Fluke 725Ex Series Process Calibrator
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
- Description
- Additional information
- Specifications
Description
The Fluke 725Ex is an intrinsically safe, multifunction process calibrator designed for use in hazardous areas where explosive gases may be present. It’s a versatile tool that can measure and source various electrical signals, as well as measure pressure with optional pressure modules.
Key Features:
- Intrinsic Safety:
- Primary Key Feature: Meets stringent safety standards (Class I, Division 1, Groups B, C, and D) to prevent ignition in explosive atmospheres.
- Multifunctionality:
- Measures and sources a broad range of electrical signals: DC voltage, DC current, resistance, frequency, and temperature (RTDs and thermocouples).
- Expands capabilities with optional pressure modules for comprehensive pressure measurements.
- Two-Channel Operation:
- Enables simultaneous source and measure functions, streamlining transmitter calibration.
- Rugged Construction:
- Built to withstand harsh field conditions with a durable design and protective rubber boot.
- User-Friendly Interface:
- Intuitive controls and a clear display simplify operation, even in challenging environments.
- Pressure Measurement:
- Compatible with a range of Fluke-700PEx pressure modules for accurate pressure measurements up to 3,000 psi/200 bar.
- Loop Power:
- Provides 24V loop power for powering transmitters during calibration.
- Communication:
- Optional HART communication capabilities for interacting with HART-enabled devices.
Applications:
- Oil and Gas: Calibrating instruments in refineries, offshore platforms, and other hazardous locations in the oil and gas industry.
- Chemical Processing: Calibrating process instruments in chemical plants and other hazardous industrial environments.
- Pharmaceutical Manufacturing: Calibrating equipment in pharmaceutical production facilities.
- Other Hazardous Industries: Used in any industry where there is a risk of explosive atmospheres, such as mining, petrochemical, and food processing.
By combining safety, versatility, and accuracy, the Fluke 725Ex is a valuable tool for technicians and engineers working in hazardous environments.
Additional information
Brand | Fluke Calibration |
---|
Specifications: Fluke 725Ex Series Process Calibrator
Measurement Accuracy | ||
Voltage DC | 30.000 V | 0.02% + 2 counts (upper display) |
10.000 V | 0.02% + 2 counts (lower display) | |
90.00 mV | 0.02% + 2 counts | |
-10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
Current DC | 24.000 mA | 0.02% + 2 counts |
Resistance | 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) | |
1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% + 1 count |
1.0 to 1100.0 Hz | 0.05% + 1 count | |
1.00 to 10.00 kHz | 0.05% + 1 count | |
Sensitivity | 1 V peak-to-peak-minimum | |
Pressure | Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. | |
Source Accuracy | ||
Voltage DC | 100.00 mV | 0.02% + 2 counts |
10.000 V | 0.02% + 2 counts | |
-10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
Current DC | 24.000 mA (source) | 0.02% + 2 counts |
24.000 mA (simulate) | 0.02% + 2 counts | |
Resistance | 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
401 to 1500 Ω | 0.5 Ω (excitation current 0.05 to 0.8 mA) | |
1500 to 3200 Ω | 1 Ω (excitation current 0.05 to 0.4 mA) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% |
1.0 to 1100.0 Hz | 0.05% | |
1.00 to 10.00 kHz | 0.25% | |
Waveform | 5 V p-p squarewave, -0.1 V offset | |
RTDs and Thermocouples | ||
Measure accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.8°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
XK | 0.6°C | |
BP | 1.2°C | |
Source accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
Accuracy stated for 4-wire measurement. | ||
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.4°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C | |
XK | 0.6°C | |
BP | 1.2°C | |
Specifications | ||
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
Loop power function | Voltage | 12 V |
Accuracy | 10% | |
Maximum current | 22 mA, short circuit protected | |
Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
Steps | 25% of range, 100% of range | |
Safety specifications | ||
Agency approvals | I.S. Class I, Division 1 Groups B-D | |
Mechanical and General Specifications | ||
Size | 130 x 236 x 61 mm (5.188 x 9.291 x 2.402 in) | |
Weight | 0.85 kg (1.874 lbs.) | |
Batteries | 4 AA alkaline batteries | |
Warranty | Three year | |
Battery replacement | Separate battery compartment, accessible without breaking calibration seal | |
Side port connections | Pressure module connector |