Rotronic HC2A-S(M)-HH Probe Hydrogen Peroxide Environments
- Measures relative humidity, temperature and dew point
- With HYGROMER® HH1-SK sensor for hydrogen peroxide environments
- Highest possible measuring accuracy
- Conforms to GAMP
- Description
- Additional information
- Specifications
Description
The Rotronic HC2A-S(M)-HH is a specialized humidity and temperature probe designed to withstand the harsh conditions of hydrogen peroxide sterilization processes. This makes it ideal for applications in cleanrooms, incubators, and other environments where regular sterilization is required.
Key Features:
- H2O2 Resistance: Equipped with the HYGROMER® HH1-SK sensor, this probe is specifically designed to resist the corrosive effects of hydrogen peroxide.
- High Accuracy: Delivers precise measurements of humidity and temperature, ensuring accurate data collection.
- Wide Operating Range: Operates reliably in a broad range of temperatures and humidity levels, accommodating diverse applications.
- Robust Design: Built to withstand harsh environments, including the effects of sterilization processes.
- Fast Response Time: Provides quick and accurate readings, enabling real-time monitoring and control.
- Interchangeable Sensors: Allows for easy replacement of sensors in the field, minimizing downtime and reducing maintenance costs.
Benefits:
- Reliable Performance: Ensures accurate and reliable measurements in hydrogen peroxide environments.
- Extended Sensor Life: The specialized sensor design significantly extends the life of the probe.
- Improved Process Control: Enables precise control of humidity and temperature during sterilization processes.
- Enhanced Safety: Contributes to a safer working environment by monitoring critical environmental parameters.
By choosing the Rotronic HC2A-S(M)-HH, you can ensure the reliability and accuracy of your humidity and temperature measurements in hydrogen peroxide sterilization environments.
Additional information
Brand | Rotronic |
---|
Order code | HC2A–S–HH / HC2A–SM–HH |
Type | Humidity-Temperature-Probe for HH |
Humidity Sensor | HYGROMER HH1-SK |
Temperature Sensor | PT100 1/3 class B |
PeakLoad H2O2 | 880 ppm / 1200 mg/m³ |
Operating humidity | 0…100 %rh |
Operating temperature | 0…60 °C |
Accuracy @10…30°C before and after diffusion phase |
±1.0 %rh, ±0.1 K |
Analogue output | 2 x 0…1 VDC |
Analogue output parameter |
• Humidity (default)
• Temperature (default) • Dew-point (setting with HygroSoft) • Frost-point (setting with HygroSoft) |
Analog output scaling |
• Humidity (0…100 %rh = 0…1 V)
• Temperature (-40…60 °C = 0…1 V) • Freely settable with HygroSoft |
Timing | Measurement interval of 1 s |
Air Chip 3000 |
Saves adjustment data so that probes can be interchanged without re-adjust- ing |
Housing material | Polycarbonat / Stainless steel 1.4301 |
Filter | No Filter |
Audit Trail | FDA CFR21 Part 11 /GAMP comatible |