Fluke 712B RTD Calibrators
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity checks
- Description
- Additional information
- Specifications
Description
The Fluke 712B is a specialized handheld calibrator designed for professionals working with RTD (Resistance Temperature Detectors) temperature sensors.
Key Features and Benefits:
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity checks
- RTD Focus: Specifically designed for measuring and simulating 13 different RTD types, making it ideal for calibrating a wide range of RTD-based temperature sensors.
- Resistance Measurement: Measures resistance directly, providing accurate readings for RTD calibration.
- 4-20 mA Signal Measurement: Allows simultaneous measurement of 4-20 mA signals while sourcing a temperature signal, facilitating comprehensive testing of process control loops.
- User-Friendly Interface: Intuitive design with easy-to-use controls and a clear display for efficient operation.
- Rugged and Portable: Built to withstand the demands of field environments, ensuring reliable performance in challenging conditions.
Applications:
- Calibration of RTD temperature sensors in various industries, including manufacturing, process control, and research.
- Testing and maintenance of RTD-based equipment.
- Process control optimization.
- Research and development.
In essence, the Fluke 712B is a valuable tool for professionals who require a dedicated and efficient solution for calibrating RTD temperature sensors.
Additional information
| Brand | Fluke Calibration |
|---|
Specifications: Fluke 712B RTD Calibrators
| General Specifications | |
| Maximum voltage applied between any terminal and earth ground or between any two terminals | 30 V |
| Operating temperature | -10°C to 50°C |
| Storage temperature | -30°C to 60°C |
| Operating altitude | 2,000 m |
| Storage altitude | 12,000 m |
| Relative humidity (% RH operating without condensation) | Non condensing |
| 90% (10°C to 30°C) | |
| 75% (30°C to 40°C) | |
| 45% (40°C to 50°C) | |
| (Without condensation) | |
| Vibration requirements | MIL-T-28800E, Class 2 |
| Drop text requirements | 1 m |
| IP Rating | IEC 60529: IP52 |
| Electromagnetic environment | IEC 61326-1, Portable |
| Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
| Power supply | 4 AA NEDA 1.5A IEC LR6 batteries |
| Size (H x W x L) | 52.5 x 84 x 188.5 mm |
| Weight | 515 g |
| DC mA Measurement | |
| Resolution | 0-24 mA |
| Range | 0.001 mA |
| Accuracy (% of reading + counts) | 0.010% + 2 μA |
| Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C) |
| Ohms Measurement | |
| Ohms range | Accuracy (% of reading +counts) |
| 0.00 Ω to 400.00 Ω | 0.015% + 0.05 Ω |
| 400.0 Ω to 4000.0 Ω | 0.015% + 0.5 Ω |
| Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications. | |
| Temperature coefficient | ±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C) |
| Ohms Source | ||
| Ohms range | 1.0 Ω to 400.0 Ω | |
| 1.00 Ω to 400.00 Ω | ||
| 400.0 Ω to 1500.0 Ω | ||
| 1500.0 Ω to 4000.0 Ω | ||
| Excitation current from measurement device | 0.1 mA to 0.5 mA | |
| 0.5 mA to 3 mA | ||
| 0.05 mA to 0.8 mA | ||
| 0.05 mA to 0.4 mA | ||
| Accuracy (% of reading + counts) | 0.015% + 0.1 Ω | |
| 0.015% + 0.05 Ω | ||
| 0.015% + 0.5 Ω | ||
| 0.015% + 0.5 Ω | ||
| Resolution | 0.00 Ω to 400.00 Ω | 0.01 Ω |
| 400.0 Ω to 4000.0 Ω | 0.1 Ω | |
| Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C) Supports pulsed transmitters and PLCs with pulse times as short as 5 ms |
|
| RTD Input and Output | ||||||
| RTD Type (α) | Range (°C) | Measure (°C) | Source (°C) | |||
| 1-year | 2-year | Source current | 1-year | 2-year | ||
| 10 Ω Pt (385) | -200 to 100°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
| 100 to 800°C | 1.8°C | 3.6°C | 1 mA | 1.8°C | 3.6°C | |
| 50 Ω Pt (385) | -200 to 100°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
| 100 to 800°C | 0.5°C | 0.8°C | 1 mA | 0.5°C | 0.8°C | |
| 100 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
| 100 to 800°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
| 200 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 500 μA | 0.2°C | 0.4°C |
| 100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
500 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
| 500 Ω Pt (385) | -200 to 100°C | 0.3°C | 0.6°C | 250 μA | 0.3°C | 0.6°C |
| 100 to 630°C | 0.015% +0.28°C |
0.03% +0.56°C |
250 μA | 0.015% +0.28°C |
0.03% +0.56°C |
|
| 1000 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
| 100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
250 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
| 100 Ω Pt (3916) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
| 100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
| 100 Ω Pt (3926) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
| 100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
| 10 Ω Cu (427) | -100 to 260°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
| 120 Ω Ni (672) | -80 to 260°C | 0.15°C | 0.3°C | 1 mA | 0.15°C | 0.3°C |
| 50 Ω Cu (427) | -180 to 200°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
| 100 Ω Cu (427) | -180 to 200°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
| YSI400 | 15 to 50°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
| 1. Sensor inaccuracies not included. 2. Resolution: 0.1°C. 3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications. 4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range). 5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source. 6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms. |
||||||
Related Products
- Dual-zone control
- Full HART field communicator
- Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
- Set point control by reference
- Self-calibration feature
- ISO 17025-accredited calibration w/data included
- Reference level performance in accuracy, stability and uniformity
- Quick to temperature
- Two-channel readout measures RTDs and TCs, and provides task documentation
- Full HART communicator (PC Option)
- Built in automatic annealing feature (ADT878-700 only)
- ISO 17025-accredited calibration w/data included
- Temperature control from 100°C to 1210°C
- Two models to choose from: Reference (ADT878) and Standard (ADT875)
- Display Accuracy of ±1.5°C (ADT878)
- 4 on-board measurement channels (PC option)
- Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
- ISO 17025-accredited calibration w/data included
- 1502A: accuracy up to ±0.006 °C.
- 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
- 1502A: covers –200°C to 962°C
- 1504: covers 0 to 100°C
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
- Supports four channels for PRTs, thermistors, and thermocouples, accommodating a variety of sensor types.
- Display eight user-selected data fields from any channel.
- Log up to 8,000 readings with date and time stamps for data tracking.
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
- Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
- Scan up to 10 channels per second, great for high-speed applications.
- Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
- Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.
- Highly accurate thermo hygrometer and humidity monitor.
- Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
- Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
- Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
- 5608: –200 °C to 500 °C (80 mm minimum immersion)
- 5609: –200 °C to 670 °C (100 mm minimum immersion)
- ± 0.01 short-term stability
- Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
- Dry-well reference with 90 ° bend
- Highly accurate, easy-to-use thermocouple temperature calibrator
- Measures and simulates 17 thermocouple types and millivolts
- Measures 4 to 20 mA signals while sourcing a temperature signal
- Comes with a magnetic hanger for convenient hands-free operation
- Features configurable source settings for quick linearity checks
- Precision multifunction, temp, frequency, voltage, and mA calibrator
- Calibrates thermocouples and RTD temperature instruments
- Stores up to eight calibration results in memory for analysis
- Built-in 24 V Loop Power Supply
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
- Accuracy to ±0.25°C and comes with an RS-232 interface.
- The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
- The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
- Features designed with user convenience and productivity in mind.
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
- Wide Temperature Range: Covers a broad temperature range from -95°C to 140°C, suitable for a wide variety of applications, including those requiring low-temperature calibration.
- Portability: Remains compact and portable, allowing for on-site calibrations at various locations.
- Constructed using metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s).
- Every ITS-90 fixed point available from argon to copper
- Plateaus last days (gallium for weeks and TPW for months).
- Accredited Cell Intercomaparisons available.