Fluke ii900 Industrial Acoustic Imager
- SoundMap™ Technology: Converts sound waves into visual images.
- LeakQ™ Mode: Quantifies leak severity.
- Large Touchscreen Display: Clear and detailed view of the acoustic image.
- Rugged Design: Durable and reliable for tough conditions.
- Intuitive Interface: Easy-to-use controls and menus.
- Fluke Connect Compatibility: Remote sharing and analysis of data.
- High-Resolution Sensor: Captures detailed acoustic images.
- Wide Frequency Range: Detects a broad range of sound frequencies.
- Adjustable Sensitivity: Customize detection sensitivity to specific needs.
- Image and Video Recording: Capture and save images and videos for documentation.
- Description
- Additional information
- Specifications
- Models
Description
The Fluke ii900 Industrial Acoustic Imager is a powerful tool designed to help you quickly and accurately detect and locate sound leaks, particularly in compressed air systems. With its advanced features and intuitive design, the ii900 makes it easy to identify potential problems and improve energy efficiency.
Key Features:
- SoundMap™ Technology: Converts sound waves into visual images, allowing you to see sound leaks and other acoustic anomalies.
- LeakQ™ Mode: Quantifies leak severity, providing estimates of leak size and potential cost savings.
- Large Touchscreen Display: The 7-inch LCD touchscreen offers a clear and detailed view of the acoustic image.
- Rugged Design: Built to withstand tough industrial environments, ensuring durability and reliability.
- Intuitive Interface: Easy-to-use controls and menus make it simple to operate, even for beginners.
- Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.
Applications:
- Industrial Maintenance: Detect leaks in compressed air, gas, and steam systems.
- HVAC: Identify air leaks and optimize system performance.
- Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
- Quality Control: Monitor product quality and identify noise sources.
By visualizing sound, the Fluke ii900 helps you save energy, reduce costs, and improve overall operational efficiency. Its advanced features and intuitive design make it a valuable tool for professionals in various industries.
Additional information
Brand | Fluke |
---|
Specifications: Fluke ii900 Industrial Acoustic Imager
Sensors | |
# of microphones | 64 digital MEMS microphones |
Frequency band | 2 kHz to 52 kHz |
Sound pressure sensitivity | Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet (Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters) |
Operation distance range | 0.5 to > 70 meters (1.6 to > 164 feet)* |
Field of View | 63 ° ± 5 ° |
Nominal frame rate | 25 FPS |
*Depending on ambient conditions |
Built-in digital camera (visible light) | |
Field of View (FOV) | 63 ° ± 5 ° |
Focus | Fixed lens |
Zoom | 3 x Digital Zoom |
Resolution | 1.2 MP |
Display | 7″ LCD with backlight, under-sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic Image | Yes, SoundMap™ image |
Image storage | |
Storage capacity | 20GB (>5000 pictures / >999 videos) |
Image format | Blended visual and SoundMap™.JPG or .PNG |
Video format | Blended visual and SoundMap™.MP4 |
Video length | Up to 5 minutes |
Digital export | USB-C for data transfer |
Acoustic Measurements | |
Sound pressure (typical) | 15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz 5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz 28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz 41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz |
Auto max/min dB gain | Auto or manual, user selectable |
Frequency band selection | User selectable through user-made presets or manual entry |
Classification and quantification | LeakQ™ Leak size and cost estimation |
Software | |
Ease of use | Intuitive user interface |
Trend graphs | Frequency and dB scale |
Spot markers | dB level reading at center point of the image |
Asset ID | QR code based asset ID identification |
Asset Inspection Status: | ‘As left’, ‘As found’ ; ‘Undetermined’ |
Photo notes | Up to 4 photos notes for reference |
Source | Show single or multiple sources |
Profile | Preset capture profiles |
Annotation: | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure; |
Other | Operating conditions; Weather notes |
Leak values | Leak costs; Leak volume; LeakQ™ scale |
Battery | |
Batteries (field-replaceable, rechargeable) | Rechargeable Li-ion |
Battery life | 6 hours (product includes spare battery) |
Battery charging time | 3 hours |
Battery charging system | External charger |
General Specifications | |
Standard palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating Temperature | -10 °C to 45 °C (14 °F to 113 °F) |
Storage Temperature | -20 °C to 70 °C (-4 °F to 158 °F) Without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
Weight (battery included) | 1.8 kg (3.95 pounds) |
Ingress Protection (IP) | IP40 |
Fluke Premium Care | Premium Care Standard** |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
** Subject to regional availability |
Safety | |
General Safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Models: Fluke ii900 Industrial Acoustic Imager
Includes:
- Imager
- AC power supply and battery pack charger (including universal AC adapters)
- Two rugged lithium ion smart battery packs
- USB cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap