Fluke Norma 6000 Series Portable Power Analyzers

  • Portable and Lightweight: Compact design and battery power for field use.
  • High-Precision Measurements: Accurate measurement of voltage, current, power, power factor, energy consumption, and more.
  • Advanced Harmonic Analysis: Identifies and quantifies harmonic distortion up to the 40th harmonic.
  • Fast Fourier Transform (FFT) Analysis: Provides a detailed frequency spectrum analysis.
  • Transient Recording: Captures short-duration power quality disturbances for detailed analysis.
  • Dynamic Measurements: Measures power quality parameters under varying load conditions.
  • User-Friendly Interface: Intuitive interface for easy setup and operation.
  • Flexible Configuration Options: Customizable to suit specific application needs.
  • Robust and Durable Design: Built to withstand demanding environments.
  • Powerful Analysis Software: In-depth analysis and reporting capabilities.

Description

The Fluke Norma 6000 Series is a family of portable, high-precision power analyzers designed to provide accurate and reliable power measurements in various applications. These analyzers are ideal for field technicians and engineers who need to make measurements directly at the load, eliminating the need for bulky and fragile benchtop equipment.

Key Features:

  • Portable and Lightweight: Compact design and battery power enable easy field use.
  • High-Precision Measurements: Accurate measurement of voltage, current, power, power factor, energy consumption, and more.
  • Advanced Harmonic Analysis: Identifies and quantifies harmonic distortion up to the 40th harmonic.
  • Fast Fourier Transform (FFT) Analysis: Provides a detailed frequency spectrum analysis.
  • Transient Recording: Captures short-duration power quality disturbances for detailed analysis.
  • Dynamic Measurements: Measures power quality parameters under varying load conditions.
  • User-Friendly Interface: Intuitive interface for easy setup and operation.
  • Flexible Configuration Options: Customizable to suit specific application needs.
  • Powerful Analysis Software: In-depth analysis and reporting capabilities for comprehensive data interpretation.

Applications:

  • Motor and Drive Testing: Analyzing motor performance, efficiency, and power quality.
  • Power Supply Testing: Assessing the performance of power supplies under different load conditions.
  • Renewable Energy Systems: Monitoring the performance of solar, wind, and other renewable energy systems.
  • Power Distribution Systems: Identifying and troubleshooting power quality problems in distribution systems.
  • Research and Development: Developing and testing new power electronics devices and systems.

With its advanced features and portability, the Fluke Norma 6000 Series empowers engineers and technicians to make informed decisions, optimize system performance, and ensure reliable operation.

Additional information

Brand

Fluke

Specifications: Fluke Norma 6000 Series Portable Power Analyzers

Inputs Norma 6003 3 Voltage + 3 Current
Norma 6003+ 3 Voltage + 3 Current + 1 Motor
Norma 6004 4 Voltage + 4 Current
Norma 6004+ 4 Voltage + 4 Current + 1 Motor
Sample rate 200ks/s
Measurement update rate 100ms, 200ms, 500ms, 1s
Dimensions (H * W * L) 298mm x 215m x 96mm
Weight 3.5 kg (7.7 lbs)
Display 5.7 inch, TFT LCD, 640×480
Operating temperature -10 °C to +50 °C
Storage temperature -30 °C to +60 °C
Operating humidity Non-condensing (< 10 °C )
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
Operating altitude 2000m
Storage altitude 12000m
Ingress protection IP 50 (Terminals mated) according to IEC 60529:
Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Warranty 1 Year
Communication Interface USB/RS485
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
PC Software Fluke Power Analyzer software
Storage Capacity 32GB
Data trend storage rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function

 

Electrical Specifications
Voltage
Range 10 V, 100 V, 1000 V
Crest Factor CF ≤ 2
Maximum Voltage 10 % overload
Input Impedance 2M Ω/10pF (Typical)
Temperature Coefficient 0.05 * (Spec)/k
Bandwidth 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
CMRR 120 dB @ 50/60 Hz

 

Accuracy (% reading + % range)
Range 1000 V 100 V 10 V
DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10kHz) 5 + 0.5 5 + 0.5 5 + 0.5
Current
Crest Factor CF ≤ 2
Temperature Coefficient 0.05 x (Spec)/k
Overload capacity 10 % overload
CMRR 120 dB @ 50/60 Hz
Shunt (current input)
Measuring Range 0.1 A, 1 A, 10 A
Input Impedance 0.025 Ω (Typical)
Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range 0.1 V, 1 V, 10 V
Input Impedance 100k Ω/100pF (Typical)
Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz

 

Accuracy (% reading + % range)
Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V
DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0.1 0.1+0.2 0.1+1
AC (10Hz to 1kHz) 0.1+0.1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5
AC (10kHz) 5+1 5+1 5+1 5+1 5+1 5+1
Motor Module (Torque and Speed)
Voltage Range ± 10 V dc, 10 % overload
Voltage Channels 2
Input Impedance 1.1M Ω (Typical)
Accuracy at dc 0.1 % range + 0.1 % reading
Pulse Channels 3
Pulse Logic High Threshold 2 V (Typical)
Pulse Logic Low Threshold 0.8 V (Typical)
Maximum Pulse Frequency 100 kHz
Motor Module (Torque and Speed)
Frequency Accuracy 0.05 % range + 0.05 % reading
Harmonics 100 (50Hz/60Hz)
Calculation method FFT/Interpolation

 