Fluke P3200 Hydraulic Deadweight Tester
- Pressure ranges to 10,000 psi (700 bar)
- 0.015% of reading accuracy standard (0.008% optional)
- Single or dual piston formats
- Built-in hand pumps standard
- Mounted spirit level with adjustable feet
- Units can be trimmed to local gravity FOC
- Description
- Additional information
- Specifications
Description
The Fluke Calibration P3200 Series are high-accuracy, hydraulic deadweight testers designed for calibrating a wide range of pressure instruments.
Key Features:
- Pressure ranges to 10,000 psi (700 bar)
- 0.015% of reading accuracy standard (0.008% optional)
- Single or dual piston formats
- Built-in hand pumps standard
- Mounted spirit level with adjustable feet
- Units can be trimmed to local gravity FOCHigh Accuracy: Offers exceptional accuracy, typically better than 0.015% of reading, ensuring precise and reliable pressure measurements.
- Versatility: Available in various configurations to cover a wide range of pressure ranges, from low to high pressures.
- Rugged and Durable: Designed for demanding laboratory and field environments, with robust construction and reliable performance.
- Traceability: Calibrations are traceable to national and international standards, ensuring the accuracy and reliability of your measurements.
- Easy to Use: User-friendly design and intuitive operation simplify the calibration process.
Applications:
- Calibration Laboratories: Primary standard for calibrating pressure instruments, including gauges, transmitters, transducers, and switches.
- Industrial Environments: Used for on-site calibration of critical process instrumentation in various industries, such as oil and gas, chemical, and manufacturing.
- Research and Development: Employed in research and development laboratories for precise pressure measurements and calibrations.
The Fluke Calibration P3200 Series are high-performance pressure standards that provide exceptional accuracy and reliability for critical pressure calibration applications.
Additional information
| Brand | Fluke Calibration |
|---|
Specifications: Fluke Calibration P3200 Hydraulic Deadweight Tester
| Pressure Ranges | |
| Distilled water operated | Ranges to 10,000 psi (700 bar) |
| Accuracy | |
| Accuracy1 | ±0.015% of reading (±0.008% optional) |
| 1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range. | |
| Materials of Construction | |
| Standard weight material | Series 3 non-magnetic austenitic stainless steel |
| Weight density | 7.8 g/cm³ |
| Optional fractional weights | Solution heat treated aluminum |
| Weight density | 2.7 g/cm³ |
| Piston material | Tungsten carbide with nickel binder Density- 15.0 g/cm³ |
| Cylinder material | Hardened martensitic steel Tungsten carbide (water above 500 psi, 35 bar) |
| Thermal coefficients of expansion | Oil piston/cylinder 16.5 ppm/°C Water (above 500 psi, 35 bar) 11 ppm/°C |
| General | |
| Test port adaptors | 1/8, 1/4, 3/8 and 1/2 NPT or BSP |
| Instrument weight | 36 lbs (16 kg) |
| Instrument size (W x D x H) | 17.5 x 12 x 8.5 in (440 x 300 x 215 mm) |
| Mass set weight (typical) | 80 lbs (36 kg) |
| Reservoir volume | 150 cc |
| Screw press displacement | 5.5 cc |
| Pump displacement | 4.7 cc per stroke |
| O-ring seal materials | Buna N as standard, Viton and EPDM available |
| Weight Increments | |
| Minimum standard weight increments | Up to 500 psi (35 bar): 1 psi (0.1 bar) 500 to 5000 psi (35 to 350 bar): 10 psi (1 bar) 5000 to 20,000 psi (350 to 1400 bar): 20 psi (2 bar) Model P3112: 1 psi (0.1 bar) |
| Optional fractional weights | Up to 500 psi (35 bar): 0.1 psi (0.01 bar) 500 to 5000 psi (35 to 350 bar): 1 psi (0.1 bar) 5000 to 20,000 psi (350 to 1400 bar): 2 psi (0.2 bar) |
| Operating Fluids | |
| Operating fluids | Distilled or deionized water |
| Options | |
| PressCal software | Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments |
| Fluids | Instruments can be supplied for use with Skydrol or brake fluids. Due to the aggressive nature of these fluids the standard nitrile seals and the acrylic reservoir tube will be replaced by either Viton or EPDM seals (as applicable) and an aluminum reservoir tube. For these or any other specialty fluid applications, please consult the factory. |
Related Products
- 0.02%, 0.05% FS Accuracy
- Intrinsically Safe
- Field Switchable Pressure Module
- Dual Digital Pressure Module Inputs
- ISO 17025-accredited calibration w/data included
- Automated and self-contained pressure generation and control to 1,500 psi ( 100 bar)
- Precision accuracy models to 0.01%FS
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.003%FS
- Automated pressure generation and control to 15,000 psi (1035 Bar)
- Accuracy to 0.01%FS
- Dual-range calibration
- Control stability ≤ 0.005%FS
- Data logging and task management
- Patented electric pump technology
- ISO 17025-accredited calibration w/data included
- Eliminates the need for weights and piston-cylinder changes.
- Real-time pressure indication without need for corrections.
- Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
- Offers ± 0.02% of reading total one-year measurement uncertainty.
- Pressure Source and mA Measurement to calibrate pressure devices
- Built-in pump for sourcing pressure to 300 PSI
- Easy-to-clean, field-serviceable, integrated pressure pump
- Built-in switch test for calibrating pressure switches
- Extend pressure capabilities by using Fluke 750P pressure modules
- Offers best-in-class pressure measurement uncertainty of 0.025%
- Measures and sources mA with best in class 0.015% accuracy to test valves and I/Ps
- Calibrates 30 psi and 100 psi pressure ranges
- Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
- Ideal for gas flow calibration (custody transfer) applications
- Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
- Pt100 RTD input for temperature measurement, (probe optional)
- Calibration of both temperature and pressure transmitters
- Measure/source/simulate mA loop parameters
- Measure and source mA, Volts DC, frequency, and resistance
- Built-in 24 V loop power supply
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
- Automatic pressure generation and regulation to 1000psi
- Extend measurement range with 750P Series pressure modules
- Measure temperature with 720RTD probe
- Absolute and gage pressure modules up to 7MPa.
- Use the modules to change the Fluke 729Pro to a different output pressure range
- A complete family of precision pressure modules
- Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
- 8 intrinsically safe models for use with Fluke 718EX or 725EX
- Reduce errors by digitally sending measurements to calibrators
- Precision measurements with reference uncertainties up to 0.01%
- Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement
- Eliminates the need for weights and piston-cylinder changes.
- Real-time pressure indication without need for corrections.
- Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
- Offers ± 0.02% of reading total one-year measurement uncertainty
- Pressure ranges to 2000 psi (140 bar)
- 0.015% of reading accuracy (0.008% optional)
- Screw press for fine pressure control
- Piston flotation indicator
- Mounted spirit level with adjustable feet
- Series 3 non-magnetic stainless steel weights
- Pressure ranges to 60,000 psi (4000 bar)
- 0.015% of reading accuracy standard (0.008% optional)
- Single or dual piston format
- Built-in hand pumps standard
- Mounted spirit level with adjustable feet
- Units can be trimmed to local gravity FOC
- Pressure ranges to 60,000 psi (4000 bar)
- Select from two accuracy classes; 0.02% or 0.015% of reading
- Includes hand pump and intensifier for generating high pressures
- Tungsten carbide piston and cylinder provides long term stability and durability
- Mass set can be trimmed to local gravity FOC
- Dual pressure/vacuum capability
- Bench mount design
- Built-in handpump as pressure/vacuum source
- High quality needle valve for fine control
- Test port adapters that require no PTFE tape or wrenches
- 0.02% full scale accuracy per 2700G Gauge.
- Adaptors for NPT, BSP, and metric fittings.
- Expandable lower range with additional gauges.
- Battery-operated gauges with line power capability.
- High pressure pneumatic operation
- Screw press for fine pressure adjustments
- High quality needle valves for fine control
- Test port adapters which require no PTFE tape or wrenches
- Sturdy carrying case with lid
- Easily generate pressure to 10 000 psi (70 MPa)
- Vernier fine adjustment control
- Tool-free test connectors for easy, leak free connections
- Test port connectors include adaptors for common sizes of NPT and BSP