Fluke ii500 Acoustic Imager
- SoundMap™ Technology: Converts sound waves into visual images.
- Intuitive Interface: Easy-to-use touchscreen interface.
- LeakQ™ Mode: Quantifies leak severity.
- Rugged Design: Durable and reliable for tough conditions.
- Long Battery Life: Extended usage without frequent recharging.
- Fluke Connect Compatibility: Remote sharing and analysis of data.
- High-Resolution Display: Clear and detailed images.
- Wide Frequency Range: Detects a broad range of sound frequencies.
- Adjustable Sensitivity: Customize detection sensitivity to specific needs.
- Image and Video Recording: Capture and save images and videos for documentation.
- Description
- Additional information
- Specifications
- Models
Description
The Fluke ii500 Acoustic Imager is a powerful tool that allows you to visualize sound waves, making it easy to detect and locate sound sources, such as leaks in compressed air systems, gas leaks, and mechanical issues.
Key Features:
- SoundMap™ Technology: This innovative technology converts sound waves into visual images, allowing you to see sound leaks and other acoustic anomalies.
- Intuitive Interface: The large, high-resolution touchscreen and simple controls make the ii500 easy to use, even for those with minimal training.
- LeakQ™ Mode: Quickly estimate the size and cost of leaks, helping you prioritize repairs.
- Rugged Design: Built to withstand tough conditions, the ii500 is durable and reliable.
- Long Battery Life: Enjoy extended use without frequent recharging.
- Fluke Connect Compatibility: Share and analyze data remotely with the Fluke Connect app and software.
Applications:
- Industrial Maintenance: Detect leaks in compressed air, gas, and steam systems.
- HVAC: Identify air leaks and optimize system performance.
- Mechanical Maintenance: Diagnose bearing failures and other mechanical issues.
- Quality Control: Monitor product quality and identify noise sources.
The Fluke ii500 is a versatile and powerful tool that can help you improve efficiency, reduce costs, and enhance safety. By visualizing sound, you can quickly identify and address potential problems before they escalate.
Additional information
Brand | Fluke |
---|
Specifications: Fluke ii500 Acoustic Imager
Specifications | |
Key Features | ii500 |
Sensors | |
Frequency band | 2 kHz to 52 kHz |
Detection range1 | 0.5 to > 50 meters (1.6 to > 164 feet) |
Field of view (FOV) | 63°± 5° |
Nominal frame rate | 25 FPS |
Built-in digital camera (visible light) | |
Field of view (FOV) | 63°± 5° |
Focus | Fixed lens |
Zoom | No zoom |
Resolution | 0.3 MP |
Display | |
Size | 7″ LCD with backlight, sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic image | SoundMapTM image |
Image storage | |
Storage capacity | 20 GB (> 5,000 pictures / > 999 videos) |
Image format | Blended visual and SoundMapTM .JPG or .PNG |
Video format | Blended visual and SoundMapTM .MP4 |
Video length | Up to 5 minutes |
Digital export | USB-C for data transfer |
Acoustic measurements | |
Measurement range (typical) | 15.4 to 115.2 dB SPL (± 1 dB SPL 2 kHz) 5.6 to 102.5 dB SPL (± 2 dB SPL 19 kHz) 28.4 to 131.1 dB SPL (± 1 dB SPL 35 kHz) 41.8 to 133.1 dB SPL (± 3 dB SPL 52 kHz) |
Classification and quantification | |
LeakQTM | Leak size scale (1-10) |
PDQ ModeTM | – |
MecQTM | – |
Auto max/min dB gain | Auto |
Frequency band selection | User selectable through user-made presets or manual entry |
Battery | |
Battery | Rechargeable and field replaceable Li-ion battery |
Battery life | 6 hours |
Battery charging time | 3 hours |
Battery charging system | External (Bay charger) |
Software | |
Ease of use | Intuitive user interface |
Acoustics: Show dB scale | On/Off |
Acoustics: Min/Max dB | Manual/Auto |
Acoustics: Profiles | – |
Acoustics: High frequency | – |
Acoustics: Multiple sources | Single source |
Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red |
Palette: Overly transparency | Yes: 1-100 % |
Grayscale mode | Yes |
Centerpoint markers | On/Off |
Trend graphs | Frequency and dB scale |
Spotmarkers | dB level reading at center point of image |
Leak values | LeakQTM scale (1-10) |
Master admin menu | – |
Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
Photo notes | Up to 4 photos notes for reference |
Asset inspection status | – |
Asset ID | Text input and automatic QR code based asset ID identification |
Actions annotation | – |
Other | – |
General specifications | |
Tripod holder / connector | – |
USB | 1 x USB-C |
Wireless | – |
Operating Temperature | -10 to 45 °C (14 to 113 °F) |
Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed |
Relative humidity | 10 to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
Weight (battery included) | 2.1 kg (4.6 pounds) |
Ingress Protection (IP) | IP40 |
Fluke Premium Care | Premium Care Standard2 |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
Safety | |
General safety | IEC 61010-1: Pollution degree 2 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
Models: Fluke ii500 Acoustic Imager
Includes:
- Fluke ii500 Acoustic Imager
- AC power supply and battery pack charger (including universal AC adapters)
- Rugged lithium-ion smart battery pack
- USB cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap
- Sensor array protection cover