Gossen METRACLIP 62 Digital Current Clamp for Leakage
- 3½ place LCD digital display
- Accuracy: ± 1% ± 5 Digit (50 / 60 Hz)
- DATA HOLD and Max-Min display, automatic shutoff
- Switching between DC and AC measurement
- Robust case
- In synthetic material bag
- Description
- Additional information
- Specifications
Description
The METRACLIP 62 is a digital clamp meter from Gossen Metrawatt specifically designed for measuring leakage and charging currents.
Key Features:
- 3 measuring ranges 1 mA . . . 10 A AC TRMS / DC
- High resolution due to hall effect sensor
- Switch-over between DC and AC measurements
- Zero balancing for DC measurements
- Storage of reference values for AC measurements
- Display of maximum or minimum current measured value
- Storage of measured value (DATA HOLD)
- Battery saving circuit
- Insensitive to magnetic interference fields thanks to double shielding
- High Sensitivity: Measures very low currents with high accuracy, making it ideal for detecting subtle leakage currents.
- Contactless Measurement: Enables safe and efficient current measurement without touching the conductor.
- Compact and Portable: Designed for easy handling and use in various environments.
- Shielded Opening: Minimizes the influence of external magnetic fields on the measurement, ensuring accurate readings.
Applications:
- Measurement of leakage current at grounded conductors
- Measurement of leakage current at single-phase or 3-phase systems
- Measurement of line current
- Measurement of charging current
- Leakage Current Detection: Detects and diagnoses electrical faults and ground faults.
- Battery Charging Current Measurement: Monitors charging currents in various battery systems.
- Electrical Troubleshooting: Helps pinpoint the source of electrical problems.
In essence, the METRACLIP 62 is a specialized tool for professionals who require precise and reliable measurements of small currents in electrical systems.
Additional information
Brand | Gossen Metrawatt |
---|
Characteristic Values
METRACLIP 41 | METRACLIP 62 | METRACLIP 410 | METRACLIP 61 | |
Item number | M320A | M311F | M320B | M311D |
Continuity test | ||||
Max. voltage measuring circuit category | 300Volt | 300Volt | 300Volt | |
Diode test | ||||
Frequency range alternating current | 15Hertz – 400Hertz | 50Hertz – 60Hertz | 50Hertz – 60Hertz | |
Phase sequence determination | ||||
AC measuring method | TRMS | TRMS | TRMS | Mean value |
Indication | Digital | Digital | Digital | Digital |
Analogue bar graph display | ||||
Measuring range selection | Automatic | Manual | Automatic | Manual |
Current measuring range, DC | 4 – 40 | 1 – 10 | 100 – 400 | |
Current measuring range, AC | 4 – 40 | 1 – 10 | 100 – 400 | 0.03 – 300 |
Type of current | AC/DC | AC/DC | AC/DC | AC |
True RMS measurement | x | x | x | |
Voltage measurement, AC | ||||
Voltage measurement, DC | ||||
Resistance measuring range | ||||
Power measuring | ||||
Leakage current measuring | x | x | ||
Harmonics measurement | ||||
Measurement in cables with for- and back conductor | ||||
Jaw opening | 25 | 18 | 25 | 40 |
Version as adapter to connect to multi meter | ||||
Interface | ||||
Measuring circuit category | CAT III | CAT III | CAT III | CAT III |
Intrinsic uncertainty of the measured value in % | 1Percentage | 1.2Percentage | ||
Measured value memory | HOLD |