• Reference level performance in accuracy, stability and uniformity
  • Quick to temperature
  • Two-channel readout measures RTDs and TCs, and provides task documentation
  • Full HART communicator (PC Option)
  • Built in automatic annealing feature (ADT878-700 only)
  • ISO 17025-accredited calibration w/data included

  • 5608: –200 °C to 500 °C (80 mm minimum immersion)
  • 5609: –200 °C to 670 °C (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
  • Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
  • Scan up to 10 channels per second, great for high-speed applications.
  • Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
  • Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -50 °C to 160 °C (-58 °F to 320 °F)
  • Displays temperature in °C or °F

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

  • Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
  • Portability: Remains compact and portable, allowing for on-site calibrations at various locations.

  • Most stable temperature controllers available
  • Resolution as high as 0.00018°C
  • RS-232 interface included for automating applications

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.