Kambic Climatic Chamber Low Temperature is a renowned manufacturer of high-quality climatic chambers. Here’s an overview of their key features and characteristics :
Key Features Kambic Climatic Chamber Low Temperature:
- Precision Temperature Control:
- Wide Temperature Ranges: Capable of achieving and maintaining precise temperatures across a wide range, typically from -70°C to +180°C or even higher depending on the model.
- Accuracy and Stability: High accuracy and stability are critical for reliable testing.
- Humidity Control:
- Precise Control: Many models offer precise control of relative humidity (RH) levels, often from 10% to 98% RH.
- Uniformity: Ensures consistent humidity levels throughout the test chamber.
- Rapid Temperature Cycling:
- Fast Transitions: Some models are designed for rapid temperature transitions, crucial for accelerated testing.
- Uniformity:
- Excellent Temperature and Humidity Uniformity: Ensures consistent conditions within the test chamber, minimizing variations that could affect test results.
- Data Logging and Monitoring:
- Advanced Control Systems: Often equipped with advanced control systems that allow for data logging of temperature, humidity, and other parameters.
- Real-time Monitoring: Enables real-time monitoring and adjustments of test conditions.
- Safety Features:
- Overtemperature Protection: Built-in safety mechanisms to prevent overheating.
- Emergency Shut-off: Mechanisms to quickly shut down the chamber in case of malfunctions.
- Customizable Configurations:
- Available in various sizes and configurations to meet specific testing requirements.
Applications:
Kambic climatic chambers Low Temperature are widely used across various industries, including:
- Electronics: Testing the reliability of electronic components and devices under extreme temperature and humidity conditions.
- Automotive: Evaluating the performance and durability of automotive components, such as engines, electronics, and materials.
- Aerospace: Testing the reliability of aerospace components and systems under extreme temperature and pressure conditions.
- Pharmaceuticals: Testing the stability and shelf life of pharmaceuticals.
- Materials Science: Characterizing the behavior of materials under different environmental conditions.
Additional information
| Brand | Kambic |
|---|
| KK-68 CHLT | KK-190 CHLT | KK-340 CHLT | |
| External dimensions
(WxHxD) [mm] |
650 x 1223 x 796 |
835 x 1661 x 951 |
835 x 1881 x 1126 |
| Internal dimensions
(WxHxD) [mm] |
410 x 475 x 350 |
600 x 615 x 510 |
600 x 835 x 685 |
| Volume [L] | ~ 68 | ~ 190 | ~ 340 |
| Temperature range [°C] | – 40 …+ 180 | – 40 …+ 180 | – 40 …+ 180 |
| Heat up rate [°C/min]
(according to EN 60068-3-5) |
4,0 |
2,0 |
1,5 |
| Cool down rate [°C/min]
(according to EN 60068-3-5) |
2,5 |
2,5 |
2,5 |
| Temperature display res [°C] | 0.1 | 0.1 | 0.1 |
| Temperature set res. [°C] | 0.1 | 0.1 | 0.1 |
|
Temperature stability [°C] |
± 0.2°C @ – 40°C
± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.1°C @ 180°C |
± 0.2°C @ – 40°C
± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.15°C @ 180°C |
± 0.2°C @ – 40°C
± 0.05°C @ 50°C 50%Rh ± 0.05°C @ 90 °C 90%Rh ± 0.15°C @ 180°C |
|
Temperature uniformity [°C] |
± 1.0°C @ – 40°C
± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 2.5°C @ 180°C |
± 0.5°C @ – 40°C
± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 0.5°C @ -40°C
± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
|
Heat compensation [W] |
~ 100 @ – 30 °C
~ 800 @ – 5 °C ~ 1500 @ + 20 °C |
~ 350 @ – 30 °C
~ 1500 @ – 5 °C ~ 3000 @ + 20 °C |
~ 350 @ – 30 °C
~ 1500 @ – 5 °C ~ 3000 @ + 20 °C |
| Rh range [%] | 10…98 | 10…98 | 10…98 |
| Rh display resolution [%] | 0.1 | 0.1 | 0.1 |
| Rh set resolution [%] | 1 | 1 | 1 |
| Rh stability [%] | ± 0.3 % @ 50 °C 50 % Rh
± 0.3 % @ 90 °C 90 % Rh |
± 0.3 % @ 50 °C 50 % Rh
± 0.3 % @ 90 °C 90 % Rh |
± 0.3 % @ 50 °C 50 % Rh
± 0.3 % @ 90 °C 90 % Rh |
| Temperature control | PID (PT-100) | PID (PT-100) | PID (PT-100) |
|
Relative humidity control |
Dew point RH control
via Rh capacitive sensor/ dry air purge for extended range |
Dew point RH control via
Rh capacitive sensor/ dry air purge for extended range |
Dew point RH control
via Rh capacitive sensor/ dry air purge for extended range |
| Power supply | 230V 50/60 Hz | 230V 50/60 Hz | 230V 50/60 Hz |
| Wattage [W] | 3500 | 3600 | 3600 |
| Interface | USB and Ethernet | USB and Ethernet | USB and Ethernet |
| Shelve | 1 (max 6) | 1 (max 8) | 1 (max 8) |
| Shelve capacity [kg] | 25 | 35 | 35 |
| Max capacity [kg] | 40 | 80 | 100 |
| Water reservoir capacity [L] | 8.2 | 19.6 | 19.6 |
| Water consumption [L/24h] (operating at +90 °C / 90 %Rh) |
~1 |
~1.5 |
~1.5 |
| Observation window | As standard | As standard | As standard |
| Access port [mm] | Ø 50 (left side) | Ø 50 (left side) | Ø 50 (left side) |
| Noise [dBA] @ 1 m distance | 58 | 60 | 60 |
| Weight [kg] | 195 | 278 | 324 |
*All performance in controlled environment (Tambient = 22 °C ± 3 °C)!
*Accessories might affect performance!
| KK-500 CHLT | KK-1000 CHLT | |
| External dimensions
(WxHxD) [mm] |
1035 x 1880 x 1381 |
1235 x 1928 x 1579 |
| Internal dimensions
(WxHxD) [mm] |
800 x 835 x 800 |
1000 x 1035 x 1000 |
| Volume [L] | ~ 500 | ~ 1000 |
| Temperature range [°C] | – 40 …+ 180 | – 40 …+ 180 |
| Heat up rate [°C/min]
(according to EN 60068-3-5) |
3.0 |
3.0 |
| Cool down rate [°C/min]
(according to EN 60068-3-5) |
2.5 |
2.5 |
| Temperature display res [°C] | 0.1 | 0.1 |
| Temperature set res. [°C] | 0.1 | 0.1 |
|
Temperature stability [°C] |
± 0.2°C @ – 40°C
± 0.05°C @ 50°C 50% Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 180°C |
± 0.2°C @ – 40°C
± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 180°C |
|
Temperature uniformity [°C] |
± 0.5°C @ – 40°C
± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 0.5°C @ – 40°C
± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 9 0% Rh ± 1.5°C @ 180°C |
|
Heat compensation [W] |
~ 500 @ – 30 °C
~ 2500 @ – 5 °C ~ 3000 @ + 20 °C |
~ 500 @ – 30 °C
~ 3000 @ – 5 °C ~ 5000 @ + 20 °C |
| Rh range [%] | 10…98 | 10…98 |
| Rh display resolution [%] | 0.1 | 0.1 |
| Rh set resolution [%] | 1 | 1 |
| Rh stability [%] | ± 0.3 % @ 50 °C 50 % Rh
± 0.3 % @ 90 °C 90 % Rh |
± 0.3 % @ 50 °C 50 % Rh
± 0.3 % @ 90 °C 90 % Rh |
| Temperature control | PID (PT-100) | PID (PT-100) |
|
Relative humidity control |
Dew point RH control via Rh capacitive sensor/ dry air purge for extended range | Dew point RH control via Rh capacitive sensor/ dry air purge for extended range |
| Power supply | 3x400V 50/60Hz | 3x400V 50/60Hz |
| Wattage [W] | 9000 | 12000 |
| Interface | USB and Ethernet | USB and Ethernet |
| Shelve | 1 (max 8) | 1 (max 8) |
| Shelve capacity [kg] | 50 | 50 |
| Max capacity [kg] | 150 | 200 |
| Water reservoir capacity [L] | 29.3 | 39.3 |
| Water consumption [L/24h]
(operating at +90 °C / 90 %Rh) |
~1.5 |
~2.0 |
| Observation window | As standard | As standard |
| Access port [mm] | Ø 50 (left side) | Ø 50 (left side) |
| Noise [dBA] @ 1 m distance | 62 | 62 |
| Weight [kg] | 435 | 604 |
*All performance in controlled environment (Tambient = 22 °C ± 3 °C)!
*Accessories might affect performance!