Fluke 1663 Installation Multifunction Tester
Comprehensive Testing Capabilities:
- Voltage and frequency measurement
- Resistance measurement
- Continuity testing
- Earth resistance measurement
- Loop impedance testing
- RCD testing (including Type B RCDs)
- Insulation resistance testing
- Polarity testing
- Phase rotation testing
- Description
- Additional information
- Specifications
- Models
Description
The Fluke 1663 Multifunction Installation Tester is a powerful tool designed to streamline and enhance the efficiency of electrical installations. This versatile device offers a comprehensive suite of testing capabilities, ensuring the safety and compliance of electrical systems in various settings.
Key Features:
Comprehensive Testing Capabilities: The 1663 covers a wide range of essential tests, including:
- Voltage and frequency measurement
- Resistance measurement
- Continuity testing
- Earth resistance measurement
- Loop impedance testing
- RCD testing (including sensitive Type B RCDs)
- Insulation resistance testing
- Polarity testing
- Phase rotation testing
Applications:
- Electrical Installations: Verifying the safety and compliance of new installations.
- Periodic Inspections: Conducting routine inspections to identify potential hazards and ensure ongoing safety.
- Fault Finding: Diagnosing electrical faults and troubleshooting issues.
- Maintenance and Repair: Supporting maintenance and repair activities.
Benefits:
- Enhanced Safety: By ensuring the correct functioning of electrical systems, the 1663 helps prevent accidents and electrical shocks.
- Increased Efficiency: Automated tests and streamlined workflows improve productivity.
- Accurate and Reliable Results: Precise measurements and advanced features ensure accurate and reliable test results.
- Compliance with Standards: The 1663 helps users comply with relevant electrical safety standards and regulations.
Overall, the Fluke 1663 is a valuable tool for electrical professionals, providing a comprehensive solution for testing, troubleshooting, and maintaining electrical installations. Its advanced features, user-friendly interface, and robust design make it an essential tool for ensuring safety and efficiency in the electrical industry.
Additional information
Brand | Fluke |
---|
Specifications: Fluke 1663 Installation Multifunction Tester
Specifications: Fluke 1663 and 1664 FC Installation Multifunction Testers
AC voltage measurement | ||
Range | 500 V | |
Resolution | 0.1 V | |
Accuracy 45 Hz – 66 Hz | 0.8% + 3 | |
Input impedance | 360 kΩ | |
Overload protection | 660 V rms | |
Continuity testing (RLO) | ||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω | |
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |
Open Circuit Voltage | >4 V | |
Insulation resistance measurement (RISO) | ||
Test voltages | 50-100-250-500-1000 V | |
Accuracy of test voltage (at rated test current) | +10%, -0% | |
Test voltage | 50 V 100 V 250 V 500 V 1000 V |
|
Insulation resistance range | 20 MΩ / 50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ |
|
Resolution | 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ |
|
Test current | 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ |
|
Loop and line impedance (ZI) | ||
Range | 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω | |
Resolution | 0.001 Ω/ 0.01 Ω/ 0.1 Ω/1 Ω | |
Prospective earth fault current, PSC test | ||
Range | 1000 A / 10 kA (50 kA) | |
Resolution | 1 A / 0.1 kA | |
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |
RCD testing, RCD types tested | ||
RCD Type | AC¹ G²,S³ |
|
Model 1663 | A4, AC¹, G²,S³ | |
Model 1664 FC | A, AC, B5, S | |
Notes | ¹Responds to AC ²General, no delay ³Time delay ⁴Responds to pulsed signal ⁵Responds to smooth DC signal |
|
Tripping speed test (ΔT) | ||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR 10-30-100 mA |
|
Multiplier | x ½, x 1 x 5 VAR Mode Type B – 6, 60, 200 mA |
|
Measurement range | RCD Type G | 310 ms 50 ms |
RCD Type S | 510 ms 160 ms |
|
EV / RDC-DD | 6 mA – 10s 60 mA – 0.3s 200 mA – 0.1s |
|
Notes | ¹1000 mA type AC only 700 mA maximum type A in VAR mode The VAR Mode at RCD type B (smooth DC currents) generates the test currents acc. to IEC 62955 for RCD type A-EV or RDC-DD (6/60/200 mA and ramp <2 to 6 mA). |
|
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) | ||
Current range | 30% to 110% of RCD rated current¹ <2 mA to 6 mA smooth DC³ |
|
Step size | 10% of IΔN² Linear rising within 30 s |
|
Dwell time | RCD Type G | 300 ms/step |
RCD Type S | 500 ms/step | |
Measurement accuracy | ±5% | |
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B |
|
Notes | ¹30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B ²5% for Type B ³For RCD type A-EV/RDC-DD acc. to IEC 62955 |
|
Earth Resistance Test (RE) | ||
Range | 200 Ω / 2000 Ω | |
Resolution | 0.1 Ω / 1Ω | |
Frequency | 128 Hz | |
Output Voltage | 25 V | |
Phase Sequence Indication | ||
Icon | Phase Sequence indicator is active. | |
General Specifications | ||
Size (L x W x H) | 10 x 25 x 12.5 cm | |
Weight (incl. batteries) | 1.3 Kg | |
Battery size, quantity | Type AA, 6 ea. | |
Sealing | IP-40 | |
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |
Overvoltage | CAT III / 500V; CAT IV 300V | |
Performance | EN61557-1 to EN61557-7 and EN61557-10 |
Models: Fluke 1663 Installation Multifunction Tester
Includes:
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead