• Complete pressure, temperature, and mA loop calibrator
  • Troubleshoot and calibrate HART smart digital transmitters
  • Create calibration procedures and automatically document results
  • Connect to calibration management software

  • 0.02%, 0.05% FS Accuracy
  • Intrinsically Safe
  • Field Switchable Pressure Module
  • Dual Digital Pressure Module Inputs
  • ISO 17025-accredited calibration w/data included

  • Accuracy as low as 0.01%FS
  • External pressure modules available (measure only)
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • ISO 17025-accredited calibration w/data included

  • Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
  • Ideal for gas flow calibration (custody transfer) applications
  • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
  • Pt100 RTD input for temperature measurement, (probe optional)

  • Automated pressure generation and control to 15,000 psi (1035 Bar)
  • Accuracy to 0.01%FS
  • Control stability ≤ 0.005%FS
  • ISO 17025-accredited calibration w/data included

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

  • Pressure calibrator with built-in electric pump for one-handed pressure calibration
  • Offers best-in-class pressure measurement uncertainty of 0.025%
  • Measures and sources mA with best in class 0.015% accuracy to test valves and I/Ps
  • Calibrates 30 psi and 100 psi pressure ranges
  • Features precision pressure adjustment vernier for easy and accurate pressure calibration

  • A complete family of precision pressure modules
  • Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
  • 8 intrinsically safe models for use with Fluke 718EX or 725EX
  • Reduce errors by digitally sending measurements to calibrators
  • Precision measurements with reference uncertainties up to 0.01%

  • Automated pressure generation and control to 15,000 psi (1035 Bar)
  • Accuracy to 0.01%FS
  • Dual-range calibration
  • Control stability ≤ 0.005%FS
  • Data logging and task management
  • Patented electric pump technology
  • ISO 17025-accredited calibration w/data included

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

  • Automated and self-contained pressure generation and control to 1,500 psi ( 100 bar)
  • Precision accuracy models to 0.01%FS
  • Two removable internal pressure modules for multi-range selection
  • Control stability to 0.003%FS

  • Dual pressure/vacuum capability
  • Bench mount design
  • Built-in handpump as pressure/vacuum source
  • High quality needle valve for fine control
  • Test port adapters that require no PTFE tape or wrenches

  • Pressure ranges to 2000 psi (140 bar)
  • 0.015% of reading accuracy (0.008% optional)
  • Screw press for fine pressure control
  • Piston flotation indicator
  • Mounted spirit level with adjustable feet
  • Series 3 non-magnetic stainless steel weights

  • Easily generate pressure to 10 000 psi (70 MPa)
  • Vernier fine adjustment control
  • Tool-free test connectors for easy, leak free connections
  • Test port connectors include adaptors for common sizes of NPT and BSP

  • High pressure pneumatic operation
  • Screw press for fine pressure adjustments
  • High quality needle valves for fine control
  • Test port adapters which require no PTFE tape or wrenches
  • Sturdy carrying case with lid

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

  • Measure/generate pressures from vacuum to 2 MPa (300 psi, 20 bar).
  • Measure/generate 4 to 20 mA, measures 0 to 30 V DC
  • Generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar).
  • External gas supply up to 2 MPa (300 psi, 20 bar).
  • Fine pressure adjustment.
  • Measurement accuracy of ± (0.025 % reading + 0.01 % FS).

  • Pressure Source and mA Measurement to calibrate pressure devices
  • Built-in pump for sourcing pressure to 300 PSI
  • Easy-to-clean, field-serviceable, integrated pressure pump
  • Built-in switch test for calibrating pressure switches
  • Extend pressure capabilities by using Fluke 750P pressure modules

  • Eliminates the need for weights and piston-cylinder changes.
  • Real-time pressure indication without need for corrections.
  • Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
  • Offers ± 0.02% of reading total one-year measurement uncertainty

  • 0.02% full scale accuracy per 2700G Gauge.
  • Adaptors for NPT, BSP, and metric fittings.
  • Expandable lower range with additional gauges.
  • Battery-operated gauges with line power capability.

  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
  • 1/8 NPT female pressure fitting

  • Automatic pressure generation and regulation to 1000psi
  • Extend measurement range with 750P Series pressure modules
  • Measure temperature with 720RTD probe
  • Absolute and gage pressure modules up to 7MPa.
  • Use the modules to change the Fluke 729Pro to a different output pressure range

  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply
  • Store and recall frequently used calibration set ups

  • Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025%) for reference class transmitter calibration
  • 30 psi, 150 psi and 300 psi pressure ranges

  • Full-featured documenting process calibrator for calibrating and troubleshooting
  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

  • Automatic pressure generation and regulation to 300 psi
  • Configure procedures for pressure transmitters and switches
  • Measure, source, and simulate 4 to 20 mA signals
  • Troubleshoot and calibrate HART smart transmitters
  • Automatically document test results

  • Pressure ranges to 10,000 psi (700 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

  • Pressure ranges to 60,000 psi (4000 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston format
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

  • Pressure ranges to 60,000 psi (4000 bar)
  • Select from two accuracy classes; 0.02% or 0.015% of reading
  • Includes hand pump and intensifier for generating high pressures
  • Tungsten carbide piston and cylinder provides long term stability and durability
  • Mass set can be trimmed to local gravity FOC

  • Generates pressures to 20,000 psi (1400 bar)
  • Operational with a wide range of fluids
  • Built-in hand pump for system priming and large volume applications
  • High quality screw press for fine pressure control

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply