Fluke 718Ex Intrinsically Safe Pressure Calibrator

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.

Description

The Fluke 718Ex is an intrinsically safe, handheld pressure calibrator designed for use in hazardous areas.

Key Features:

  • Enhanced Safety:
    • Primary Benefit: Its intrinsic safety certification allows for safe operation in explosive atmospheres, minimizing the risk of accidents and ensuring worker safety.
  • Increased Efficiency:
    • Built-in Hand Pump: Eliminates the need for external air sources, streamlining the calibration process and improving efficiency in the field.
  • Improved Accuracy:
    • High accuracy (0.05%) ensures reliable and precise pressure measurements, leading to more accurate instrument calibrations and improved process control.
  • Enhanced Portability:
    • Compact and lightweight design facilitates easy transportation and maneuverability in confined spaces, making it ideal for field service and maintenance applications.
  • User-Friendly Operation:
    • Intuitive controls and a clear display simplify operation, even for less experienced technicians.
  • Rugged Durability:
    • Robust construction withstands harsh environmental conditions and accidental drops, ensuring long-term reliability and reducing the risk of equipment damage.

Applications:

  • Process Control: Calibrating pressure transmitters, sensors, and gauges in various industrial processes.
  • Field Service and Maintenance: On-site calibration and troubleshooting of pressure instruments in hazardous locations.
  • Oil and Gas: Calibrating pressure instruments in refineries, offshore platforms, and other hazardous locations in the oil and gas industry.

By combining portability, accuracy, and intrinsic safety, the Fluke 718Ex is a valuable tool for technicians and engineers working in hazardous environments who require reliable pressure measurements and calibrations.

Additional information

Brand

Fluke Calibration

Specifications: Fluke 718Ex Intrinsically Safe Pressure Calibrator

Pressure Measurement Accuracy
Fluke 718Ex 30G Range -830 mbar to 2 bar (internal sensor)
Over pressure: 3x FS
Resolution 0.0001 bar
Accuracy 0.05% FS
Functions Zero, Min, Max, Hold, Damp
Fluke 718Ex 100G Range -830 mbar to 2 bar (internal sensor)
Over pressure: 2x FS
Resolution 0.001 bar
Accuracy 0.05% FS
Functions Zero, Min, Max, Hold, Damp
Fluke 718Ex 300G Range -830 mbar to 20 bar (internal sensor)
Over pressure: 375 psi, 25 bar
Resolution 0.0001 bar
Accuracy 0.05% FS
Functions Zero, Min, Max, Hold, Damp
Fluke 718Ex series Range Via pressure module connector
29 pressure modules, 2.5 mbar to 700 bar
Over pressure per pressure module specs
Resolution Per pressure module specs
Accuracy To 0.025% of full span, per pressure module specs
Functions Zero, Min, Max, Hold, Damp
Source pressure, built in pump range -820 mbar to full scale
For use with non-corrosive gasses.
Supported Pressure Units psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm², mmHg, inHg
Media compatibility per pressure module specs
Technical Data
Measure accuracy Range 0-24 mA
Resolution 0.001 mA
Accuracy 0.02% rdg ±2 counts
Display LCD, 5 digit pressure and current simultaneous
Environmental Specifications
Operating temperature -10°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 95% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
35% (50°C to 55°C)
Operating altitude 3,000 m max
Safety Specifications
Safety ATEX II 1G Ex ia IIC T4 compliant
CSA Certification I.S. Class I
Div 1 Groups A-D , T4
Mechanical and General Specifications
Size (L x W x H) 216 x 94 x 66 mm (with holster)
Weight Approx. 992 g (with holster)
Warranty Three years, one year for pump
Shock 1 meter drop test
Vibration Random, 2 G, 5-500 Hz
Battery type One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
Battery life 4 to 20 hours, depending on functions used

 