Fluke ii910 Precision Acoustic Imager
- SoundSight™ Technology: Converts sound waves into visual images.
- High-Resolution Display: Clear and detailed view of the acoustic image.
- Rugged Design: Durable and reliable for tough conditions.
- Intuitive Interface: Easy-to-use controls and menus.
- Fluke Connect Compatibility: Remote sharing and analysis of data.
- Wide Frequency Range: Detects a broad range of sound frequencies, including those associated with partial discharge and mechanical issues.
- Adjustable Sensitivity: Customize detection sensitivity to specific needs.
- Image and Video Recording: Capture and save images and videos for documentation.
- Description
- Additional information
- Specifications
- Models
Description
The Fluke ii910 Precision Acoustic Imager is a powerful tool designed to locate partial discharge, corona discharge, as well as gas and vacuum leaks. This innovative device converts sound waves into visual images, making it easy to identify and pinpoint the source of the sound.
Key Features:
- SoundSight™ Technology: This technology allows you to see sound leaks and other acoustic anomalies, making it easier to diagnose problems.
- High-Resolution Display: The 7-inch LCD touchscreen provides a clear and detailed view of the acoustic image.
- Rugged Design: Built to withstand tough industrial environments, ensuring durability and reliability.
- Intuitive Interface: Easy-to-use controls and menus make it simple to operate, even for beginners.
- Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.
- Wide Frequency Range: Detects a broad range of sound frequencies, including those associated with partial discharge and mechanical issues.
- Adjustable Sensitivity: Customize detection sensitivity to specific needs.
- Image and Video Recording: Capture and save images and videos for documentation.
Applications:
- Electrical Maintenance: Detect partial discharge and corona discharge in electrical equipment.
- Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
- HVAC: Identify air leaks and optimize system performance.
- Industrial Maintenance: Detect leaks in compressed air, gas, and vacuum systems.
The Fluke ii910 is a versatile and powerful tool that can help you save energy, reduce costs, and improve overall operational efficiency.
Additional information
Brand | Fluke |
---|
Specifications: Fluke ii910 Precision Acoustic Imager
Sensors | |
Frequency band | 2 kHz to 100 kHz |
Detection range | 0.5 to > 120 meters (1.6 to > 393 feet)* |
Field of View | 63 ° ± 5 ° |
Nominal frame rate | 25 FPS |
*Depending on ambient conditions |
Built-in digital camera (visible light) | |
Field of View (FOV) | 63 ° ± 5 ° |
Focus | Fixed lens |
Display | |
Size | 7″ LCD with backlight, under-sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic image | Yes, SoundMap™ image |
Image storage | |
Storage capacity | Internal memory with the capacity for 999 picture files and 20 video files |
Image format | Blended visual and SoundMap™.JPG or .PNG |
Video format | Blended visual and SoundMap™.MP4 |
Video length | 5 minutes maximum |
Digital export | USB-C for data transfer |
Acoustic Measurements | |
Measurement range | 12.1 dB SPL to 114.6 dB SPL ±1 dB SPL 2 kHz 4.4 dB SPL to 101.2 dB SPL ±2 dB SPL 19 kHz 12.8 dB SPL to 119.2 dB SPL ±1 dB SPL 35 kHz 19.8 dB SPL to 116.1 dB SPL ±3 dB SPL 52 kHz 41.4 dB SPL to 129.0 dB SPL ±1 dB SPL 80 kHz 54.4 dB SPL to 135.5 dB SPL ±1 dB SPL 100 kHz |
Auto max/min dB gain | Auto or manual, user selectable |
Frequency band selection | User selectable through user-made presets or manual entry |
Software | |
Ease of use | Intuitive user interface |
Trend graphs | Frequency and dB scale |
Spot markers | dB level reading at center point of the image |
Battery | |
Batteries (field-replaceable, rechargeable) | 2 x Rechargeable Li-ion, Fluke BP291 |
Battery life | 6 hours/battery (product includes spare battery) |
Battery charging time | 3 hours |
Battery charging system | External dual-bay charger, EDBC 290 |
General Specifications | |
Standard palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating temperature | 0 °C to 40 °C (32 °F to 104 °F) |
Storage temperature | -20 °C to 70 °C (-4 °F to 158 °F) Without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Size (H x W x L) | 186 x 322 x 68 mm (7.3 x 12.7 x 2.7 inches) |
Weight (battery included) | 2.15 kg (4.74 lbs) |
Ingress Protection (IP) | IP40 protection |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
Safety | |
General safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Models: Fluke ii910 Precision Acoustic Imager
Includes:
- Imager
- AC power supply and battery pack charger (including universal AC adapters)
- Two rugged lithium ion smart battery packs
- USB cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap