• Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
  • Accuracy up to ±0.002 °C.
  • Quick sample readings in as little as 0.3 seconds.
  • 1524 has two channels for simultaneous measurements, doubling productivity.

  • Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
  • Portability: Remains compact and portable, allowing for on-site calibrations at various locations.

  • Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
  • Display eight user-selected data fields from any channel.
  • Log up to 8,000 readings with date and time stamps for data tracking.

  • Temperature ranges from –15 °C to 350 °C.
  • Two wells in each block for simultaneous comparison calibrations.
  • The cold block is calibrated to within ±0.2°C with stability of ±0.05°C. The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C.
  • Rugged, lightweight, and water-resistant enclosure.

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading