Fluke 1502A/1504 Thermometer Readout
- 1502A: accuracy up to ±0.006 °C.
- 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
- 1502A: covers –200°C to 962°C
- 1504: covers 0 to 100°C
- Description
- Additional information
- Specifications
Description
The Fluke Calibration 1502A and 1504 are high-accuracy, multi-channel thermometer readouts designed for precise temperature measurements in various applications.
Key Features:
- High Accuracy: Both models offer exceptional accuracy, with the 1504 providing even higher accuracy than the 1502A.
- Multi-Channel Capability: Can simultaneously read multiple temperature sensors, increasing efficiency and reducing measurement time.
- Versatile: Compatible with a wide range of temperature sensors, including RTDs, thermistors, and thermocouples.
- Data Logging and Analysis: Many models offer data logging capabilities, allowing for recording and analysis of temperature data over time.
- User-Friendly Interface: Intuitive interfaces with clear displays make operation and data interpretation straightforward.
- Rugged and Durable: Built to withstand demanding environments and provide reliable performance in industrial settings.
Applications:
- Calibration Laboratories: Used for calibrating a wide range of temperature sensors and instruments.
- Research and Development: Accurate temperature measurements in scientific research and development.
- Industrial Processes: Monitoring and control of temperature in various industrial processes.
- Quality Control: Ensuring product quality and consistency through precise temperature monitoring.
The Fluke Calibration 1502A and 1504 are high-performance thermometer readouts that offer exceptional accuracy, versatility, and user-friendly features. They are essential tools for laboratories, calibration facilities, and industries requiring precise temperature measurements.
Key Differences:
Accuracy: The 1504 generally offers higher accuracy than the 1502A.
Features: The 1504 may include additional features such as more channels or advanced data logging capabilities depending on the specific model.
Additional information
| Brand | Fluke Calibration |
|---|
Specifications: Fluke Calibration 1502A/1504 Thermometer Readout
| Specifications | 1502A | 1504 |
| Temperature Range† | −200 °C to 962 °C (−328 °F to 1764 °F) | Any thermistor range |
| Resistance Range | 0 Ω to 400 Ω, auto-ranging | 0 Ω to 1 MΩ, auto-ranging |
| Probe | Nominal RTPW: 10 Ω to 100 Ω RTD, PRT, or SPRT |
Thermistors |
| Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 IPTS-68: R0, a, d, a4, and c4 Callendar-Van Dusen: R0, a, d, and b |
Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b |
| Resistance Accuracy (ppm of reading) |
0 Ω to 20 Ω: 0.0005 Ω 20 Ω to 400 Ω: 25 ppm |
0 Ω to 5 KΩ: 0.5 Ω 5 KΩ to 200 KΩ: 100 ppm 200 KΩ to 1 MΩ: 300 ppm |
| Temperature Accuracy† | ±0.004 °C at −100 °C ±0.006 °C at 0 °C ±0.009 °C at 100 °C ±0.012 °C at 200 °C ±0.018 °C at 400 °C ±0.024 °C at 600 °C |
±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.) |
| Operating Temperature Range | 16 °C to 30 °C | 13 °C to 33 °C |
| Resistance Resolution | 0 Ω to 20 Ω: 0.0001 Ω 20 Ω to 400 Ω: 0.001 Ω |
0 Ω to 10 KΩ: 0.01 Ω 10 KΩ to 100 KΩ: 0.1 Ω 100 KΩ to 1 MΩ: 1 Ω |
| Temperature Resolution | 0.001 °C | 0.0001 °C |
| Excitation Current | 0.5 and 1 mA, user selectable, 2 Hz | 2 and 10 µA, automatically selected |
| Measurement Period | 1 second | |
| Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) | |
| Probe Connection | 4-wire with shield, 5-pin DIN connector | |
| Communications | RS-232 serial standard IEEE-488 (GPIB) optional |
|
| Display | 8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters | |
| Power | 115 VAC (±10 %), 50/60 Hz, 1 A, nominal 230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify |
|
| Size (HxWxD) | 61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) | |
| Weight | 1.0 kg (2.2 lb.) | |
| Probes from Fluke Calibration | 5615, 5627, 5626, 5628, 5622 | 5640-44, 5610-65 |
| Calibration | ISO 17025-accredited calibration provided | |
| †Temperature ranges and accuracy may be limited by the sensor you use. | ||
Related Products
- Temperature control from 300°C to 1200°C
- 3-in-1 furnace with 9 unique modes
- Stability of ±0.1°C
- Radial uniformity of ±0.25°C @ 1200°C
- Axial uniformity of ±0.25°C @ 1200°C
- Dual-zone control
- Full HART field communicator
- Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
- Set point control by reference
- Self-calibration feature
- ISO 17025-accredited calibration w/data included
- Reference level performance in accuracy, stability and uniformity
- Quick to temperature
- Two-channel readout measures RTDs and TCs, and provides task documentation
- Full HART communicator (PC Option)
- Built in automatic annealing feature (ADT878-700 only)
- ISO 17025-accredited calibration w/data included
- Temperature control from 100°C to 1210°C
- Two models to choose from: Reference (ADT878) and Standard (ADT875)
- Display Accuracy of ±1.5°C (ADT878)
- 4 on-board measurement channels (PC option)
- Process calibrator option provides a multi-channel readout for TCs, switches and transmitters, including task documentation and HART communication
- ISO 17025-accredited calibration w/data included
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
- Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
- Scan up to 10 channels per second, great for high-speed applications.
- Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
- Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.
- Highly accurate thermo hygrometer and humidity monitor.
- Measure temperature to ± 0.125 °C and humidity to ± 1.5% on two channels.
- Offers networking capabilities via Ethernet or RS-232, connect multiple Fluke 1620s.
- Powerful logging and analysis tools, including the LogWare III software for real-time logging, data storage, and integration with MET/CAL® software.
- Accredited radiometric calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Operate in temperatures ranging from -200 °C to 160 °C.
- Accuracy of ± 0.05 °C.
- Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range.
- Unique probe seal prevents moisture ingress.
- Come with NVLAP-accredited calibration.
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity checks
- Powerful, easy-to-use, high-accuracy temperature calibrator
- Test and calibrate temperature sensors and transmitters
- Measures 4 to 20 mA loops and can provide loop power
- Measures RTDs, thermocouples, ohms, and volts
- Source/simulates thermocouples, RTDs, volts, and ohms
- Calibration of both temperature and pressure transmitters
- Measure/source/simulate mA loop parameters
- Measure and source mA, Volts DC, frequency, and resistance
- Built-in 24 V loop power supply
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
- Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement
- Complete pressure, temperature, and mA loop calibrator
- Troubleshoot and calibrate HART smart digital transmitters
- Create calibration procedures and automatically document results
- Temperature ranges from –15 °C to 350 °C.
- Two wells in each block for simultaneous comparison calibrations.
- The cold block is calibrated to within ±0.2°C with stability of ±0.05°C. The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C.
- Rugged, lightweight, and water-resistant enclosure.
- Accuracy to ±0.25°C and comes with an RS-232 interface.
- The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
- The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
- Features designed with user convenience and productivity in mind.
- Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
- With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
- Low-cost thermocouple furnace.
- NIST-traceable calibration included.
- RS-232 port standard
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
- Wide temperature range: –95 °C to 140 °C.
- Excellent accuracy
- Accuracy using built-in reference thermometer readout: ± 0.05 °C full range.
- Display accuracy: ± 0.2 °C full range.
- Best-in-class stability: ± 0.015 °C full range