• Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
  • Portability: Remains compact and portable, allowing for on-site calibrations at various locations.

  • 1502A: accuracy up to ±0.006 °C.
  • 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
  • 1502A: covers –200°C to 962°C
  • 1504: covers 0 to 100°C

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

  • Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
  • Covers a wide temperature range: 6109A: 35 °C to 250 °C
  • 7109A: -25 °C to 140 °C.
  • Stainless steel casing that withstands harsh cleaning solutions; it’s easy to transport and maintain.

  • Temperature control from 100°C to 1210°C
  • Two models to choose from: Reference (ADT878) and Standard (ADT875)
  • Display Accuracy of ±1.5°C (ADT878)
  • 4 on-board measurement channels (PC option)
  • Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
  • ISO 17025-accredited calibration w/data included

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

  • Reference level performance in accuracy, stability and uniformity
  • Quick to temperature
  • Two-channel readout measures RTDs and TCs, and provides task documentation
  • Full HART communicator (PC Option)
  • Built in automatic annealing feature (ADT878-700 only)
  • ISO 17025-accredited calibration w/data included

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -50 °C to 160 °C (-58 °F to 320 °F)
  • Displays temperature in °C or °F