Fluke 1662 Multifunction Testers
- Comprehensive Testing Capabilities:
- Voltage and frequency measurement
- Resistance measurement
- Continuity testing
- Earth resistance measurement
- Loop impedance testing
- RCD testing (Type A and AC)
- Insulation resistance testing
- Polarity testing
- Phase rotation testing
- Advanced Features:
- RCD Testing: Ensures the proper functioning of RCDs.
- Intuitive User Interface: Easy to operate and navigate.
- Rugged and Durable Design: Built to withstand harsh conditions.
- Efficient Testing: Fast and efficient testing procedures.
- Description
- Additional information
- Specifications
- Models
Description
Description
The Fluke 1662 Multifunction Installation Tester is a reliable and efficient tool designed for electrical professionals. This versatile instrument offers a comprehensive range of testing capabilities to ensure the safety and compliance of electrical installations in residential, commercial, and industrial settings.
Key Features:
Comprehensive Testing Capabilities: The 1662 covers a wide range of essential tests, including:
- Voltage and frequency measurement
- Resistance measurement
- Continuity testing
- Earth resistance measurement
- Loop impedance testing
- RCD testing (including Type A and AC)
- Insulation resistance testing
- Polarity testing
- Phase rotation testing
Advanced Features:
- RCD Testing: The 1662 enables accurate testing of RCDs, including both Type A and AC, ensuring their proper functioning.
- Intuitive Interface: The user-friendly interface with a large, clear display simplifies operation and navigation.
- Rugged and Durable Design: Built to withstand harsh working conditions, the 1662 is designed for reliable performance in various environments.
- Efficient Testing: The 1662 offers fast and efficient testing procedures, saving time and effort.
Applications:
- Electrical Installations: Verifying the safety and compliance of new installations.
- Periodic Inspections: Conducting routine inspections to identify potential hazards and ensure ongoing safety.
- Fault Finding: Diagnosing electrical faults and troubleshooting issues.
- Maintenance and Repair: Supporting maintenance and repair activities.
Benefits:
- Enhanced Safety: By ensuring the correct functioning of electrical systems, the 1662 helps prevent accidents and electrical shocks.
- Increased Efficiency: The efficient testing procedures and user-friendly interface improve productivity.
- Accurate and Reliable Results: Precise measurements and advanced features ensure accurate and reliable test results.
- Compliance with Standards: The 1662 helps users comply with relevant electrical safety standards and regulations.
Overall, the Fluke 1662 is a powerful tool that empowers electrical professionals to perform efficient and accurate testing, ensuring the safety and reliability of electrical installations.
Additional information
Additional information
Brand | Fluke |
---|
Specifications
Specifications: Fluke 1662 Multifunction Testers
AC voltage measurement | ||
Range | 500 V | |
Resolution | 0.1 V | |
Accuracy 45 Hz – 66 Hz | 0.8% + 3 | |
Input impedance | 360 kΩ | |
Overload protection | 660 V rms | |
Continuity testing (RLO) | ||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω | |
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |
Open Circuit Voltage | >4 V | |
Insulation resistance measurement (RISO) | ||
Accuracy of test voltage (at rated test current) | +10%, -0% | |
Test voltage | 100 V 250 V 500 V 1000 V |
|
Insulation resistance range | 20 MΩ / 50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ |
|
Resolution | 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ |
|
Test current | 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ |
|
Loop and line impedance (ZI) | ||
Range | 10 Ω / 0.001 Ω / High current mΩ mode | |
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |
Prospective earth fault current, PSC test | ||
Range | 1000 A / 10 kA (50 kA) | |
Resolution | 1 A / 0.1 kA | |
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |
RCD testing, RCD types tested | ||
RCD Type | A4, AC¹, G², S³ | |
Notes | ¹Responds to AC ²General, no delay ³Time delay 4Responds to pulsed signal 5Responds to smooth DC signal |
|
Tripping speed test (ΔT) | ||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR 10-30-100 mA |
|
Multiplier | x ½, x 1 x 5 |
|
Measurement range | RCD Type G | 310 ms 50 ms |
RCD Type S | 510 ms 160 ms |
|
Notes | ¹1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. |
|
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) | ||
Current range | 30% to 110% of RCD rated current¹ | |
Step size | 10% of IΔN² | |
Dwell time | Type G | 300 ms/step |
Type S | 500 ms/step | |
Measurement accuracy | ±5% | |
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B ²5% for Type B |
|
Notes | ¹30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B |
|
Phase Sequence Indication | ||
Icon | Phase Sequence indicator is active. | |
General Specifications | ||
Size (L x W x H) | 10 x 25 x 12.5 cm | |
Weight (incl. batteries) | 1.3 (kg) | |
Battery size, quantity | Type AA, 6 ea. | |
Sealing | IP-40 | |
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |
Overvoltage | CAT III / 500V; CAT IV 300V | |
Performance | EN61557-1 to EN61557-7 and EN61557-10 |
Models
Models: Fluke 1662 Multifunction Testers
Includes:
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead