuring safe operation in high-voltage environments.
- True-RMS Measurement: Provides accurate readings for both sinusoidal and non-sinusoidal waveforms.
- Wireless Connectivity: Compatible with Fluke Connectâ„¢ for remote monitoring and data logging.
- Multimeter Readiness Self-Check: Verifies meter functionality before each use.
- Visual and Audio Polarity Indicators: Helps prevent accidental wiring errors.
- User-Defined Limit Gauge: Enables quick go/no-go decisions.
- High Accuracy Voltage Measurement: For precise troubleshooting.
- Current Measurement up to 60 A AC/DC: Safely troubleshoot individual strings of modules.
- Logging and Saving Features: Time- and date-stamped measurements for accurate recordkeeping.
- Customizable Logging: Flexible logging durations and intervals.
- Compatible with a283 FC Wireless Current Clamp: For remote current measurements.
- Description
- Additional information
- Specifications
Description
The Fluke 283 FC is a high-performance digital multimeter designed for professionals working in high-voltage DC environments. It offers a combination of safety, accuracy, and advanced features to ensure reliable measurements in demanding applications.
Key Features:
- Safety Rating: CAT III 1500 V/CAT IV 1000 V, ensuring safe operation in high-voltage environments.
- True-RMS Measurement: Provides accurate readings for both sinusoidal and non-sinusoidal waveforms.
- Wireless Connectivity: Compatible with Fluke Connectâ„¢ for remote monitoring and data logging.
- Multimeter Readiness Self-Check: Verifies meter functionality before each use.
- Visual and Audio Polarity Indicators: Helps prevent accidental wiring errors.
- User-Defined Limit Gauge: Enables quick go/no-go decisions.
- High Accuracy Voltage Measurement: For precise troubleshooting.
- Current Measurement up to 60 A AC/DC: Safely troubleshoot individual strings of modules.
- Logging and Saving Features: Time- and date-stamped measurements for accurate recordkeeping.
- Customizable Logging: Flexible logging durations and intervals.
- Compatible with a283 FC Wireless Current Clamp: For remote current measurements.
Applications:
- Utility-scale solar PV arrays
- Wind power systems
- Electric railways
- Data centers
Overall, the Fluke 283 FC is a powerful and versatile multimeter that provides the necessary tools for efficient and safe troubleshooting in high-voltage DC environments.
Additional information
Brand | Fluke |
---|
Specifications: Fluke 283 FC CAT III 1500V Digital Multimeter
Function | Range | Resolution | Accuracy |
AC volts[1] | 6.000 V | 0.001 V | 1.0 % + 3 (45 Hz to 500 Hz) |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | 2.0 % + 3 (500 Hz to 1 kHz) |
|
1000 V | 1 V | ||
DC volts | 6.000 V | 0.001 V | 0.09 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1500 V | 1 V | 0.15 % + 2 | |
AC mV[1] | 600.0 mV | 0.1 mV | 1.0% + 3 (45 Hz ~ 500 Hz) 2.0% + 3 (500 Hz ~ 1000 Hz) |
DC mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
Continuity | 600 Ω | 1 Ω | |
Resistance | 600.0 Ω | 0.1 Ω | 0.5 % + 4 |
6.000 kΩ | 0.001 kΩ | ||
60.00 kΩ | 0.01 kΩ | ||
600.0 kΩ | 0.1 kΩ | ||
6.000 MΩ | 0.001 MΩ | ||
50.00 MΩ | 0.01 MΩ | 1.5 % + 4 | |
Capacitance | 1000 nF | 1 nF | 1.2 % + 2 |
10.00 μF | 0.01 μF | ||
100.0 μF | 0.1 μF | ||
9999 μF | 1 μF | 10 % typical | |
Frequency | 99.99 Hz | 0.01 Hz | 0.1 % + 2 |
999.9 Hz | 0.1 Hz | ||
9.999 kHz | 0.001 kHz | ||
99.99 kHz | 0.01 kHz | ||
AC VA (45 Hz ~ 500 Hz)[1] | 360.0 VA | 0.1 VA | 2 % + 1.0 VA |
3.600 kVA | 0.001 kVA | 2 % + 0.01 kVA | |
36.00 kVA | 0.01 kVA | 2 % + 0.1 kVA | |
60.00 kVA | 0.01 kVA | 2 % + 0.15 kVA | |
DC VA[1] | 360.0 VA | 0.1 VA | 2 % + 1.0 VA |
3.600 kVA | 0.001 kVA | 2 % + 0.01 kVA | |
36.00 kVA | 0.01 kVA | 2 % + 0.1 kVA | |
90.00 kVA | 0.01 kVA | 2 % + 0.25 kVA | |
Min-max avg | For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration. | ||
For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration. |
[1]Â <1% range, unspecified
Environmental specifications | |
Operating temperature | -10 °C to 60 °C |
Storage temperature | -30 °C to +70 °C |
Humidity (without condensation) | 0 % to 90 %, 10 °C to 30 °C |
0 % to 75 %, 30 °C to 40 °C | |
0 % to 45 %, 40 °C to 60 °C |
Warranty and Protection | |
Electromagnetic compatibility | IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A |
Overvoltage category | CAT III 1500 V, CAT IV 1000 V |
Agency approvals | ETL (AMER and EMEA), CSA (APAC), CE, UK CA |
Drop test | 2 meter (6.5 ft) drop test |
Ingress protection | IP52 |
Warranty | Limited lifetime |
Mechanical and general specifications | |
Counts | 6000 |
Size | 22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in) |
Weight | 0.7 kg (1.5 lb) |
Battery life | > 150 hours typical, without backlight (Alkaline, 3 AA) |
> 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA) |