• Temperature ranges from –10°C to 375°C.
  • Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
  • Equipped with an RS-232 interface for connectivity.

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

  • Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months).
  • Accredited Cell Intercomaparisons available.

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C

  • Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
  • Accuracy up to ±0.002 °C.
  • Quick sample readings in as little as 0.3 seconds.
  • 1524 has two channels for simultaneous measurements, doubling productivity.

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • World’s smallest portable calibration baths.
  • Calibrates sensors of any size or shape.
  • Stability to ±0.015 °C.
  • Ranges from –30 °C to 200 °C.