Fluke 705 Loop Calibrator
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
- Description
- Additional information
- Specifications
Description
The Fluke 705 is a compact and cost-effective loop calibrator designed specifically for calibrating and troubleshooting 4-20 mA current loops in industrial process control systems.
Here’s a more in-depth look:
Key Features:
- Accurate 4-20 mA Measurement and Sourcing:
- Precisely measures and simulates 4-20 mA current signals with high accuracy (0.02% of reading).
- Enables accurate calibration of transmitters, ensuring reliable process measurements.
- Simultaneous mA and % Readout:
- Displays both the actual current value (mA) and the percentage of the 4-20 mA range simultaneously.
- Facilitates quick and easy interpretation of readings and simplifies troubleshooting.
- Push-Button 25% Steps:
- Allows for rapid linearity checks of transmitters by quickly stepping through 25% increments of the 4-20 mA range.
- Speeds up the calibration process and improves efficiency.
- 24V Loop Power Supply:
- Provides the necessary power to operate the devices under test within the 4-20 mA loop.
- Eliminates the need for a separate power source during calibration.
Applications:
- Calibration of 4-20 mA Transmitters:
- Calibrates transmitters used for measuring temperature, pressure, flow, level, and other process variables.
- Troubleshooting Process Control Loops:
- Helps identify and diagnose problems within 4-20 mA loops, such as signal interruptions, faulty transmitters, or incorrect wiring.
- Verification of Control Valve and Actuator Performance:
- Assesses the proper functioning of control valves and actuators by verifying their response to 4-20 mA signals.
- Maintenance and Repair of Industrial Equipment:
- Plays a crucial role in maintaining the accuracy and reliability of industrial process equipment by ensuring proper calibration and function.
The Fluke 705 is a valuable tool for technicians, engineers, and maintenance personnel working in various industries, including:
- Process Control
- Manufacturing
- Oil & Gas
- Water & Wastewater
- Power Generation
By providing a reliable and efficient means of calibrating and troubleshooting 4-20 mA loops, the Fluke 705 helps to maintain the accuracy, reliability, and safety of industrial processes.
Additional information
Brand | Fluke Calibration |
---|
Specifications: Fluke 705 Loop Calibrator
Specifications | ||
Current measurement | Range | 0 to 24 mA |
Resolution | 0.001 mA | |
Accuracy | 0.02% Rdg + 2 LSD | |
Current sourcing | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.025% Rdg + 2 LSD | |
Drive capability | 1000 Ω @ 24 mA | |
Current simulation | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.025% Rdg + 2 LSD | |
Ext. loop voltage requirement | 12-30 V | |
Loop power | While measuring mA, 24 V | |
Voltage measurement | Range | 0 to 28 V DC |
Resolution | 1 mV | |
Accuracy | 0.025% Rdg + 2 LSD | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C) | |
Temperature coefficient | -10°C to 18°C, 28°C to 55°C, ±.005% of range per°C | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
EMC | EN50082-1:1992 and EN55022:1994 Class B | |
Maximum voltage | 30 V | |
Mechanical and General Specifications | ||
Size | 152 x 70 x 41 mm | |
Weight | 340 g | |
Batteries | One 9 V battery | |
Shock and vibration | per MIL-T-28800 for a Class 2 Instrument | |
Display current and % of span | Yes | |
Auto step, auto ramp | Yes | |
Span check | Yes |