Fluke 718 Pressure Calibrator
- Pressure Source and mA Measurement to calibrate pressure devices
- Built-in pump for sourcing pressure to 300 PSI
- Easy-to-clean, field-serviceable, integrated pressure pump
- Built-in switch test for calibrating pressure switches
- Extend pressure capabilities by using Fluke 750P pressure modules
- Description
- Additional information
- Specifications
Description
The Fluke 718 Pressure Calibrator is a compact and versatile tool designed for efficient and accurate pressure calibration. This handheld device combines pressure generation and measurement capabilities, making it a valuable asset for technicians and engineers in various industries.
Key Features:
- Accurate Pressure Generation: The 718 can generate precise pressure levels, allowing for thorough testing and calibration of pressure transmitters, switches, and gauges.
- Pressure Measurement: The built-in pressure sensor provides accurate measurements, enabling verification of instrument readings and comparison against generated pressures.
- Compact and Portable: The 718’s compact size and lightweight design make it easy to carry and use in the field.
- Rugged and Durable: Built to withstand harsh industrial environments, the 718 is designed for reliable performance in demanding conditions.
The Fluke 718 is widely used in various industries, including:
- Process Control: Calibrating pressure transmitters, switches, and gauges used in process control systems to ensure optimal plant operation and efficiency.
- Oil and Gas: Calibrating pressure instrumentation in oil and gas production and transportation, maximizing safety and productivity.
- Chemical Processing: Calibrating pressure instruments in chemical plants and refineries for optimal process control and safety.
By providing accurate and efficient pressure calibration, the Fluke 718 helps ensure the safe and reliable operation of critical equipment and processes across a wide range of industries.
Additional information
Brand | Fluke Calibration |
---|
Specifications: Fluke 718 Pressure Calibrator
Technical Specifications | |
Fluke 718 Series | |
Measure pressure | (Internal sensor) |
Accuracy | 0.025% full scale |
Functions | Zero, min/max, hold, damp |
Dry air, non-corrosives only | |
Fluke 718 1G | |
Range | -1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa) |
Resolution | 0.0001 psi, 0.001 mbar, 0.0001 kPa |
Over pressure | 5x Full Scale |
Functions | Zero, Min, Max, Hold, Damp |
Fluke 718 30G | |
Range | -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa) |
Resolution | 0.001 psi, 0.1 mbar, 0.01 kPa |
Over pressure | 5x Full Scale |
Functions | Zero, Min, Max, Hold, Damp |
Fluke 718 100G | |
Range | -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa) |
Resolution | 0.01 psi, 0.1 mbar, 0.01 kPa |
Over pressure | 2x Full Scale |
Functions | Zero, Min, Max, Hold, Damp |
Fluke 718 300G | |
Range | -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa) |
Resolution | 0.01 psi, 1 mbar, 0.1 kPa |
Over pressure | 375 psi 25 bar |
Functions | Zero, Min, Max, Hold, Damp |
Fluke 718 series via 700 Series Pressure Modules | |
Range | 29 pressure modules, 0 – 1 inH20 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs |
Resolution | Per pressure module specs |
Accuracy | To 0.025% of full span, per pressure module specs |
Functions | Zero, Min, Max, Hold, Damp |
Media compatibility per pressure module specs | |
Fluke 718 Series Via Built in Pump | |
Range | -12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH20 (4°C), inH20 (20°C), cmH20 (4°C), cmH20 (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm |
Loop power range | 24 V DC |
Accuracy | ±10% |
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V | |
mA Measure | |
Range | 0 mA to 24 mA |
Resolution | 0.001 mA |
Accuracy | 0.015% + 1 count |
General Specifications | |
Maximum voltage | 30 volts (non-operating) |
Temperature | -40°C to 60°C |
Operating temperature | -10°C to 55°C |
Relative humidity | 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C) |
Operating altitude | 3,000 M max |
Shock | 1 M drop test |
Vibration | Random, 2 g, 5 Hz – 500 Hz |
Safety | CSA C22.2 No. 1010.1: 1992 |
EMC | EN50082-1: 1992 and EN55022: 1994 Class B |
Size | 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in) |
Weight | 992 g (35 oz) |
Power, battery life | 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 |
Battery life | 4 to 20 hours typical, depending on functions used |
Warranty | Three years (one year on pressure pump in Fluke 718) |
Display | LCD, 5 digit pressure and current simultaneous |
For use with non-corrosive gasses |