Testo 300 Kit 2 Flue Gas Analyzer O2 CO H2 up to 8,000 ppm

  • Fast and easy to operate: intuitive measurement menus and fast-response Smart-Touch display
  • Including O2, CO H2-compensated sensor up to 8,000 ppm
  • Large 5-inch HD display – see all the system’s measuring values at a glance
  • In the kit: testo 300 flue gas analyzer, including O2 and CO H2-compensated sensor up to 8,000 ppm, mains unit, basic flue gas probe, spare dirt filters, EasyHeat software, instrument bag
Category:

Description

The Testo 300 Kit 2 is a flue gas analyzer designed for comprehensive combustion analysis of heating systems.

Key Features:

  • Fast and easy to operate: intuitive measurement menus and fast-response Smart-Touch display
  • Including O2, CO H2-compensated sensor up to 8,000 ppm
  • Large 5-inch HD display – see all the system’s measuring values at a glance
  • In the kit: testo 300 flue gas analyzer, including O2 and CO H2-compensated sensor up to 8,000 ppm, mains unit, basic flue gas probe, spare dirt filters, EasyHeat software, instrument bag
  • TÜV-tested: Ensures compliance with relevant safety and performance standards.
  • Enhanced measurement capabilities: Includes O2 and CO sensors for accurate combustion analysis, often with the addition of NO sensors for more in-depth assessments.
  • User-friendly interface: Features an intuitive touch display and easy-to-navigate menus.
  • Compact and portable: Designed for convenient transport and on-site use.
  • Includes: Flue gas analyzer, basic flue gas probe, instrument case, and essential accessories.

Applications:

  • Heating system installation and maintenance: Assess combustion efficiency and identify potential issues.
  • Troubleshooting: Diagnose problems with heating systems based on flue gas analysis.
  • Compliance checks: Verify that systems meet environmental regulations and safety standards.
  • Advanced analysis: Conduct more in-depth investigations due to the inclusion of NO sensors (specific to models with NO capabilities).

With Testo 300 Kit 2, you will be equipped for the most important measurements involving heating systems: the TÜV-tested testo 300 flue gas analyzer is supplied with O2 CO H2 sensor up to 8,000 ppm, basic flue gas probe, instrument case and practical accessories.

Additional information

Brand

Testo

Measurement parameter Measuring range Accuracy 1  digit) Resolution
O2  measurement 0 to 21 vol. % ±0.2  vol. % 0.1 vol. %
CO measurement

(without H2  compensation)

0 to 4,000  ppm ±20 ppm  (0 to 400 ppm)

±5 % of m.v. (401 to 2,000  ppm)

±10 % of m.v. (2,001 to 4,000  ppm)

1 ppm
CO measurement

(with  H2  compensation)

0 to 8,000  ppm ±10 ppm  or ± 10 % of m.v. (0 to 200 ppm)

±20 ppm  or ± 5 % of m.v. (201 to 2,000  ppm)

±10 % of m.v. (2,001 to 8,000  ppm)

1 ppm
CO measurement

(without H2  compensation with  dilution)

0 to 15,000 ppm ±200  ppm  or ± 20 % of m.v. 1 ppm
CO measurement

(with  H2  compensation and  dilution)

0 to 30,000 ppm ±100  ppm  or ± 10 % of m.v. 1 ppm
COlow  measurement

(with  H2  compensation)

0 to 500 ppm ±2 ppm  (0 to 40 ppm)

±5 % of m.v. (remaining  meas. range)

0.1 ppm
NO measurement 0 to 3,000  ppm ±5 ppm  (0 to 100 ppm)

±5 % of m.v. (101 to 2,000  ppm)

±10 % of m.v. (2,001 to 3,000  ppm)

1 ppm
NOlow  measurement 0 to 300 ppm ±2 ppm  (0 to 39.9  ppm)

±5 % of m.v. (40 to 300 ppm)

0.1 ppm
Efficiency testing (Eta) 0 to 120 % 0.1 %
Flue  gas loss 0 to 99.9  % 0.1 %
CO2  determination

(digital calculation from  O2)

Display range

0 to CO2   max.

±0.2  vol. % 0.1 vol. %
Draught measurement -9.99  to +40 hPa ±0.005  hPa  (0 to 0.1 hPa)

±0.02  hPa  (0.1 to +3.00  hPa)

±1.5  % of m.v. (+3.01 to +40 hPa)

0.001  hPa  (0 to 0.1 hPa)

0.01  hPa  (remaining  meas. range)

4 Pa  measurement

(for instruments with  dilution)

-50 to +50 Pa ±0.3  Pa  (< 10 Pa)

±3 % of m.v. (remaining  meas. range)

0.1 Pa
Pressure measurement -100  to +200  hPa ±0.5  hPa  (0 to +50.0  hPa)

±1 % of m.v. (+50.1 to +100.0  hPa)

±1.5  % of m.v. (+100.1  to +200  hPa)

0.01  hPa
Temperature (instrument) -40 to +1,200  °C ±0.5  °C (0.0 to +100.0  °C)

±0.5  % of m.v. (remaining  meas. range)

0.1 °C (-40 to +999.9  °C)

1 °C (remaining  meas. range)

Ambient CO measurement

(internal/flue gas probe)

0 to 2,000  ppm ±10 ppm  (0 to 100 ppm)

±10 % of m.v. (101 to 2,000  ppm)

1 ppm
Ambient CO measurement

(external with  CO probe)

0 to 500 ppm ±3 ppm  (0 to 29 ppm)

±10 % of m.v. (30 to 500 ppm)

1 ppm

Related Products