Fluke 705 Loop Calibrator

  • Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
  • Provides simultaneous mA and % readout for quick, easy interpretation of readings.
  • Delivers mA accuracy of 0.02%
  • Features push button 25% steps for fast, easy linearity checks

Description

The Fluke 705 is a compact and cost-effective loop calibrator designed specifically for calibrating and troubleshooting 4-20 mA current loops in industrial process control systems.

Here’s a more in-depth look:

Key Features:

  • Accurate 4-20 mA Measurement and Sourcing:
    • Precisely measures and simulates 4-20 mA current signals with high accuracy (0.02% of reading).
    • Enables accurate calibration of transmitters, ensuring reliable process measurements.
  • Simultaneous mA and % Readout:
    • Displays both the actual current value (mA) and the percentage of the 4-20 mA range simultaneously.
    • Facilitates quick and easy interpretation of readings and simplifies troubleshooting.
  • Push-Button 25% Steps:
    • Allows for rapid linearity checks of transmitters by quickly stepping through 25% increments of the 4-20 mA range.
    • Speeds up the calibration process and improves efficiency.
  • 24V Loop Power Supply:
    • Provides the necessary power to operate the devices under test within the 4-20 mA loop.
    • Eliminates the need for a separate power source during calibration.

Applications:

  • Calibration of 4-20 mA Transmitters:
    • Calibrates transmitters used for measuring temperature, pressure, flow, level, and other process variables.
  • Troubleshooting Process Control Loops:
    • Helps identify and diagnose problems within 4-20 mA loops, such as signal interruptions, faulty transmitters, or incorrect wiring.
  • Verification of Control Valve and Actuator Performance:
    • Assesses the proper functioning of control valves and actuators by verifying their response to 4-20 mA signals.
  • Maintenance and Repair of Industrial Equipment:
    • Plays a crucial role in maintaining the accuracy and reliability of industrial process equipment by ensuring proper calibration and function.

The Fluke 705 is a valuable tool for technicians, engineers, and maintenance personnel working in various industries, including:

  • Process Control
  • Manufacturing
  • Oil & Gas
  • Water & Wastewater
  • Power Generation

By providing a reliable and efficient means of calibrating and troubleshooting 4-20 mA loops, the Fluke 705 helps to maintain the accuracy, reliability, and safety of industrial processes.

Additional information

Brand

Fluke Calibration

Specifications: Fluke 705 Loop Calibrator

Specifications
Current measurement Range 0 to 24 mA
Resolution 0.001 mA
Accuracy 0.02% Rdg + 2 LSD
Current sourcing Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.025% Rdg + 2 LSD
Drive capability 1000 Ω @ 24 mA
Current simulation Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.025% Rdg + 2 LSD
Ext. loop voltage requirement 12-30 V
Loop power While measuring mA, 24 V
Voltage measurement Range 0 to 28 V DC
Resolution 1 mV
Accuracy 0.025% Rdg + 2 LSD
Environmental Specifications
Operating temperature -10°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C)
Temperature coefficient -10°C to 18°C, 28°C to 55°C, ±.005% of range per°C
Safety Specifications
Safety CSA C22.2 No. 1010.1:1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage 30 V
Mechanical and General Specifications
Size 152 x 70 x 41 mm
Weight 340 g
Batteries One 9 V battery
Shock and vibration per MIL-T-28800 for a Class 2 Instrument
Display current and % of span Yes
Auto step, auto ramp Yes
Span check Yes

 

Related Products