- TRMS value display
- 1 mA / 10 mA resolution
- 25 mm clamp opening
- METRACLIP 41: accurate current measurement from 5 mA to 40 A
- METRACLIP 410: accurate current measurement from 100 mA to 400 A
- Readings of AC current with an accuracy of 0.8 % and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 % and a base resolution of 0.1 V
- MAX/MIN/HOLD mode: displays maximum, minimum or average measured value
- True-RMS clamp meter for measuring current up to 400 A
- Measures AC current to 400 A
- Measures AC voltage and DC voltage to 600 V
- Measures resistance to 4 kΩ with continuity detection
- Measures both AC and DC current, up to 1000A AC/DC.
- Measures resistance of components and circuits.
- Checks for continuity in electrical circuits.
- Measures both voltage and current frequencies.
- 600A AC range, 0.01A high resolution
- Tests voltage, resistance and continuity
- Tests current frequency and voltage frequency
- Tests capacitance and diodes
- Measures both AC and DC current, up to 400A AC.
- Measures resistance of components and circuits.
- Measures both voltage and current frequencies.
- Measures capacitance of capacitors.
- Tests AC voltage and current with the True-rms function.
- 1000A AC range, 0.01A high resolution
- Tests voltage, resistance and continuity
- Tests current frequency and voltage frequency
- 128 Hz notch filter for cable tracing.
- Jaw size: 28 mm.
- Accurate: readings of AC current with an accuracy of 0.8 % and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 % and a base resolution of 0.01 V.
- Voltage measurement from 1 to 1000 V AC TRMS, 1 to 1500 V DC
- Current measurement from 0.1 to 200 A AC, 40 to 65 Hz
- Non-contact and single-pole voltage measurement > 90 V to 1000 V L-L
- Resistance measurement from 0 to 100 kΩ
- Measuring category: CAT IV 600 V, CAT III 1000 V
- Electrical safety per IEC 61010
- TRMS measurement
- Current measurement (AC and DC)
- Voltage measurement (AC and DC)
- Power measurement (W, VA, var and PF)
- Measures both AC and DC current, up to 1000A AC/DC.
- Flexible iFlex® Current Probe Expands the measurement range up to 2500A AC.
- Measures both AC and DC voltages.
- 600A AC/DC range (D model), 0.01A high resolution
- Tests voltage, resistance and continuity
- Tests current frequency and voltage frequency
- Tests capacitance and diodes
- kWHr: Kilo-Watt-Hour recording function (with memory recall).
- Transient protection: it protects user in case of lightning strike or switching surge up to 6.5 kV.
- Safe: CAT IV / 300 V, CAT III / 600 V overvoltage protection.
- 2 measuring ranges: 30 to 300mA and 30 to 300A
- Insensitive to external magnetic fields
- Clip opening: 40 mm
- Compact, handy and lightweight
- True-rms AC/DC current, voltage, temperature, frequency
- Clamp meter, test leads, K-type thermocouple and soft case
- Versatile tool performs most front-line measurement tasks
- 61 mm jaw opening
- Highest resolution of 1 μA, measure up to 60 A
- Max/Min/Average readings and hold function
- CAT III 600V safety rating
- High current: 2000 A DC & AC clamp on measurement.
- Transient protection protects user in case of lightning strike or switching surge up to 12 kV.
- Measures temperature in Celsius up to 1000 °C and in Fahrenheit up to 1832 °F.
- Safe: CAT IV / 1000 V overvoltage protection.
- Current frequency measurement
- Precision down to 0.01A and 0.1V
- 1000A/600A AC/DC current measurement (319/317)
- 600V AC/DC voltage measurement
- 4000Ω resistance measurement
- Measures both AC and DC current, up to 1000A AC/DC.
- Flexible iFlex® Current Probe: Expands the measurement range up to 2500A AC.
- Diode Testing: Tests diodes and other semiconductor devices.
This product is discontinued or reclassified
- TRMS value display
- 1 mA / 10 mA resolution
- Data hold
- 25 mm clamp opening
- 3½ place LCD digital display
- Accuracy: ± 1% ± 5 Digit (50 / 60 Hz)
- DATA HOLD and Max-Min display, automatic shutoff
- Switching between DC and AC measurement
- Measures both AC and DC current, up to 600A AC/DC.
- Flexible iFlex® Current Probe (optional): Expands the measurement range up to 2500A AC.
- Measures both AC and DC voltages.
- High-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- 1500 V DC range with CAT III safety.
- High current range of 2000 A.
- CAT III 1500 V DC and CAT IV 1000 V safety
- Protection against 12 kV transients.
- Temperature measurements up to 1000 °C.
- Measure safely with CAT III 1500 V rated clamp meter
- Sturdy IP54 rated for outdoor use and solar installation
- Work efficiently with dc power measurement, audio polarity and visual continuity
- High specification: readings up to 600 A with excellent accuracy.
- Relative zero mode: relative function for comparing the difference between signals or removing background noise.
- Easy to read: large bright 3-3/4 digits 4000 counts LCD display.
- Electrical safety per IEC 61010
- TRMS measurement
- Current measurement (AC and DC)
- Voltage measurement (AC and DC)
- MIN/MAX/AVG function.
- Peak value.
- 35 mm jaw opening.
- CAT IV / 300 V, CAT III / 600 V overvoltage categories.
- Highest resolution of 1 μA, measure up to 60 A
- 40 mm jaw opening
- Max/Min/Average readings and hold function
- CAT III 600V safety rating
Data hold function.
MIN/MAX/AVG function.
51 mm jaw opening.
CAT IV / 600 V, CAT III / 1000 V overvoltage categories
- Electrical safety per IEC 61010
- TRMS measurement
- Current measurement (AC and DC)
- Voltage measurement (AC and DC)
- Power measurement (W, VA, var and PF)