Kambic Climatic Chamber Low Temperature (- 40 °C …+ 180 °C)

  • Temperature & Relative humidity-controlled test polygon
  • Material temperature & Rh resistance and product testing
  • Maintaining superior temperature & Rh stability
  • Sample conditioning prior to other tests
  • Data loggers and sensors calibration
  • World class metrology performance
  • Accelerated ageing
  • Stress tests
Category:

Description

Kambic Climatic Chamber Low Temperature is a renowned manufacturer of high-quality climatic chambers. Here’s an overview of their key features and characteristics :

Key Features Kambic Climatic Chamber Low Temperature:

  • Precision Temperature Control:
    • Wide Temperature Ranges: Capable of achieving and maintaining precise temperatures across a wide range, typically from -70°C to +180°C or even higher depending on the model.
    • Accuracy and Stability: High accuracy and stability are critical for reliable testing.
  • Humidity Control:
    • Precise Control: Many models offer precise control of relative humidity (RH) levels, often from 10% to 98% RH.
    • Uniformity: Ensures consistent humidity levels throughout the test chamber.
  • Rapid Temperature Cycling:
    • Fast Transitions: Some models are designed for rapid temperature transitions, crucial for accelerated testing.
  • Uniformity:
    • Excellent Temperature and Humidity Uniformity: Ensures consistent conditions within the test chamber, minimizing variations that could affect test results.
  • Data Logging and Monitoring:
    • Advanced Control Systems: Often equipped with advanced control systems that allow for data logging of temperature, humidity, and other parameters.
    • Real-time Monitoring: Enables real-time monitoring and adjustments of test conditions.
  • Safety Features:
    • Overtemperature Protection: Built-in safety mechanisms to prevent overheating.
    • Emergency Shut-off: Mechanisms to quickly shut down the chamber in case of malfunctions.
  • Customizable Configurations:
    • Available in various sizes and configurations to meet specific testing requirements.

Applications:

Kambic climatic chambers Low Temperature are widely used across various industries, including:

  • Electronics: Testing the reliability of electronic components and devices under extreme temperature and humidity conditions.
  • Automotive: Evaluating the performance and durability of automotive components, such as engines, electronics, and materials.
  • Aerospace: Testing the reliability of aerospace components and systems under extreme temperature and pressure conditions.
  • Pharmaceuticals: Testing the stability and shelf life of pharmaceuticals.
  • Materials Science: Characterizing the behavior of materials under different environmental conditions.

Additional information

Brand

Kambic

KK-68 CHLT KK-190 CHLT KK-340 CHLT
External dimensions

(WxHxD) [mm]

 

650 x 1223 x 796

 

835 x 1661 x 951

 

835 x 1881 x 1126

Internal dimensions

(WxHxD) [mm]

 

410 x 475 x 350

 

600 x 615 x 510

 

600 x 835 x 685

Volume [L] ~ 68 ~ 190 ~ 340
Temperature range [°C] – 40 …+ 180 – 40 …+ 180 – 40 …+ 180
Heat up rate [°C/min]

(according to EN 60068-3-5)

 

4,0

 

2,0

 

1,5

Cool down rate [°C/min]

(according to EN 60068-3-5)

 

2,5

 

2,5

 

2,5

Temperature display res [°C] 0.1 0.1 0.1
Temperature set res. [°C] 0.1 0.1 0.1
 

 

Temperature stability [°C]

± 0.2°C @ – 40°C

± 0.05°C @ 50°C 50 % Rh

± 0.05°C @ 90°C 90 % Rh

± 0.1°C @ 180°C

± 0.2°C @ – 40°C

± 0.05°C @ 50°C 50 % Rh

± 0.05°C @ 90°C 90 % Rh

± 0.15°C @ 180°C

± 0.2°C @ – 40°C

± 0.05°C @ 50°C 50%Rh

± 0.05°C @ 90 °C 90%Rh

± 0.15°C @ 180°C

 

 

Temperature uniformity [°C]

± 1.0°C @ – 40°C

± 0.3°C @ 50°C 50 % Rh

± 0.3°C @ 90°C 90 % Rh

± 2.5°C @ 180°C

± 0.5°C @ – 40°C

± 0.3°C @ 50°C 50 % Rh

± 0.3°C @ 90°C 90 % Rh

± 1.5°C @ 180°C

± 0.5°C @ -40°C

± 0.3°C @ 50°C 50 % Rh

± 0.3°C @ 90°C 90 % Rh

± 1.5°C @ 180°C

 

Heat compensation [W]

~ 100 @ – 30 °C

~ 800 @ – 5 °C

~ 1500 @ + 20 °C

~ 350 @ – 30 °C

~ 1500 @ – 5 °C

~ 3000 @ + 20 °C

~ 350 @ – 30 °C

~ 1500 @ – 5 °C

~ 3000 @ + 20 °C

Rh range [%] 10…98 10…98 10…98
Rh display resolution [%] 0.1 0.1 0.1
Rh set resolution [%] 1 1 1
Rh stability [%] ± 0.3 % @ 50 °C 50 % Rh

± 0.3 % @ 90 °C 90 % Rh

± 0.3 % @ 50 °C 50 % Rh

± 0.3 % @ 90 °C 90 % Rh

± 0.3 % @ 50 °C 50 % Rh

± 0.3 % @ 90 °C 90 % Rh

Temperature control PID (PT-100) PID (PT-100) PID (PT-100)
 

 

Relative humidity control

Dew point RH control

via Rh capacitive sensor/ dry air purge for extended range

Dew point RH control via

Rh capacitive sensor/ dry air purge for extended range

Dew point RH control

via Rh capacitive sensor/ dry air purge for extended range

Power supply 230V 50/60 Hz 230V 50/60 Hz 230V 50/60 Hz
Wattage [W] 3500 3600 3600
Interface USB and Ethernet USB and Ethernet USB and Ethernet
Shelve 1 (max 6) 1 (max 8) 1 (max 8)
Shelve capacity [kg] 25 35 35
Max capacity [kg] 40 80 100
Water reservoir capacity [L] 8.2 19.6 19.6
Water consumption [L/24h] (operating at +90 °C / 90 %Rh)  

~1

 

~1.5

 

~1.5

Observation window As standard As standard As standard
Access port [mm] Ø 50 (left side) Ø 50 (left side) Ø 50 (left side)
Noise [dBA] @ 1 m distance 58 60 60
Weight [kg] 195 278 324

*All performance in controlled environment (Tambient = 22 °C ± 3 °C)!
*Accessories might affect performance!

 

KK-500 CHLT KK-1000 CHLT
External dimensions

(WxHxD) [mm]

 

1035 x 1880 x 1381

 

1235 x 1928 x 1579

Internal dimensions

(WxHxD) [mm]

 

800 x 835 x 800

 

1000 x 1035 x 1000

Volume [L] ~ 500 ~ 1000
Temperature range [°C] – 40 …+ 180 – 40 …+ 180
Heat  up rate [°C/min]

(according to EN 60068-3-5)

 

3.0

 

3.0

Cool down rate  [°C/min]

(according to EN 60068-3-5)

 

2.5

 

2.5

Temperature display res [°C] 0.1 0.1
Temperature set res. [°C] 0.1 0.1
 

Temperature stability [°C]

± 0.2°C @ – 40°C

± 0.05°C @ 50°C 50% Rh

± 0.05°C @ 90°C 90 % Rh

± 0.2°C @ 180°C

± 0.2°C @ – 40°C

± 0.05°C @ 50°C 50 % Rh

± 0.05°C @ 90°C 90 % Rh

± 0.2°C @ 180°C

 

Temperature uniformity [°C]

± 0.5°C @ – 40°C

± 0.3°C @ 50°C 50 % Rh

± 0.3°C @ 90°C 90 % Rh

± 1.5°C @ 180°C

± 0.5°C @ – 40°C

± 0.3°C @ 50°C 50 % Rh

± 0.3°C @ 90°C 9 0% Rh

± 1.5°C @ 180°C

 

Heat compensation [W]

~ 500 @ – 30 °C

~ 2500 @ – 5 °C

~ 3000 @ + 20 °C

~ 500 @ – 30 °C

~ 3000 @ – 5 °C

~ 5000 @ + 20 °C

Rh range [%] 10…98 10…98
Rh display resolution [%] 0.1 0.1
Rh set resolution [%] 1 1
Rh stability [%] ± 0.3 % @ 50 °C 50 % Rh

± 0.3 % @ 90 °C 90 % Rh

± 0.3 % @ 50 °C 50 % Rh

± 0.3 % @ 90 °C 90 % Rh

Temperature control PID (PT-100) PID (PT-100)
 

Relative humidity control

Dew point RH control via Rh capacitive sensor/ dry air purge for extended range Dew point RH control via Rh capacitive sensor/ dry air purge for extended range
Power supply 3x400V 50/60Hz 3x400V 50/60Hz
Wattage [W] 9000 12000
Interface USB and Ethernet USB and Ethernet
Shelve 1 (max 8) 1 (max 8)
Shelve capacity [kg] 50 50
Max capacity [kg] 150 200
Water reservoir capacity [L] 29.3 39.3
Water consumption [L/24h]

(operating at +90 °C / 90 %Rh)

 

~1.5

 

~2.0

Observation window As standard As standard
Access port [mm] Ø 50 (left side) Ø 50 (left side)
Noise [dBA] @ 1 m distance 62 62
Weight [kg] 435 604

*All performance in controlled environment (Tambient = 22 °C ± 3 °C)!