Fluke ii915 Acoustic Imager
- Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
- LeakQ™ Mode: Quantifies leak severity.
- PDQ™ Mode: Assesses the severity of electrical discharges.
- MecQ™ Mode: Proactively addresses potential problems in rotating mechanical components.
- Large Touchscreen Display: Clear and detailed view of the acoustic image.
- Rugged Design: Durable and reliable for tough conditions.
- Intuitive Interface: Easy-to-use controls and menus.
- Fluke Connect Compatibility: Remote sharing and analysis of data.
- High-Resolution Sensor: Captures detailed acoustic images.
- Wide Frequency Range: Detects a broad range of sound frequencies.
- Adjustable Sensitivity: Customize detection sensitivity to specific needs.
- Image and Video Recording: Capture and save images and videos for documentation.
- Description
- Additional information
- Specifications
- Models
Description
The Fluke ii915 Acoustic Imager is a powerful tool designed to help you quickly and accurately detect, locate, and quantify sound leaks. With its advanced features and intuitive design, the ii915 makes it easy to identify potential problems in your industrial operations.
Key Features:
- Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
- LeakQ™ Mode: Quantifies leak severity, providing estimates of leak size and potential cost savings.
- PDQ™ Mode: Assesses the severity of electrical discharges.
- MecQ™ Mode: Proactively addresses potential problems in rotating mechanical components.
- Large Touchscreen Display: The 7-inch LCD touchscreen offers a clear and detailed view of the acoustic image.
- Rugged Design: Built to withstand tough industrial environments, ensuring durability and reliability.
- Intuitive Interface: Easy-to-use controls and menus make it simple to operate, even for beginners.
- Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.
Applications:
- Industrial Maintenance: Detect leaks in compressed air, gas, and steam systems.
- HVAC: Identify air leaks and optimize system performance.
- Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
- Electrical Maintenance: Detect arcing and corona discharge.
- Quality Control: Monitor product quality and identify noise sources.
By visualizing sound, the Fluke ii915 helps you save energy, reduce costs, and improve overall operational efficiency. Its advanced features and intuitive design make it a valuable tool for professionals in various industries.
Additional information
Brand | Fluke |
---|
Specifications: Fluke ii915 Acoustic Imager
Specifications | |
Sensors | |
Frequency band | 2 kHz to 100 kHz 2 kHz to 52 kHz |
Detection range1 | 0.5 to > 120 meters (1.6 to > 393 feet) |
Field of view (FOV) | 63°± 5° |
Nominal frame rate | 25 FPS |
Built-in digital camera (visible light) | |
Field of view (FOV) | 63°±5° |
Focus | Fixed lens |
Zoom | 3 x digital zoom |
Resolution | 5 MP |
Display | |
Size | 7″ LCD with backlight, sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic image | SoundMapTM image |
Image storage | |
Storage capacity | 32 GB (> 8,000 pictures / > 1,600 videos) |
Image format | Blended visual and SoundMapTM .JPG or .PNG |
Video format | Blended visual and SoundMapTM .MP4 |
Video length | Up to 5 minutes |
Digital export | USB-C for data transfer |
Acoustic measurements | |
Measurement range (typical) | 12.1 to 114.6 dB SPL (± 1 dB SPL 2 kHz) 4.4 to 101.2 dB SPL (± 2 dB SPL 19 kHz) 12.8 to 119.2 dB SPL (± 1 dB SPL 35 kHz) 19.8 to 116.1 dB SPL (± 3 dB SPL 52 kHz) 41.4 to 129.0 dB SPL (± 1 dB SPL 80 kHz) 54.4 to 135.5 dB SPL (± 1 dB SPL 100 kHz) |
Classification and quantification | |
LeakQTM | Leak size scale, Leak rate, and Leak cost estimation |
PDQ ModeTM | Partial discharge type classification |
MecQTM | Mechanical anomaly detection |
Auto max/min dB gain | Auto or manual, user selectable |
Frequency band selection | User selectable through user-made presets or manual entry |
Battery | |
Battery | Rechargeable and field replaceable Li-ion battery |
Battery life | 6 hours |
Battery charging time | ~3,5 hours |
Battery charging system | Internal (USB-C) |
Software | |
Ease of use | Intuitive user interface |
Acoustics: Show dB scale | On/Off |
Acoustics: Min/Max dB | Manual/Auto |
Acoustics: Profiles | Preset capture profiles |
Acoustics: High frequency | Yes |
Acoustics: Multiple sources | Show single or multiple sources |
Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red |
Palette: Overly transparency | Yes: 1-100% |
Grayscale mode | Yes |
Centerpoint markers | On/Off |
Trend graphs | Frequency and dB scale |
Spotmarkers | dB level reading at center point of image |
Leak values | Leak costs, Leak volume, LeakQTM scale (1-10)2 |
Master admin menu | Yes |
Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
Photo notes | Up to 4 photos notes for reference |
Asset inspection status | ‘As left’, ‘As found’, ‘Undetermined’ |
Asset ID | Text input and automatic QR code based asset ID identification |
Actions annotation | Action requirements, Action priority level, Action notes |
Other | Operating conditions, Weather notes |
General Specifications | |
Tripod holder / connector | Yes: 1/4″-20 |
USB | 2 x USB-C |
Wireless | Wifi |
Operating Temperature | -10 to 45 °C (14 to 113 °F) |
Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed |
Relative humidity | 10 to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
Weight (battery included) | 2 kg (4.4 pounds) |
Ingress Protection (IP) | IP40 |
Fluke Premium Care | Premium Care Standard3 |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
Safety | |
General safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) |
USA (FCC) | 47 CFR 15 sub part B. This product is considered an exempt device per clause 15.103 |
¹ Depending on ambient conditions ² 1-10 Scale (independent of Leak Type) ³ Subject to regional availability (www.fluke.com/premiumcare) |
Models: Fluke ii915 Acoustic Imager
Includes:
- Fluke ii915 Acoustic Imager
- USB-C Charger with country-specific connectors.
- Rugged lithium-ion smart battery pack
- USB-C cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap
- Sensor array protector