- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- Powerful, easy-to-use, high-accuracy temperature calibrator
- Test and calibrate temperature sensors and transmitters
- Measures 4 to 20 mA loops and can provide loop power
- Measures RTDs, thermocouples, ohms, and volts
- Source/simulates thermocouples, RTDs, volts, and ohms
- Accredited radiometric calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Dual-zone control
- Full HART field communicator
- Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
- Set point control by reference
- Self-calibration feature
- ISO 17025-accredited calibration w/data included
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
- Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
- With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
- Low-cost thermocouple furnace.
- NIST-traceable calibration included.
- RS-232 port standard
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
- 5608: –200 °C to 500 °C (80 mm minimum immersion)
- 5609: –200 °C to 670 °C (100 mm minimum immersion)
- ± 0.01 short-term stability
- Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
- Dry-well reference with 90 ° bend
- Highly accurate thermo hygrometer and humidity monitor.
- Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
- Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
- Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.