Fluke 1552a Stik Thermometer & Temperature Calibrator
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.05°C (±0.09°F) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -80 °C to 300 °C ( -112 °F to 572 °F)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Description
- Additional information
- Specifications
Description
The Fluke 1552A is a high-precision, intrinsically safe “Stik” thermometer designed for accurate temperature measurements in various industrial and field applications.
Key features and benefits:
- High accuracy: Delivers repeatable temperature measurements accurate to ±0.05°C over its full range.
- Intrinsically safe: Rated intrinsically safe for use in potentially explosive atmospheres, ensuring safe operation in hazardous environments.
- Portability and durability: Compact and rugged design makes it easy to transport and use in the field.
- Long battery life: Provides up to 300 hours of continuous operation on a single battery charge.
- Easy to use: Simple interface and intuitive operation make it easy to learn and use.
Applications:
- Calibration of temperature sensors and transmitters
- Process control
- Industrial maintenance
- Research and development
- Quality control
Overall, the 1552A is a reliable and accurate temperature measurement tool suitable for a wide range of applications, especially in hazardous environments.
In addition to the features mentioned above, the Fluke 1552A also offers:
A wider temperature range: Compared to the Fluke 1551A, the 1552A has a wider temperature range, typically from -80°C to 300°C, making it suitable for a broader range of applications.
Datalogging capabilities: Some models of the Fluke 1552A include datalogging capabilities, allowing users to record temperature readings over time.
Overall, the 1552A is a versatile and powerful tool for accurate and reliable temperature measurement in demanding environments.
Additional information
Brand | Fluke Calibration |
---|
Specifications: Fluke 1552a Stik Thermometer & Temperature Calibrator
Specifications | |
Temperature range | -80°C to 300°C (-112°F to 572°F) |
Accuracy (1 year) | ±0.05°C (±0.09°F) |
Temperature resolution | Selectable: 0.1, 0.01, 0.001 (default 0.01) |
Sample rate | Selectable: 0.5 seconds, 1 second, 2 seconds (default 1 second) |
Readout temperature coefficient | Add ±10 ppm/°C of full scale temperature from −10 °C to 18 °C and 28 °C to 50 °C |
Probe temperature coefficient | 0.00385 Ω/Ω/°C nominal |
Nominal probe resistance at 0 °C | 100 Ω |
Probe hysteresis | ±0.01°C |
Response time | Approximately 20 seconds |
Operating temperature range of readout | -10°C to 50°C (14°F to 122°F) |
Humidity range | 0% to 95% RH, non-condensing |
Storage temperature | -20°C to 60°C (-4°F to 140°F) |
Display units | °C, °F |
Sensor type | 100 Ω wire-wound PRT |
Sensor length | ≤ 30 mm |
Sensor position (from sheath tip) | 3 mm (0.1 in) |
Minimum immersion depth | Wet medium (liquid bath, thermowell with thermal compound) 70 mm (2.8 in) Dry medium (dry-well, thermowell without thermal compound) 120 mm (4.8 in) |
Maximum immersion depth | 75 mm (3 in) less than the total length. Make sure the last 75 mm of the probe, nearest to the internal electronics of the device, are not put into the heat source. |
Probe sheath material | Stainless steel |
Optional data logging1 | Up to 10,000 time-stamped readings stored to internal memory |
Logging intervals1 | 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds |
Damping | Moving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10) |
Communications | RS-232 stereo jack (access calibration parameters only) |
AC power | None |
DC power | 3-AAA alkaline batteries See Users Manual for approved batteries |
Battery life | Approximately 300 hours (12.5 days) of continuous operation with the backlight off. |
Battery save (auto-off) range | Selectable from 1 to 30 minutes or can be disabled |
Safety | IEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2 |
Electromagnetic compatibility | International: IEC 61326-1: Portable Equipment; IEC 61326-2-2; CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Size (readout only) | 125 mm x 62 mm x 35 mm (5 in x 2.5 in x 1.4 in) |
Probe Size | 6.35 mm x 305 mm (1/4 in x 12 in) |
Weight | 200 g (6.9 oz) |
Calibration (included) | NVLAP-accredited, NIST-traceable |
Characterization | ITS-90 |
1. See ordering information for optional data logging configurations |