• Highly accurate thermo hygrometer and humidity monitor.
  • Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
  • Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
  • Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.

  • Powerful, easy-to-use, high-accuracy temperature calibrator
  • Test and calibrate temperature sensors and transmitters
  • Measures 4 to 20 mA loops and can provide loop power
  • Measures RTDs, thermocouples, ohms, and volts
  • Source/simulates thermocouples, RTDs, volts, and ohms

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Displays temperature in °C or °F

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Reference level performance in accuracy, stability and uniformity
  • Quick to temperature
  • Two-channel readout measures RTDs and TCs, and provides task documentation
  • Full HART communicator (PC Option)
  • Built in automatic annealing feature (ADT878-700 only)
  • ISO 17025-accredited calibration w/data included

  • Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months).
  • Accredited Cell Intercomaparisons available.

  • Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
  • Accuracy up to ±0.002 °C.
  • Quick sample readings in as little as 0.3 seconds.
  • 1524 has two channels for simultaneous measurements, doubling productivity.

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply