• Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025%) for reference class transmitter calibration
  • 30 psi, 150 psi and 300 psi pressure ranges

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.

  • Pressure ranges to 2000 psi (140 bar)
  • 0.015% of reading accuracy (0.008% optional)
  • Screw press for fine pressure control
  • Piston flotation indicator
  • Mounted spirit level with adjustable feet
  • Series 3 non-magnetic stainless steel weights

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

  • Accuracy as low as 0.01%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • ISO 17025-accredited calibration w/data included

  • Easily generate pressure to 10 000 psi (70 MPa)
  • Vernier fine adjustment control
  • Tool-free test connectors for easy, leak free connections
  • Test port connectors include adaptors for common sizes of NPT and BSP