Fluke ii910 Precision Acoustic Imager

  • SoundSight™ Technology: Converts sound waves into visual images.
  • High-Resolution Display: Clear and detailed view of the acoustic image.
  • Rugged Design: Durable and reliable for tough conditions.
  • Intuitive Interface: Easy-to-use controls and menus.
  • Fluke Connect Compatibility: Remote sharing and analysis of data.
  • Wide Frequency Range: Detects a broad range of sound frequencies, including those associated with partial discharge and mechanical issues.
  • Adjustable Sensitivity: Customize detection sensitivity to specific needs.
  • Image and Video Recording: Capture and save images and videos for documentation.
Category:

Description

The Fluke ii910 Precision Acoustic Imager is a powerful tool designed to locate partial discharge, corona discharge, as well as gas and vacuum leaks. This innovative device converts sound waves into visual images, making it easy to identify and pinpoint the source of the sound.

Key Features:

  • SoundSight™ Technology: This technology allows you to see sound leaks and other acoustic anomalies, making it easier to diagnose problems.
  • High-Resolution Display: The 7-inch LCD touchscreen provides a clear and detailed view of the acoustic image.
  • Rugged Design: Built to withstand tough industrial environments, ensuring durability and reliability.
  • Intuitive Interface: Easy-to-use controls and menus make it simple to operate, even for beginners.
  • Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.
  • Wide Frequency Range: Detects a broad range of sound frequencies, including those associated with partial discharge and mechanical issues.
  • Adjustable Sensitivity: Customize detection sensitivity to specific needs.
  • Image and Video Recording: Capture and save images and videos for documentation.

Applications:

  • Electrical Maintenance: Detect partial discharge and corona discharge in electrical equipment.
  • Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
  • HVAC: Identify air leaks and optimize system performance.
  • Industrial Maintenance: Detect leaks in compressed air, gas, and vacuum systems.

The Fluke ii910 is a versatile and powerful tool that can help you save energy, reduce costs, and improve overall operational efficiency.

Additional information

Brand

Fluke

Specifications: Fluke ii910 Precision Acoustic Imager

Sensors
Frequency band 2 kHz to 100 kHz
Detection range 0.5 to > 120 meters (1.6 to > 393 feet)*
Field of View 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions

 

Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °
Focus Fixed lens

 

Display
Size 7″ LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic image Yes, SoundMap™ image

 

Image storage
Storage capacity Internal memory with the capacity for 999 picture files and 20 video files
Image format Blended visual and SoundMap™.JPG or .PNG
Video format Blended visual and SoundMap™.MP4
Video length 5 minutes maximum
Digital export USB-C for data transfer

 

Acoustic Measurements
Measurement range 12.1 dB SPL to 114.6 dB SPL ±1 dB SPL 2 kHz
4.4 dB SPL to 101.2 dB SPL ±2 dB SPL 19 kHz
12.8 dB SPL to 119.2 dB SPL ±1 dB SPL 35 kHz
19.8 dB SPL to 116.1 dB SPL ±3 dB SPL 52 kHz
41.4 dB SPL to 129.0 dB SPL ±1 dB SPL 80 kHz
54.4 dB SPL to 135.5 dB SPL ±1 dB SPL 100 kHz
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry

 

Software
Ease of use Intuitive user interface
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image

 

Battery
Batteries (field-replaceable, rechargeable) 2 x Rechargeable Li-ion, Fluke BP291
Battery life 6 hours/battery (product includes spare battery)
Battery charging time 3 hours
Battery charging system External dual-bay charger, EDBC 290

 

General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red
Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity 10 % to 95 % non-condensing
Size (H x W x L) 186 x 322  x 68 mm (7.3 x 12.7 x 2.7 inches)
Weight (battery included) 2.15 kg (4.74 lbs)
Ingress Protection (IP) IP40 protection
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliant Yes

 

Safety
General safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

 

Models: Fluke ii910 Precision Acoustic Imager
Includes:

  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap