• Reference level performance in accuracy, stability and uniformity
  • Quick to temperature
  • Two-channel readout measures RTDs and TCs, and provides task documentation
  • Full HART communicator (PC Option)
  • Built in automatic annealing feature (ADT878-700 only)
  • ISO 17025-accredited calibration w/data included

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

  • 1502A: accuracy up to ±0.006 °C.
  • 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
  • 1502A: covers –200°C to 962°C
  • 1504: covers 0 to 100°C

  • Operate in temperatures ranging from -200 °C to 160 °C.
  • Accuracy of ± 0.05 °C.
  • Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range.
  • Unique probe seal prevents moisture ingress.
  • Come with NVLAP-accredited calibration.

  • Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
  • Portability: Remains compact and portable, allowing for on-site calibrations at various locations.

  • Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
  • Covers a wide temperature range: 6109A: 35 °C to 250 °C
  • 7109A: -25 °C to 140 °C.
  • Stainless steel casing that withstands harsh cleaning solutions; it’s easy to transport and maintain.

  • Temperature ranges from –15 °C to 350 °C.
  • Two wells in each block for simultaneous comparison calibrations.
  • The cold block is calibrated to within ±0.2°C with stability of ±0.05°C. The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C.
  • Rugged, lightweight, and water-resistant enclosure.

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Displays temperature in °C or °F

  • Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Wide Temperature range from –45 °C to 700 °C