Fluke 725Ex Series Process Calibrator

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

Description

The Fluke 725Ex is an intrinsically safe, multifunction process calibrator designed for use in hazardous areas where explosive gases may be present. It’s a versatile tool that can measure and source various electrical signals, as well as measure pressure with optional pressure modules.

Key Features:

  • Intrinsic Safety:
    • Primary Key Feature: Meets stringent safety standards (Class I, Division 1, Groups B, C, and D) to prevent ignition in explosive atmospheres.
  • Multifunctionality:
    • Measures and sources a broad range of electrical signals: DC voltage, DC current, resistance, frequency, and temperature (RTDs and thermocouples).
    • Expands capabilities with optional pressure modules for comprehensive pressure measurements.
  • Two-Channel Operation:
    • Enables simultaneous source and measure functions, streamlining transmitter calibration.
  • Rugged Construction:
    • Built to withstand harsh field conditions with a durable design and protective rubber boot.
  • User-Friendly Interface:
    • Intuitive controls and a clear display simplify operation, even in challenging environments.
  • Pressure Measurement:
    • Compatible with a range of Fluke-700PEx pressure modules for accurate pressure measurements up to 3,000 psi/200 bar.
  • Loop Power:
    • Provides 24V loop power for powering transmitters during calibration.
  • Communication:
    • Optional HART communication capabilities for interacting with HART-enabled devices.

Applications:

  • Oil and Gas: Calibrating instruments in refineries, offshore platforms, and other hazardous locations in the oil and gas industry.
  • Chemical Processing: Calibrating process instruments in chemical plants and other hazardous industrial environments.
  • Pharmaceutical Manufacturing: Calibrating equipment in pharmaceutical production facilities.
  • Other Hazardous Industries: Used in any industry where there is a risk of explosive atmospheres, such as mining, petrochemical, and food processing.

By combining safety, versatility, and accuracy, the Fluke 725Ex is a valuable tool for technicians and engineers working in hazardous environments.

Additional information

Brand

Fluke Calibration

Specifications: Fluke 725Ex Series Process Calibrator

Measurement Accuracy
Voltage DC 30.000 V 0.02% + 2 counts (upper display)
10.000 V 0.02% + 2 counts (lower display)
90.00 mV 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency 2.0 to 1000.0 CPM 0.05% + 1 count
1.0 to 1100.0 Hz 0.05% + 1 count
1.00 to 10.00 kHz 0.05% + 1 count
Sensitivity 1 V peak-to-peak-minimum
Pressure Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC 100.00 mV 0.02% + 2 counts
10.000 V 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (source) 0.02% + 2 counts
24.000 mA (simulate) 0.02% + 2 counts
Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency 2.0 to 1000.0 CPM 0.05%
1.0 to 1100.0 Hz 0.05%
1.00 to 10.00 kHz 0.25%
Waveform 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.8°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK 0.6°C
BP 1.2°C
Source accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
Accuracy stated for 4-wire measurement.
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.4°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK 0.6°C
BP 1.2°C
Specifications
Ramp functions Source functions Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp
Loop power function Voltage 12 V
Accuracy 10%
Maximum current 22 mA, short circuit protected
Step functions Source functions Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range
Safety specifications
Agency approvals I.S. Class I, Division 1 Groups B-D
Mechanical and General Specifications
Size 130 x 236 x 61 mm (5.188 x 9.291 x 2.402 in)
Weight 0.85 kg (1.874 lbs.)
Batteries 4 AA alkaline batteries
Warranty Three year
Battery replacement Separate battery compartment, accessible without breaking calibration seal
Side port connections Pressure module connector

 