Fluke 718Ex Intrinsically Safe Pressure Calibrator
- ATEX II 1G Ex ia IIC T4 Compliant.
- Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
- Wide range of selectable measurement units for pressure.
- Current measurement with 0.02% accuracy and 0.001 mA resolution.
- Pressure switch test function.
- Min-Max Hold functions.
- Compact size and weight.
- Simple, push-button user interface.
- Rugged and reliable, ideal for field use.
- Description
- Additional information
- Specifications
Description
The Fluke 718Ex is an intrinsically safe, handheld pressure calibrator designed for use in hazardous areas.
Key Features:
- Enhanced Safety:
- Primary Benefit: Its intrinsic safety certification allows for safe operation in explosive atmospheres, minimizing the risk of accidents and ensuring worker safety.
- Increased Efficiency:
- Built-in Hand Pump: Eliminates the need for external air sources, streamlining the calibration process and improving efficiency in the field.
- Improved Accuracy:
- High accuracy (0.05%) ensures reliable and precise pressure measurements, leading to more accurate instrument calibrations and improved process control.
- Enhanced Portability:
- Compact and lightweight design facilitates easy transportation and maneuverability in confined spaces, making it ideal for field service and maintenance applications.
- User-Friendly Operation:
- Intuitive controls and a clear display simplify operation, even for less experienced technicians.
- Rugged Durability:
- Robust construction withstands harsh environmental conditions and accidental drops, ensuring long-term reliability and reducing the risk of equipment damage.
Applications:
- Process Control: Calibrating pressure transmitters, sensors, and gauges in various industrial processes.
- Field Service and Maintenance: On-site calibration and troubleshooting of pressure instruments in hazardous locations.
- Oil and Gas: Calibrating pressure instruments in refineries, offshore platforms, and other hazardous locations in the oil and gas industry.
By combining portability, accuracy, and intrinsic safety, the Fluke 718Ex is a valuable tool for technicians and engineers working in hazardous environments who require reliable pressure measurements and calibrations.
Additional information
| Brand | Fluke Calibration |
|---|
Specifications: Fluke 718Ex Intrinsically Safe Pressure Calibrator
| Pressure Measurement Accuracy | ||
| Fluke 718Ex 30G | Range | -830 mbar to 2 bar (internal sensor) Over pressure: 3x FS |
| Resolution | 0.0001 bar | |
| Accuracy | 0.05% FS | |
| Functions | Zero, Min, Max, Hold, Damp | |
| Fluke 718Ex 100G | Range | -830 mbar to 2 bar (internal sensor) Over pressure: 2x FS |
| Resolution | 0.001 bar | |
| Accuracy | 0.05% FS | |
| Functions | Zero, Min, Max, Hold, Damp | |
| Fluke 718Ex 300G | Range | -830 mbar to 20 bar (internal sensor) Over pressure: 375 psi, 25 bar |
| Resolution | 0.0001 bar | |
| Accuracy | 0.05% FS | |
| Functions | Zero, Min, Max, Hold, Damp | |
| Fluke 718Ex series | Range | Via pressure module connector 29 pressure modules, 2.5 mbar to 700 bar Over pressure per pressure module specs |
| Resolution | Per pressure module specs | |
| Accuracy | To 0.025% of full span, per pressure module specs | |
| Functions | Zero, Min, Max, Hold, Damp | |
| Source pressure, built in pump range | -820 mbar to full scale | |
| For use with non-corrosive gasses. Supported Pressure Units psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm², mmHg, inHg Media compatibility per pressure module specs |
||
| Technical Data | ||
| Measure accuracy | Range | 0-24 mA |
| Resolution | 0.001 mA | |
| Accuracy | 0.02% rdg ±2 counts | |
| Display | LCD, 5 digit pressure and current simultaneous | |
| Environmental Specifications | ||
| Operating temperature | -10°C to 55°C | |
| Storage temperature | -40°C to 60°C | |
| Humidity (without condensation) | 95% (10°C to 30°C) | |
| 75% (30°C to 40°C) | ||
| 45% (40°C to 50°C) | ||
| 35% (50°C to 55°C) | ||
| Operating altitude | 3,000 m max | |
| Safety Specifications | ||
| Safety | ATEX II 1G Ex ia IIC T4 compliant | |
| CSA Certification I.S. Class I | ||
| Div 1 Groups A-D , T4 | ||
| Mechanical and General Specifications | ||
| Size (L x W x H) | 216 x 94 x 66 mm (with holster) | |
| Weight | Approx. 992 g (with holster) | |
| Warranty | Three years, one year for pump | |
| Shock | 1 meter drop test | |
| Vibration | Random, 2 G, 5-500 Hz | |
| Battery type | One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V | |
| Battery life | 4 to 20 hours, depending on functions used | |