Additel ADT227 Multifunction Process Calibrator

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Built-in Full Hart Communicator (ADT227-HART)
  • Built-in Barometer
  • Intrinsically safe models available (Ex)
  • Large Smartphone Like Touchscreen User Experience
  • USB Type-C and Bluetooth communications
  • IP67 Rated
  • High Voltage Measurement Capability (±300V AC)
  • True RMS Voltage Meter Capability
  • Dual channel pressure module ports
  • High Static Differential Pressure Measurement 0.002% FS
  • ISO 17025-accredited calibration w/data included

Description

The Additel ADT227 is a cutting-edge, compact multifunction process calibrator designed for efficiency and precision in demanding industrial environments. This instrument represents a significant advancement in calibration technology,

Key Features:

  • Advanced Functionality: Measures and sources a wide range of electrical signals (mA, V, RTD, TC, frequency, resistance), pressure (gauge, differential, absolute), and more.
  • Exceptional Accuracy: Delivers high accuracy for both electrical and pressure measurements, ensuring reliable calibration results.
  • Compact and Portable: Designed for ease of use in the field with a small and lightweight form factor.
  • User-Friendly Interface: Features an intuitive touchscreen interface for easy navigation and operation.
  • Built-in HART Communicator: Enables seamless communication and calibration of HART devices.
  • Rugged and Durable: Built to withstand harsh industrial environments with its robust construction and IP67 rating.
  • Data Logging and Reporting: Stores calibration data and generates comprehensive reports for documentation and traceability.

Applications:

  • Calibration of process transmitters (pressure, temperature, flow, level)
  • Maintenance and troubleshooting of process control systems
  • Commissioning and startup of new installations
  • Field service and on-site instrument repairs

The Additel ADT227 is a powerful and versatile tool for professionals who require a reliable and efficient process calibrator. Its advanced features, compact design, and user-friendly interface make it an ideal choice for various industrial applications.

Additional information

Brand

Additel

Source Accuracy
 

Specifications

ADT227 ADT227Ex
Range Resolution Accuracy Range Resolution Accuracy
 

Voltage DC

-150 to 150 mV 5 μV 0.005%RDG + 15 μV  

0 to 10.5 V

 

0.2 mV

 

0.01%RDG + 0.5 mV

-1.5  to 1.5 V 0.05 mV 0.005%RDG + 0.15 mV
-15 to 15 V 0.5 mV 0.005%RDG + 1.5 mV
Current DC 0 to 25 mA 0.5 μA 0.01%RDG + 1.2 μA 0 to 25 mA 0.5 μA 0.01%RDG + 1.2 μA
 

Resistance

0 to 400 Ω 10 mΩ 0.005%RDG + 20 mΩ 0 to 400 Ω 10 mΩ 0.01%RDG + 20 mΩ
0 to 4000 Ω 100 mΩ 0.01%RDG + 200 mΩ 0 to 4000 Ω 100 mΩ 0.01%RDG + 200 mΩ
 

 

 

Frequency

(Square wave)

(0.01 ~ 5) Hz 0.00001 Hz 0.002%RDG + 0.00002 Hz (0.01 ~ 5) Hz 0.00001 Hz 0.002%RDG + 0.00002 Hz
(5 ~ 50) Hz 0.0001 Hz 0.002%RDG + 0.0002 Hz (5 ~ 50) Hz 0.0001 Hz 0.002%RDG + 0.0002 Hz
(50 ~ 500) Hz 0.001 Hz 0.002%RDG + 0.002 Hz (50 ~ 500) Hz 0.001 Hz 0.002%RDG + 0.002 Hz
(500 ~ 5000) Hz 0.01 Hz 0.002%RDG + 0.02 Hz (500 ~ 5000) Hz 0.01 Hz 0.002%RDG + 0.02 Hz
(5000 ~ 50000) Hz 0.1 Hz 0.002%RDG + 0.2 Hz (5000 ~ 50000) Hz 0.1 Hz 0.002%RDG + 0.2 Hz

 

 

Source Accuracy

 

 

Specifications

 

ADT227

 

ADT227Ex

 

Range

 

Resolution

 

Accuracy

 

Range

 

Resolution

 

Accuracy

 

 

 

 

 

Frequency

(Sine wave & Triangular

wave)

 

(0.1~ 50) Hz

 

0.001 Hz

 

0.002 Hz

 

 

 

 

 

 

N/A

 

(50 ~ 500) Hz

 

0.01 Hz

 

0.02 Hz

 

(500 ~ 5000) Hz

 

0.1 Hz

 

0.2 Hz

 

(5000 ~ 50000) Hz

 

1Hz

 

2 Hz

 

 

 

Duty Cycle

 

(1%~99%)@≤10000Hz

 

0.05%

 

 

 

0.1%kHz+0.1%

 

 

 

Fixed 50%@(0.01~50000)Hz

 

(5%~99%)@≤50000Hz

 

0.5%

 

Voltage mV (TC)

 

-10 to 75 mV

 

1.5 μV

 

0.008%RDG + 3.0 μV

 

-10 to 75 mV

 

1.5 μV

 

0.01%RDG + 3.0 μV

 

 

 

Pulse

 

0 to 9999999

 

1

 

N/A

 

0 to 9999999

 

1

 

N/A

 

Optional rising edge or falling edge, minimum threshold voltage: 2.5V

 

Loop power (max 25mA)

 

24 V

 

N/A

 

±1 V

 

22 V

 

N/A

 

± 10%

 

Measurement Accuracy Cont.
 

Specifications

ADT227 ADT227Ex
Range Resolution Accuracy Range Resolution Accuracy
 

 

Voltage DC

-300 to 300 mV 1 μV 0.005% RDG + 15 μV -300 to 300 mV 1 μV 0.01% RDG + 15 μV
-30 to 30 V 0.1 mV 0.005% RDG + 1.5 mV -30 to 30 V 0.1 mV 0.01% RDG + 1.5 mV
Impedance: -300 mV to 300 mV = > 100 MΩ

-30 V to 30 V = >1 MΩ

 

 

DC High Voltage

-300 to 300 V 10 mV 0.05% RDG + 30 mV  

 

N/A

Maximum input voltage = 300 V, IEC61010 300V CATII
Common mode rejection: >100 dB (at 50 or 60 Hz)
Impedance: > 4 MΩ, DC coupling
 

 

AC High Voltage

300V (40 to 500 Hz) 10 mV 0.5% RDG + 150 mV  

 

N/A

Maximum input voltage = 300 V, IEC61010 300V CATII
9% to 100% of range is suitable for the above accuracy indicators
Impedance: >4 MΩ, <100pF, AC coupling
Current DC -30 to 30 mA 0.1 μA 0.01% RDG + 1.5 μA -30 to 30 mA 0.1 μA 0.01% RDG + 1.2 μA
 

Resistance

(4-Wire)

0 to 400 Ω 1 mΩ 0.005%  RDG + 20 mΩ 0 to 400 Ω 1 mΩ 0.01%  RDG + 20 mΩ
0 to 4000 Ω 10 mΩ 0.01%  RDG + 200 mΩ 0 to 4000 Ω 10 mΩ 0.01%  RDG + 200 mΩ
2-Wire + 50 mΩ, 3-wire+ 10 mΩ
Excitation current: 0.2 mA
 

Voltage mV (TC)

-10 to 75 mV 0.1uV 0.008% RDG + 3.0 μV -10 to 75 mV 0.1uV 0.01% RDG + 3.0 μV
Impedance: >100 MΩ
 

 

 

 

Frequency

(0.01 ~ 5) Hz 0.00001 Hz 0.002%RDG + 0.00002 Hz (0.01 ~ 5) Hz 0.00001 Hz 0.002%RDG + 0.00002 Hz
(5 ~ 50) Hz 0.0001 Hz 0.002%RDG + 0.0002 Hz (5 ~ 50) Hz 0.0001 Hz 0.002%RDG + 0.0002 Hz
(50 ~ 500) Hz 0.001 Hz 0.002%RDG + 0.002 Hz (50 ~ 500) Hz 0.001 Hz 0.002%RDG + 0.002 Hz
(500 ~ 5000) Hz 0.01 Hz 0.002%RDG + 0.02 Hz (500 ~ 5000) Hz 0.01 Hz 0.002%RDG + 0.02 Hz
(5000 ~ 50000) Hz 0.1 Hz 0.002%RDG + 0.2 Hz (5000 ~ 50000) Hz 0.1 Hz 0.002%RDG + 0.2 Hz
Minimum threshold voltage: 2.5 V
Supported units: Hz, kHz, MHz, CPM, CPH, s, ms, μs
 

Duty Cycle

(1%~99%)@≤10000Hz 0.01%  

0.1% kHz + 0.05%

 

N/A

(5%~99%)@≤50000Hz 0.1%
 

Pulse

0 to 9999999 1 N/A 0 to 9999999 1 N/A
Optional rising edge or falling edge, minimum threshold voltage: 2.5V
Switch Supports dry or wet switches. Voltage range of 3 to 30 V. Response speed < 10 ms

General Specifications

Specifications ADT227 ADT227Ex
Operating Temperature -10°C to 50°C -20°C to 50°C
Specification guaranteed

temperature range

10°C to 30°C 10°C to 30°C
Storage Temperature -30°C to 70°C -30°C to 70°C
Humidity <95%, non-condensing <95%, non-condensing
 

Power supply

 

6600mAh, 23.8Wh lithium battery, charging time about 6 hours, battery pack can be charged independently

4000mAh 14.4Wh Explosion-proof lithium battery packcharging time

6~8 hours, battery pack can be charged independently

User interface Icon drive menus Icon driven menus with navigation buttons
 

Ports protection voltage

50V max

(Only for the top ports)

 

30V max

Display 5.0 inch 480 x 800 mm TFT LCD capacitive screen 4.4 inch 640 x 480 mm color display capacitive screen
 

Data logger

500 results,  each result x 100,0000 recordings,  

N/A

Maximum altitude 3000 meters
European Compliance CE Mark
Electrical Connection Ø4mm  sockets and flat mini-jack thermocouple socket
Size 6.97″ x 4.13″ x 2.04″  (177 mm x 105 mm x 52 mm)
Weight 1.6 lb (0.7 kg) 1.65 lb (0.75Kg)
Battery Rechargeable Li-ion battery (included)
Battery Life Typically 12 hours Typically 35 hours
Battery Charge 110V/220V external power adapter included. Battery can be charged external to the unit. Typically charge time is 6-8 hours.
External pressure module Dual channel Serial plug, can connect two digital pressure modules
Warm-up time Full specification performance is achieved after a 10 minute  warm-up  time.
ROHS compliant Rohs II Directive 2011/65/EU, EN50581:2012
Display rate 3 readings per second
Barometric Accuracy

(Built-in barometer)

55Pa
IP protection level IP67, 1 meter drop test
Communication Isolate USB-TYPEC (slave), Bluetooth BLE
User Interface

Localization

English, German, French, Italian, Spanish, Portuguese,

Simplified Chinese, Traditional  Chinese, Japanese,

Russian, Czech, Slovak

 

English,  Simplified Chinese, Traditional  Chinese, Japanese

Calibration ISO 17025 accredited calibration with data
Warranty 3 years

 