Fluke ii900 Industrial Acoustic Imager

  • SoundMap™ Technology: Converts sound waves into visual images.
  • LeakQ™ Mode: Quantifies leak severity.
  • Large Touchscreen Display: Clear and detailed view of the acoustic image.
  • Rugged Design: Durable and reliable for tough conditions.
  • Intuitive Interface: Easy-to-use controls and menus.
  • Fluke Connect Compatibility: Remote sharing and analysis of data.
  • High-Resolution Sensor: Captures detailed acoustic images.
  • Wide Frequency Range: Detects a broad range of sound frequencies.
  • Adjustable Sensitivity: Customize detection sensitivity to specific needs.
  • Image and Video Recording: Capture and save images and videos for documentation.
Category:

Description

The Fluke ii900 Industrial Acoustic Imager is a powerful tool designed to help you quickly and accurately detect and locate sound leaks, particularly in compressed air systems. With its advanced features and intuitive design, the ii900 makes it easy to identify potential problems and improve energy efficiency.

Key Features:

  • SoundMap™ Technology: Converts sound waves into visual images, allowing you to see sound leaks and other acoustic anomalies.
  • LeakQ™ Mode: Quantifies leak severity, providing estimates of leak size and potential cost savings.
  • Large Touchscreen Display: The 7-inch LCD touchscreen offers a clear and detailed view of the acoustic image.
  • Rugged Design: Built to withstand tough industrial environments, ensuring durability and reliability.
  • Intuitive Interface: Easy-to-use controls and menus make it simple to operate, even for beginners.
  • Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.

Applications:

  • Industrial Maintenance: Detect leaks in compressed air, gas, and steam systems.
  • HVAC: Identify air leaks and optimize system performance.
  • Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
  • Quality Control: Monitor product quality and identify noise sources.

By visualizing sound, the Fluke ii900 helps you save energy, reduce costs, and improve overall operational efficiency. Its advanced features and intuitive design make it a valuable tool for professionals in various industries.

Additional information

Brand

Fluke

Specifications: Fluke ii900 Industrial Acoustic Imager

Sensors
# of microphones 64 digital MEMS microphones
Frequency band 2 kHz to 52 kHz
Sound pressure sensitivity Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet
(Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters)
Operation distance range 0.5 to > 70 meters (1.6 to > 164 feet)*
Field of View 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions

 

Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °
Focus Fixed lens
Zoom 3 x Digital Zoom
Resolution 1.2 MP

 

Display 7″ LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic Image Yes, SoundMap™ image

 

Image storage
Storage capacity 20GB (>5000 pictures / >999 videos)
Image format Blended visual and SoundMap™.JPG or .PNG
Video format Blended visual and SoundMap™.MP4
Video length Up to 5 minutes
Digital export USB-C for data transfer

 

Acoustic Measurements
Sound pressure (typical) 15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz
5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz
28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz
41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry
Classification and quantification LeakQ™
Leak size and cost estimation

 

Software
Ease of use Intuitive user interface
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image
Asset ID QR code based asset ID identification
Asset Inspection Status: ‘As left’, ‘As found’ ; ‘Undetermined’
Photo notes Up to 4 photos notes for reference
Source Show single or multiple sources
Profile Preset capture profiles
Annotation: Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure;
Other Operating conditions; Weather notes
Leak values Leak costs; Leak volume; LeakQ™ scale

 

Battery
Batteries (field-replaceable, rechargeable) Rechargeable Li-ion
Battery life 6 hours (product includes spare battery)
Battery charging time 3 hours
Battery charging system External charger

 

General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red
Operating Temperature -10 °C to 45 °C (14 °F to 113 °F)
Storage Temperature -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity 10 % to 95 % non-condensing
Size (H x W x L) 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included) 1.8 kg (3.95 pounds)
Ingress Protection (IP) IP40
Fluke Premium Care Premium Care Standard**
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliant Yes
** Subject to regional availability

 

Safety
General Safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

 

Models: Fluke ii900 Industrial Acoustic Imager
Includes:

  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

Related Products