Fluke 787B ProcessMeter

  • Compact digital multimeter and mA loop calibrator solution
  • Measure/Source/Simulate loop currents while powering the loop
  • Manual and automatic ramp up – ramp down functions
  • Easy-to-read backlit display

Description

The Fluke 787B ProcessMeter is a versatile and powerful tool that combines the functionality of a high-performance digital multimeter (DMM) with a 4-20 mA loop calibrator in a single, compact unit.

Key Features:

  • Versatile Measurement Capabilities:
    • DMM Functions: Measures voltage (AC/DC), current (AC/DC), resistance, frequency, capacitance, and more, providing comprehensive electrical measurement capabilities.
    • mA Loop Calibration: Sources and measures 4-20 mA signals, allowing for accurate calibration and troubleshooting of process loops.
  • Enhanced Functionality:
    • Simultaneous mA and % of Scale Readout: Displays both mA and percent of scale readings simultaneously, simplifying loop calibration and troubleshooting.
    • Loop Power Supply: Provides loop power to transmitters, eliminating the need for a separate power supply.
  • Rugged and Durable: Designed to withstand harsh industrial environments and provide reliable performance in demanding conditions.
  • User-Friendly Interface: Intuitive controls and a clear display make it easy to operate and interpret measurements.

Applications:

  • Process Instrumentation: Calibration and troubleshooting of process transmitters, sensors, and control loops in industrial plants.
  • Electrical Troubleshooting: Diagnosing electrical problems in industrial equipment and systems.
  • Maintenance and Repair: Identifying and resolving electrical and instrumentation issues during equipment maintenance.
  • Predictive Maintenance: Monitoring the health of process equipment and identifying potential problems before they lead to costly downtime.

The Fluke 787B is a valuable asset for industrial technicians and engineers. Its combination of DMM functionality, advanced loop calibration capabilities, and rugged design makes it a powerful tool for improving process efficiency, reducing downtime, and ensuring the reliable operation of industrial processes.

Additional information

Brand

Fluke Calibration

Specifications: Fluke 787B ProcessMeterâ„¢

Measurement function Range and resolution Best accuracy (% of reading + LSD)
V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1% + 1
V ac (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7% + 2
mA dc 30.000 mA .05% + 2
A dc 1.000 A (0.440 A continuous) 0.2% + 2
A ac 1.000 A (0.440 A continuous) 1% + 2
Resistance 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 0.2% + 1
Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz .005% + 1
Diode test 2.000 V (shows diode voltage drop) 2% + 1
Continuity Beeps for resistance < approx. 100 ohms
Output function Range and resolution Drive capability Accuracy (% of span)
DC current output (Internal battery operation) 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA 24 V compliance or, 1,200 ohms, @ 20 mA 0.05%
DC current simulate (Ext. 15 V to 48 V loop supply) 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA 1000 ohms, @ 20 mA 0.05%
Current adjustment modes Manual: Coarse, Fine, 25% and 100% step
Automatic: Slow Ramp, Fast Ramp, 25% step
Temperature range of 18 °C to 28 °C, for one year after calibration
General specifications
Maximum voltage applied between any jack and earth ground 1000 V RMS
Storage temperature -40 °C to 60 °C
Operating temperature -20 °C to 55 °C
Temperature coefficient 0.05 x (specified accuracy) per °C (for temperatures < 18 °C or > 28 °C)
Relative humidity 95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C
Vibration Random, 2 g, 5-500 Hz
Shock 1 meter drop test
Safety IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V
Size (HxWxL) 50 x 100 x 203 mm (1.97 x 3.94 x 8.00 in)
Weight 600 g (1.3 lbs)
Battery Four AA alkaline batteries
Battery life 140 hours typical (measurement), 10 hours typical (sourcing 12 mA)

 