- Highly accurate thermo hygrometer and humidity monitor.
- Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
- Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
- Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
- World’s smallest portable calibration baths.
- Calibrates sensors of any size or shape.
- Stability to ±0.015 °C.
- Ranges from –30 °C to 200 °C.
- Accuracy to ±0.25°C and comes with an RS-232 interface.
- The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
- The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
- Features designed with user convenience and productivity in mind.
- Temperature control from 100°C to 1210°C
- Two models to choose from: Reference (ADT878) and Standard (ADT875)
- Display Accuracy of ±1.5°C (ADT878)
- 4 on-board measurement channels (PC option)
- Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
- ISO 17025-accredited calibration w/data included
- Temperature ranges from –15 °C to 350 °C.
- Two wells in each block for simultaneous comparison calibrations.
- The cold block is calibrated to within ±0.2°C with stability of ±0.05°C. The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C.
- Rugged, lightweight, and water-resistant enclosure.
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity checks
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- 5608: –200 °C to 500 °C (80 mm minimum immersion)
- 5609: –200 °C to 670 °C (100 mm minimum immersion)
- ± 0.01 short-term stability
- Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
- Dry-well reference with 90 ° bend
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.