Fluke iSee Mobile Thermal Camera TC01A/TC01B
- 256 x 192 pixels, detailed image quality
- Up to 550 °C, suitable to use in many applications
- ±2% or ±2 °C accuracy, reliable and stable
- 25 Hz frame rate for smooth video recording
- Description
- Additional information
- Specifications
- Models
Description
The Fluke iSee Mobile Thermal Camera is a compact and powerful tool designed to help you identify potential problems in electrical systems, HVAC systems, and building structures. This innovative device offers a wide range of features and benefits:
Key Features:
- High-Quality Thermal Imaging: Captures detailed thermal images with a 256 x 192 pixel resolution, allowing you to visualize temperature differences and identify potential issues.
- Wide Temperature Range: Measures temperatures from -10°C to 550°C, making it suitable for a variety of applications.
- High Thermal Sensitivity: Detects even subtle temperature variations with a thermal sensitivity of 50 mK (0.05°C).
- Real-Time Analysis: Quickly identify hot spots and cold spots with real-time temperature measurements and analysis tools.
- Easy-to-Use App: The intuitive app allows you to capture, analyze, and share thermal images and videos.
- Compact and Lightweight Design: Easily portable and convenient to use.
- Durable Construction: Built to withstand harsh environments.
Benefits:
- Preventative Maintenance: Identify potential problems before they escalate into costly failures.
- Improved Efficiency: Optimize energy usage by identifying inefficient areas.
- Enhanced Safety: Detect electrical hazards and other safety risks.
- Faster Troubleshooting: Quickly pinpoint the root cause of problems.
- Professional-Grade Performance: Offers features and performance comparable to larger, more expensive thermal cameras.
The Fluke iSee is a valuable tool for anyone who needs to perform thermal inspections, including electricians, HVAC technicians, building inspectors, and homeowners. With its compact size, powerful features, and easy-to-use app, the iSee makes thermal imaging accessible to everyone.
Additional information
| Brand | Fluke |
|---|
Specifications: Fluke iSee™ Mobile Thermal Camera – TC01A/TC01B
| TC01A | TC01B | |
| Performance Specifications | ||
| IR resolution | 256 x 192 | |
| Pixel size | 12 μm | |
| Temperature range | -10 °C to 550 °C/14 °F to 1022 °F | -20 °C to 550 °C/-4 °F to 1022 °F |
| Temperature accuracy | ± 2 % of rdg or ± 2 °C/3.6 °F, whichever is greater
(@ 23 °C ± 5°C/73.4 °F ± 9 °F ambient temperature) |
|
| Temperature measurement distance | 0.25 m to 5 m
(* -20 ℃/-4 °F to 10 ℃/50 °F, only for 0.25 m to 3 m) |
|
| Frame rate | 25 Hz | |
| Warm-up time | 1 minute | |
| Focal length | Fixed focal length: 3.2 mm | |
| Shutter mode | Internal | |
| Thermal sensitivity (NETD) | 50 mK | |
| Spectral range | 8 to 14 μm | |
| Field of view (H x V) | 56° x 42° | |
| Spatial resolution | 3.81 mrad | |
| General Specifications | ||
| USB interface | Type-C | Lightning |
| Operating temperature | 0 ℃ to 40 ℃/32 °F to 104 °F | |
| Storage temperature | -30 ℃ to 60 ℃/–22 °F to 140 °F | |
| Operating humidity | 10 % to 90 % RH, non-condensing | |
| Power consumption | 350 mW (Typical) | 200 mW (Typical) |
| Drop test | 1 m/3.3 ft | |
| Ingress protection | IEC 60529: IP54
(with the protective cover for Type C) |
IEC 60529: IP56 |
| Operating altitude | 2 000 m/6 562 ft | |
| Storage altitude | 12 000 m/39 370 ft | |
| Dimensions (L x W x H) | 60 x 33.5 x 11.2 mm/2.36 x 1.32 x 0.44 in | |
| EMC Environment | International
IEC 61326-1: Electromagnetic environment for portable equipments CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply net- work that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Korea (KCC) Class A Equipment (Industrial Broadcasting and Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. United States (FCC) 47 CFR 15 Subpart B. This product is considered an exempt device per clause 15.103. |
|
Models: Fluke iSee™ Mobile Thermal Camera – TC01A/TC01B
- Fluke TC01A Mobile Thermal Camera (Part#: 5518338)
- Packaging Box
- User’s Manual
Related Products
- MATLAB and LabVIEW software compatibility allows users to integrate thermal data, images and videos to support R&D analysis
- 320 x 240 resolution
- See the details you need with optional smart lenses: 2x and 4x telephoto, macro and wide angle
- This product has been discontinued or reclassified
- Continuous touchscreen IR-Fusion™
- Can withstand drop up to 2 meter
- Water and dust resistant—IP54 enclosure rating
- Automatically organize and file thermal images with Fluke Connect™ Asset Tagging
- 120 x 90 infrared resolution
- 256 x 192 infrared resolution
- Touchscreen IR Fusion™
- Manual and fixed focus
- Measure up to 550 °C
- Engineered to withstand 2 meter drop
- 320 x 240 resolution
- 2 meter drop test
- IR Fusion™ technology for context
- Fixed focus
- Measure up to 400 °C
- Rugged, superbly engineered 640 x 480 thermal imaging camera
- Provides large 5.7-inch responsive LCD touchscreen with 150% more viewing area than 3.5-inch screen
- Features 240° rotating screen for unmatched shooting flexibility
- Provides 4x the pixel data with on-camera SuperResolution to create a 1280 x 960 resolution image
- Detector Type: VOx
- Infrared Resolution: 320×240 pixels
- Wavelength Range: 7.5 µm to 14 µm
- Temperature Range: -20°C to 550°C
- Accuracy: ±2°C or ±2% (whichever is greater)
- NETD (Noise Equivalent Temperature Difference): ≤ 40 mK
- Field of View (FOV): 36° x 27°
- Focus Mode: Focus-free
- Digital Zoom: 1.1x to 8x
- Sensor Type: VOx, 7.5 to 14μm
- Infrared Resolution: 320 x 240 pixels
- Super Resolution: Upgradable to 640 x 480 pixels
- Temperature Range: -40°C to 650°C
- Temperature Accuracy: ±2°C or ±2% (whichever is greater)
- Thermal Sensitivity (NETD): ≤45 mK
- Frame Rate: 30 Hz / 9 Hz
- Focal Length: 10.5 mm
- Field of View (FOV): 25° x 19°
- IFOV: 1.36 mrad
- Minimum Object Distance: 0.1 m
- D:S: 735:1
- Focusing Modes: Manual, Automatic, Touch Autofocus, Continuous Autofocus
- Digital Zoom: 1.1x to 10x
- Display: 3.5-inch LCD touchscreen
- Battery Life: Up to 5 hours
- Storage: Micro SD card slot
- Connectivity: Wi-Fi, Bluetooth, USB-C
- Sensor Type: VOx, 12μm
- Infrared Resolution: 384 x 288 pixels
- Temperature Range: -40°C to 650°C
- Temperature Accuracy: ±2°C or ±2% (whichever is greater)
- Thermal Sensitivity (NETD): ≤45 mK
- Frame Rate: 30 Hz
- Focal Length: 10.5 mm
- Field of View (FOV): 25° x 19°
- Minimum Focus Distance: 15 cm
- Focusing Modes: Manual, Automatic, Touch Autofocus, Continuous Autofocus
- Digital Zoom: 1.1x to 10x
- Display: 3.5-inch LCD touchscreen
- Battery Life: Up to 5 hours
- Storage: Micro SD card slot
- Connectivity: Wi-Fi, Bluetooth, USB-C
- Sensor Type: VOx, 12μm
- Infrared Resolution: 480 x 360 pixels
- Temperature Range: -40°C to 650°C
- Temperature Accuracy: ±2°C or ±2% (whichever is greater)
- Thermal Sensitivity (NETD): ≤45 mK
- Frame Rate: 30 Hz
- Focal Length: 17.7 mm
- Field of View (FOV): 12° x 9°
- Minimum Focus Distance: 15 cm
- Focusing Modes: Manual, Automatic, Touch Autofocus, Continuous Autofocus
- Digital Zoom: 1.1x to 16x
- Display: 3.5-inch LCD touchscreen
- IR Detector: 640×480 pixels, NETD ≤40 mK
- Visible Light Camera: 13MP
- Display: 4.3-inch LCD touchscreen
- Focusing Modes: Manual, auto, continuous, 2 custom
- Temperature Range: -20°C to +600°C
- Frame Rate: 30 Hz / 9 Hz
- IP Rating: IP54
- With a rotatable design, the display rotates 270 and the lens rotates 70 upwards for easy viewing angle
- Upgraded visible light camera, flagship model up to 13 million pixels, supports infrared and visual imaging dual-channel video recording
- -40°C ~ 2000°C ultra-wide temperature range, support automatic switching, suitable for more application scenarios
- 1024x768Infrared module
- 13MillionVisible light
- 30mkNETD
- IP54Encapsulation
- Infrared Resolution: 1280 x 1024 pixels
- Detector Type: VOx, 7.5 to 14μm
- Frame Rate: 30Hz / 9Hz
- Field of View: 25° x 19°
- IFOV: 0.71mrad
- Focusing: Manual / Automatic / Touch autofocus / Continuous autofocus
- Digital Zoom: 1.1x to 40x
- Measurement Range: -40°C to 150°C, 0°C to 650°C, Optional 400°C to 2500°C (High temperature lens required)
- Measurement Accuracy: ±1°C or ±1%, whichever is greater
- Infrared Resolution: 1024 x 768 pixels
- Detector Type: VOx, 7.5 to 14μm
- Frame Rate: 30Hz / 9Hz
- Field of View: 25° x 19°
- IFOV: 0.43mrad
- Focusing: Manual / Automatic / Touch autofocus / Continuous autofocus
- Digital Zoom: 1.1x to 50x
- Measurement Range: -40°C to 150°C, 0°C to 800°C
- Measurement Accuracy: ±1°C or ±1%, whichever is greater
- Infrared Resolution: 120 x 90 pixels
- Thermal Sensitivity: ≤45 mK
- Field of View: 50° x 38°
- Measurement Range: -20°C to 150°C, 100°C to 400°C (auto-switching)
- Measurement Accuracy: ±2°C or ±2%, whichever is greater
- Image Storage: 32GB removable TF card
- Display: 2.4″ LCD
- Focusing: Focus-free
- IR resolution: 256 x 192 (49 152 pixels), 2MP Visual Resolution
- Temperature measurement range : -20°C to 550°C (-4°F to 1022°F) Accuracy: Max (± 2°C/3.6°F, ± 2%), for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)
- 3.2″ 480 × 640 Resolution LCD Screen
- Up to 6 hours continuous running
- Thermal resolution: 384 × 288 (110,592 pixels), NETD: < 35 mK (@ 30°C, F#=1.0)
- Temperature measurement range: -20°C to 650°C (-4°F to 1202°F)
- 1.× to 8.× continuous digital zoom
- GPS & compass annotation functions
- Long-distance laser light supplement for thermography targets
- Thermal resolution: 480 x 360 (172,800 pixels),NETD : < 35 mK (@ 30 °C, F#=1.0)
- Temperature measurement range : -20 °C to 2000 °C (-4 °F to 3632 °F)
- 1.x to 8.x continuous digital zoom
- GPS & compass annotation functions
- Long-distance laser light supplement for thermography targets
- Very fast frame rate 50 hz;
- Temperature in °C, °F or K;
- Thermal and visible light videos;
- Simultaneous storage of visible light and IR images for video;
- Live transmission of video over HDMI or USB;
- Included 8 GB micro SD card (for more than 6000 images);